Cookies Use on AFL Website We use cookies to give you the best online experience. By using our website you agree to our use of cookies in accordance with our privacy policy. Agree
Home / AU / Resources / Technical Information / Fibre Optic Attenuation and Loss Values

Fibre Optic Attenuation and Loss Values

Maximum Cable Attenuation (dB/km) as per AS/NZS 3080 (Table 26 P49)

MMF 50/125µm MMF 62.5/125µm SMF 9/125µm
850nm 1300nm 850nm 1300nm 1310nm 1550nm
3.5 1.5 3.5 1.5 1.0 1.0

 


Maximum Fusion Splice Loss (dB) as per AS/NZS 3080 (Table 46 P63)

MMF SMF
0.3 0.3

 


Maximum Channel Attenuation (dB) as per AS/NZS 3080 (Table 23 P44)

Channel MMF SMF
850nm 1300nm 1310nm 1550nm
OF-300 2.55 1.95 1.80 1.80
OF-500 3.25 2.25 2.00 2.00
OF-2000 8.50 4.50 3.50 3.50

 


ISO IEC 11801 maximum channel insertion loss for IEEE 802.3 10G Base-SR/SW applications on OM3 (50/125µm) fibre, OF-300 channel (Table F.3 P110) and AS/NZS 3080 (Table F.3 P98)

dB Wavelength
2.55 850nm

Note: Channel loss includes patching cables

 


Maximum Connector Insertion Loss (dB) as per AS/NZS ISO/IEC 14763.3 (P10 & P21)

Reference → Reference Reference → Random Random → Random
MMF SMF MMF SMF MMF SMF
≤0.10 ≤0.20 ≤0.30 ≤0.50 ≤0.75 ≤0.75