Durch die Kopplung von ROGUE®-Modulen mit Smart-Device-Apps ermöglicht die zum Patent angemeldete Architektur von AFL den Anwendern, ihre Testhardware direkt von den meisten Android-Geräten aus zu steuern.
5edfa262116b4307a3db666476920197
1 www.AFLglobal.com or (800) 321-5298, (603) 528-7780 Building Better Networks with ® | ® Test Suite ©2017, AFL, all rights reserved. RGM-TURBO-2000 Revision AA, 2017-04-18 Specifications are subject to change without notice. ROGUE OLTS/Certification Modules with TURBO App Features • Quad single-mode/multimode, Dual single-mode or Dual multimode • Hot-swappable into ROGUE cB1 or iB1 units • Use with aeRos cloud-based workflow management software • Integrated FOCIS Flex Inspection capability • Simultaneous, dual-wavelength, bi-directional loss and length testing through Dual Engine technology • Integrated Source, Power Meter and Visual Fault Locator (VFL) • Built-in Encircled Flux compliance Applications • Tier 1 certification testing of premise/enterprise networks • Dual-fiber, dual-wavelength, unidirectional or bi-directional OLTS testing • Multi-fiber testing: loss, length, ORL, certification with one push of a button • View results and generate reports anywhere, anytime using aeRos • Integrated multi-wavelength, bi-directional MPO/multi-fiber testing using optional multi-fiber switch Each ROGUE OLTS test module uses state-of-the-art technology to produce the most accurate results in the shortest amount of time. Modules contain bi-directional test ports as well as an optical power meter port and visual fault locator. All Multimode ports are Encircled Flux compliant as required by ANSI/TIA and ISO/IEC. By pairing ROGUE modules with smart device apps, AFL’s patent pending architecture enables users to control their test hardware directly from any Android smart device. ROGUE users can easily turn the OLTS solution into a full Tier 1 certifier simply by adding our TURBO Certification app. Test configurations and instructions are pushed from AFL’s aeRos cloud solution to the TURBO app to simplify the process for technicians. When the testing is complete, the results automatically and seamlessly synchronize with the cloud for real-time, on-site test data validation. No more waiting for the technician to return with a USB stick and manually transfer the data. With two bi-directional engines, you can even test both fibers in both directions on 2 wavelengths. All with the push of a button on your smart device. If your network consists of multi-fiber cables and MPO connectors, simply add our Multi-fiber Switch to the ROGUE platform to perform bi-directional, dual-wavelength, multi-fiber testing. AFL’s FOCIS Flex wireless inspection probe can also be added for integrated and seamless capture of fiber endface images. Apps available via Google play store.
2 www.AFLglobal.com or (800) 321-5298, (603) 528-7780 Building Better Networks with ® | ® Test Suite ©2017, AFL, all rights reserved. RGM-TURBO-2000 Revision AA, 2017-04-18 Specifications are subject to change without notice. Specifications a OLTS MULTIMODE SINGLE-MODE Emitter Type LED Laser Wavelengths 850 ±30 nm; 1300 ±20 nm 1310, 1550 ±20 nm Safety Class Class I FDA 21 CFR 1040.10 and 1040.11, IEC EN60825-1: 2007-03 Detector Type InGaAs InGaAs Launch Condition Encircled Flux Compliant b N/A Length Measurement Range 5 km 200 km (SMF28e) Power Measurement Range -3 to +60 dBm -3 to +60 dBm Output Power -24/-23 dBm, 62.5/50 μm -3 dBm, 9 μm Stability c ±0.1 dB over 1 hour ±0.15 dB over 8 hours ±0.1 dB over 1 hour ±0.15 dB over 8 hours Wave ID Transmit Yes Yes Tone Generation 330 Hz, 1 kHz, 2 kHz 330 Hz, 1 kHz, 2 kHz Input Connector Interchangeable connector adapter (LC standard, SC, ST, FC optional) OPTICAL POWER METER (OPM) Calibrated Wavelengths 850, 1300, 1310, 1490, 1550, 1625, 1650 nm Detector Type InGaAs PIN, 2 mm diameter Measurement Range +3 to -70 dBm Wave ID Automatically synchronizes and measures 1, 2 or 3 λ Wave ID combinations Range +3 to -40 dBm @ 850 nm; +3 to -50 dBm @ 1300, 1310, 1550 nm Tone Detect Auto-detects 270, 330 Hz; 1, 2 kHz tones; Accuracy ±5% @-10 dBm Linearity ±0.1 dB (-3 to -40 dBm); ±0.25 dB (-40 to -50 dBm) Measurement Units Power in dBm, nW, μW, mW; Loss in dB; 0.01 dB resolution VISUAL FAULT LOCATOR (VFL) Emitter Type Visible red laser, 650 ±20 nm Safety Class Class II FDA 21 CFR 1040.10 and 1040.11, IEC EN60825-1: 2007-03 Output Power (nominal) 0.8 mW into single-mode fiber Modes CW and 2 Hz flashing GENERAL Size 135 x 122 x 43 mm (5.4 x 4.8 x 1.7 in) Weight 0.4 kg (0.9 lb) Operating Temperature -18°C to +50°C, 0 to 95% RH (non-condensing) Storage Temperature -30°C, to +60°C, 0 to 95% RH (non-condensing) CE Safety & EMI/RFI EN61010-1; EMI/RFI: EN55011, EN61326-1, GR-196-CORE 4.5.1 RoHS 2011/65/EU Notes: a. All specifications valid at 23°C ±2°C (73.4°F ±3.6°F) unless otherwise specified. b. TIA-526-14-B,ISO/IEC 14763-3 and IEC 61280-4-1. c. After 15 minutes warm-up.
