MICON Accessories

Designed for use with type MA cable receptacles. Each size is machined with close tolerances for a specific cable size.
An uninsulated multi-outlet connector for connecting neutral uninsulated underground cables. Connector is made of high conductivity copper and completely hot tin dip coated.
An insulated multi-outlet connector for joining insulated underground cables to a common point. One pair of opposite outlets are unsealed and ready for cable insertion. All other outlets are sealed with rubber plugs vulcanized in position.
A compression type receptacle for securing cables electrically and mechanically to the MICON outlet positions.
An adapter for reducing the size of a compression outlet from nominal cable size down to #6 STR through a complete range of cables.
A MYPAR molded insulating sleeve for Use with Types LLA-2R123, LLA-2P123, and LLA-2PL123
A composition molded limiter terminal shell for use with limiter terminal assembly types LLA-2R123, LLA-2PL, LLA-2P123, and LLA-2PL123.
For Paper Insulated Cable, a cable terminal which serves as both a fuse and a connector. The fusible element has a time-current characteristic which will enable it to clear faults.
The limiter terminal for paper insulated cable acts as a cable terminal as well as a current limiting fuse. The fusible section is made to close tolerances.
A cable terminal which serves as both a fuse and connector. The fusible element has a time-current characteristic which will enable it to clear faults.
The limiter terminal acts as a cable terminal as well as a current limiting fuse. The fusible section is made to close tolerances to insure consistent conformity with the fusing timecurrent curves.
A high strength, high conductivity cable receptacle for securing cables electrically and mechanically to the MICON outlet positions.
A coupling for joining Micon connectors on end. The engaging feature of the coupling permits the outlets of each unit to assume any position about the center axis.
All Micon connectors are furnished with Mypar plugs, accommodating 25% of the outlets.
A multi-outlet pre-insulated connector to terminate four or more cables to the studs of network protectors or distribution transformers. The connector is completely insulated.
A multi-outlet pre-insulated connector to terminate a number of cables to the studs of network protectors or distribution transformers. The connector is completely insulated.
A multi-outlet insulated stud terminator for connecting insulated cables to the terminals of network protectors with a 2000 ampere rating.
An insulating sleeve to facilitate the taping of the MICON outlet.
A MYPAR molded type NRLA-1 insulating sleeve for use with types NLRA-P, NLRA-R, and NLRA-PL limiter link assemblies.
A cable coupler which serves as both a fuse and connector.
The long limiter link has a dual function of serving as a connecting coupler as well as a fuse. The fusible section determines the time-current characteristics of each size.
A cable coupler which serves as both a fuse and connector.
For use with Limiter Link Types NRLA-R3, NRLA-P3, and NRLA-PL3. An arc proof shell of molded composition provided with a system of cavities and heat confining barriers.
The limiter link has a dual function of serving as a connecting coupler as well as a fuse.
A straight line coupler for joining two cables on end. The symmetry and compact design render the connector easy to tape.
AFL's Dossert® line of connectors have been used underground almost since the first underground electrical distribution systems were installed. Early records show that Dossert connectors were used in underground installations dating from 1910.