Home / AFL Blog / January 2017 / Winter — Hard on Us and Test Equipment
Blog posts

Winter — Hard on Us and Test Equipment


By Don Allard, AFL Test and Inspection Commercial Manager

Cold weather is gripping the USA. Here in central New Hampshire, where AFL’s Test and Inspection operations is located, ski season is upon us with morning temps as low as -9°F (-22°C). It’s part of life in NH and sets a brisk step to your morning pace!

Extreme temperatures, whether cold or hot, affect both fiber optic technicians and their test equipment. Job sites may be thermally regulated, but technicians need to remember optical test equipment left in vehicles. Leaving equipment in a vehicle overnight exacerbates many issues.

Test measurements are impacted by thermal changes in the test instruments themselves. Thus, bringing test instruments stored overnight in a vehicle into a test environment of a different temperature can contribute to measurement errors. Think of equipment stored in a van overnight at -10°F (-23°C) entering into an equipment room kept around 65°F (18°C). This is a 75°F (41°C) temperature delta. You feel it when walking in and out of buildings.

Test equipment can take an hour or more to fully adjust and stabilize at new ambient temperature. Features like protective rubber boots and padded carry cases further insulate the instrument slowing down the thermal adjustment. An instrument may feel room temp to touch, but this is only the outside layer of the case. The temperature of important inside electronics and optics adjust slower.

Hot and cold weather must be considered. To improve your odds of getting accurate measurements, use setup time to your advantage. Bringing fiber optic or electronic test gear onto the job site must be a priority. Take the equipment out of carry cases immediately and spread test instruments out to let them begin adjusting to the new temperature and continue with the job setup.

Turn test instruments on 15 to 20 minutes ahead of time to continue the warm up and stabilization. For optical loss test kits, set references prior to taking measurements with the power meter and source in the test environment and after warm up. These simple planning steps will provide improved and more consistent test results.

Thank you to all the technicians who rush out into the cold to restore services. Power, broadband, cable, etc. fail when the worst of weather is upon us and you help minimize disruptions. We appreciate you!

Posted: 1/13/2017 by AFL | with 0 comment(s)
Filed under: AFL, Equipment, Test and Inspection, Winter
Comments
Blog post currently doesn't have any comments.
Leave comment



 Security code

Recent Posts

AFL FTTx/PON Products Receive Awards from BTR’s Diamond Technology Reviews

10/25/2021 10:18:29 AM | with 0 comments
Four AFL products were recognized by the 2021 Broadband Technology Report's (BTR) Diamond Technology Reviews.


Achieving a Connected World

10/13/2021 4:06:02 PM | with 0 comments
In this blog Seán Adam, Vice President, Market Strategy and Innovation at AFL, discusses what it will take to Achieve a Connected World, including a skilled workforce and a network that has flexibility, accessibility and expandability. 

Single-mode vs. Multimode

10/11/2021 3:05:33 PM | with 0 comments
This blog will explore the differences between single-mode and multimode fiber. 

Product Spotlight: Fujikura 90S+ Fusion Splicer

9/30/2021 9:33:42 AM | with 0 comments
Check out this blog to learn more about our Fujikura 90S+ Fusion Splicer with a key, new attribute: Active Fusion Control.


The Basic Structure of Optical Fiber

9/28/2021 8:04:51 AM | with 0 comments
This blog will explore the three main elements of optical fiber: the core, the cladding and the coating. 


