Fujikura large core fiber - S series [Step index glass clad fiber for UV to VIS]
Model Name
Refractive Index Profile
Core / Cladding Material
Core / Cladding Diameter [μm]
Jacket Diameter [μm]
Attenuation [dB/km]
Coating / Jacket Material
NA
Operation Temperature [°C]
Minimum Bending Radius [mm] (Note)
S.200/220
Step Index
SiO2 (High-OH) / F-SiO2
200 / 220
900
≤200 (@300nm) ≤10 (@800nm)
Silicone / Polyamide
0.22
-20 to 60
44
S.400/440
400 / 440
1100
88
S.600/660
600 / 660
1400
132
S.800/880
800 / 880
1700
176
S.1000/1100
1000 / 1100
220
S.1500/1650
1500 / 1650
2400
330
S.2000/2100
2000 / 2100
3100
420
Notes:
- Minimum Bending Radius is long term bending radius (fibers placed in storage) - Other size for core diameter, cladding diameter, non-standard NA Fiber are available. - PFA, ETFE, FEP, Jacketed Fiber and Hard Polymer Cladding Fiber (HPCF) are also available.
- Our products support RoHS Directive.
- USP Class VI biocompatible
Fujikura large core fiber- SB series [Step index glass clad fiber for VIS to NIR]
Minimum Bending Radius [mm](Note)
S.200/220B
SiO2 (Low-OH)/ F-SiO2
≤10 (@850nm and @1064nm)
S.400/440B
S.600/660B
S.800/880B
S.1000/1100B
S.1500/1650B
S.2000/2100B
LargeCoreFiber_loss_spectru