3 www.AFLglobal.com or (800) 321-5298, (603) 528-7780 Building Better Networks with ® | ® Test Suite ©2017, AFL, all rights reserved. RGM-TURBO-2000 Revision AA, 2017-04-18 Specifications are subject to change without notice. ROGUE Certification Kits Each ROGUE Certification kit includes two (2) of each: ROGUE cB1 or iB1 unit, battery, adjustable carry strap, power supply, carry case, kickstand. Each kit also includes kit-specific ROGUE Modules and Turbo Certification license(s) (see table below). All kits include (1) One-Click Cleaner SC/2.5 mm and switchable test port adapters and test accessories (see table below). ROGUE CERTIFICATION KITS CONTAINS (e.a.) AFL NO. ROGUE BASE ROGUE MODULES LICENSE REFERENCE TEST CORDS MATING ADAPTERS TEST PORT ADAPTERS OLS OPM cB1 iB1 QUAD SM/MM DUAL ENGINE SM 50 μ M MM SC SC SC LC SM MM Quad SM/MM 2 2 2 2 2 2 2 2 2 RGK-CERT01 Dual Engine SM and MM 2 2 2 4 4 4 4 8 4 4 RGK-CERT02 Dual Engine SM 2 2 2 4 2 4 2 2 RGK-CERT03 Dual Engine MM 2 2 2 4 2 2 2 2 RGK-CERT04 Quad SM/MM 2 2 2 2 2 2 2 2 2 RGK-CERT01B1 Dual Engine SM and MM 2 2 2 4 4 4 4 8 4 4 RGK-CERT02B1 Dual Engine SM 2 2 2 4 2 4 2 2 RGK-CERT03B1 Dual Engine MM 2 2 2 4 2 2 2 2 RGK-CERT04B1 ROGUE OLTS Mobile Apps Mobile Apps to configure, control and access results from your Android device are available for free download from Google Play. Ordering Information ROGUE OLTS Modules ROGUE OLTS modules must be installed in either a ROGUE cB1 or ROGUE iB1 unit. Each module comes with a ROGUE OLTS Basic license allowing the OLTS module to be used in a ROGUE cB1 or iB1 and enabling basic aeRos OLTS functionality. Each module includes SC connector adapter for the OLTS/OLS ports and universal 2.5 mm adapters for the VFL and OPM (if installed) ports. DESCRIPTION AFL NO. Module – Quad MM 850/1300 nm, SM 1310/1550 nm RG-1100-Q01 Module – MM 850/1300 nm, Dual Engine RG-1100-M01-D Module – SM 1310/1550 nm, Dual Engine RG-1100-S01-D International Sales and Service Contact Information Available at www.AFLglobal.com/Test/Contacts
Merkmale:
- Verfügbar für die meisten Android-Smart-Geräte
- Automatische Synchronisierung von Testkonfigurationen und -ergebnissen
- Einfach zu bedienende, vertraute Benutzeroberfläche
- Vor-Ort-Validierung von Testdaten in Echtzeit
Anwendungen:
- Tier-1-Tests von Hausnetzen
- Bidirektionale Prüfung auf 2 Verbindungen gleichzeitig
- Multifunktionstests: Verlust, Länge, ORL, Zertifizierung
- Integration mit Multi-Faser-Switch für MPO-OLTS-Tests
ROGUE®
OLTS/Zertifizierungs-App
DieApps von AFL'arbeiten nahtlos mit der aeRos® Cloud und der ROGUE Hardware-Plattform zusammen, um genau die Testmöglichkeiten zu schaffen, die für eine bestimmte Aufgabe benötigt werden.
Testkonfigurationen und -anweisungen werden von AFL’s aeRos-Cloud-Lösung auf eine Smart Device App übertragen, um den Prozess für Techniker zu vereinfachen. Die Techniker erhalten eine Benachrichtigung auf ihrem Smart Device und können die erforderlichen Tests durchführen. Nach Abschluss der Prüfung werden die Ergebnisse automatisch und nahtlos mit der Cloud synchronisiert. Sie müssen nicht mehr auf den Techniker warten, der mit dem USB-Stick zurückkommt und die Daten manuell überträgt. Stattdessen erhalten Sie sofortigen Zugriff auf die Testergebnisse.
Sie könnten mit einem einfachen OLTS-Testkit beginnen, das die Prüfung von Einzelfaserverlusten unterstützt. Durch Hinzufügen eines zweiten OLTS-Moduls können Sie nun zwei Fasern gleichzeitig prüfen. Und mit zwei bidirektionalen Engines können Sie sogar beide Fasern in beide Richtungen auf 2 Wellenlängen testen. Und das alles mit einem Tastendruck auf Ihrem Smartphone. ROGUE-Anwender können die OLTS-Lösung einfach durch Hinzufügen einer Zertifizierungs-App in einen vollwertigen Tier-1-Zertifizierer verwandeln. Das Hinzufügen zusätzlicher Funktionen ist so einfach wie das Herunterladen einer weiteren App.

FOCIS Flex Fiber Optic Connector Inspection System,FOCIS Lightning®2 Multi-Fiber Optic Connector Inspection System,CCT-Stecker Reinigungstipps,CLETOP ACT Adapter Reinigungsstäbchen,Cletop Reiniger für Lichtwellenleiterstecker,CLETOP Original-Serie Steckerreiniger,CLETOP S-Serie Reiniger für optische Stecker,FCC2 Enhanced Fiber Connector Cleaner and Preparation Fluid 10 oz Can,FCC2 Enhanced Formula Connector Cleaner and Preparation Fluid,FCC3 Debris Destroyer Faserreinigungsstift,FCP Field Portable Connector Cleaning Kits,FCP1 Stecker-Reinigungssets
1758