Blog Tags

& 100G 12R 12S 2014 2015 2016 21s 22S 31S 41S 5G 62S 70R 70S 802.11ax 90R Access Networks accessibility accessories AccessWrap ADSS Aerial Aeros AFL AFL. Air Blown Fiber AlumaCore Aluminum and APEX APM-101 APM-102 APTA ASCEND ASIS Associates attenuation awards bandwidth Best Practices BICSI Bishop black Blog bluetooth Broadband BTR bus Cable cable deployment Cables Cable-Tec Cabling Careers Case Case Studies Catalogs Cell Tower Demarcation center Certification CGM Plus Rack Panel CI&M Innovators Award Cladding clean cleaner Cleaning Cleaning Supplies Cleaver cloud CO2 Lasers Coating collaboration collapsible Community Community Outreach compression Compression Accessories Computing Conductor Connect Connections Connectivity connector Connectors Co-ops copper Core Core-alignment Coronavirus Corporate Covid-19 C-RAN CT-30 CT50 CTIA customer experience CWDM dampers DAS data Data Center Data Centers Dead Ends demarcation Demonstration density Diamond Distribution Enclosure Donda DT Duel Dura-Line DWDM eABF Edge electric Enclosure end-to-end solutions Energy Engineer Enterprise Equipment ESB estimation expandability Expo Exterior Distribution Cabinet Facebook Fall Fall 2013 FAST SC FASTConnect FC Features Fiber Fiber Cleaver Fiber Connector Inspection Fiber Distribution fiber inspection Fiber Laser fiber management Fiber Optic Fiber Optic Cable Fiber Optic Intrusion Detection System Fiber Optic Training Fiber OpticTraining Fiber Prep Fiber Security Fiber Shaping Fiber Splicing fibre fibre optic cable field installable Field Splicer flexibility flexscan Flex-Span Flickr FlowScout FOCIS FOCIS Duel FOCIS Flex FOCIS Lightning FOCIS WiFi2 French FSM-100 FTTh FTTx Fujikura FuseConnect Fusion Fusion Splicer Fusion Splicers Fusion Splicing Gas generations Glass Processing global Google Governor Nikki Haley Grand Canyon Greenville Grounding Hardware high high-density High-Wire Walk HiTemp Hyperscale IDEAA IEEE infrastructure innovation inspect Inspection Instagram Install Installation Installing Instructions Integrated Solution International Sales Meeting Internet Interns IoT JMA Kit Laser Last Mile LAZERMaster LC Light Brigade LightLink LightWave LinkedIn live line LL-550 LL-550 & LL-580 enclosures LL580 LL-580 LMHD Loss LZM-100 M210 M310 Maintenance mechanical Metro Ethernet Metro-E MFIS MicroCore Mining mode Month of Service mount MPO MSOs Multi-Fiber Identification System multimode Network Networks new New Year NFPA Nik Wallenda Noyes NY OCS OEM of Oil One-Click OPGW Optic Optical Optical Connectivity Optical Sensing Optical Splicing optics OSP OSP MicroCore: LM200 & LMHD Series OTDR Outside Plant panel panels Paper PCS-100 Stripper Perimeter Security System PES Photonics Photonics West PhotonicsWest platform PM Splicing polarity Poli-Mod power Power Systems PREVAIL Procedures product Product Registration Products Provider providers rack Rail Railway Recoater Recruiting resource center Resources Reviews ribbon Rogue Rural Utilities Rusty Williams SB01 SC SCADA SCTE SCTE Cable-Tec SDN Selection Sensing service Services Sidewinder Rapid Cable Deployment System Silver Level Award single single circuit outage Single Lambda Single-mode SkyWrap Small-Cell Smart City Smart-Grid Smartphone Snapshot Social Software Defined Networking Solutions Spanish Specialty Specialty Splicer Spider Web Ribbon SpiderWeb SPIE Splice Enclosure Splicer Splicers Splicing ST Stockbridge Dampers Stranded Stainless Steel Cable Stream Streetcar Structured Cabling Study substation SuperMobility Support SWAGE Swaging swan SWAT SWFT System systems T&D T&I: technology Terminal termination Termination Instructions Test Test &Inspection Test and Inspection Testing Things Titan Tools trade show Trade Shows traffic Training Transit transition transmission Transportation trends TS100 Tube Tutorials Twitter Ultra HD Upstate Alliance utilities Utility ventilator VFI V-Groove vibration Video Videos Vodafone WDM WDM900 We Connect Webinar Website White White Paper White Papers White-Paper Wi-Fi Winter Wireless Women workflow Wrapping Wrapping Tube Cable WTC/SWR