AFL’s FlowScout OLS8 optical light source represents the next generation of smart optical light sources. Built on the legacy of AFL/Noyes OLS series optical light sources, the FlowScout OLS8 provides a stable and accurate light source for use in enterprise LAN, data center, PON, and broadband networks.
b4ab32726df14c83b651d37485046628
AFLglobal.com 1 (800) 235-3423 © 2024, AFL, all rights reserved. OLS8-00-2000 Revision AC 2024-10-31 Specifications are subject to change without notice. Test and Inspection FlowScout ® OLS8 Optical Light Source 1 AFL’s FlowScout OLS8 optical light source represents the next generation of smart optical light sources. Built on the legacy of AFL/Noyes OLS series optical light sources, the FlowScout OLS8 provides a stable and accurate light source for use in enterprise LAN, data center, PON, and broadband networks. Intuitive operation: With a simple-to-use color touchscreen interface, fiber technicians can quickly set-up, test, validate, and document installed fiber plant, as well as perform troubleshooting as needed. Wave ID for reduced test time and errors: In the Wave ID mode, the OLS8 encodes each wavelength with a unique Wave ID code. When used with a Wave ID capable power meter, such as OPM8, the pair can test up to three wavelengths simultaneously reducing test time and eliminating wavelength-setting errors. The light source also offers CW mode (continuous output - no encoding) and supports test Tone generation (270 Hz, 330 Hz, 1 kHz, 2 kHz) to assist in troubleshooting. Flexible reporting: When used in conjunction with AFL’s FlowScout OPM8 power meter, test results may be transferred to a PC running FlexReports PC software. Illuminate your network and report in real-time using AFL’s FlowScout OLS8! Features • Large color touchscreen with icon-driven user interface • Rugged, dependable, and backed by industry-best 5-year warranty • Wave ID generation for reduced test time and user errors • Field-replaceable connector adapters for maximum flexibility • AFL’s FlexReporter ™ Test Results Manager integration (via OPM8) Applications • Enterprise LAN and Data Center fiber networks • FTTH PON networks • High power broadband and DWDM systems testing • Multimode and single-mode fiber networks
2 AFLglobal.com 1 (800) 235-3423 © 2024, AFL, all rights reserved. OLS8-00-2000 Revision AC 2024-10-31 Specifications are subject to change without notice. Test and Inspection FlowScout ® OLS8 Optical Light Source 2 Field-replaceable output adapter Field-replaceable output adapters enable access for inspection and cleaning of optical ports and supports multiple connector styles. Large color display Large color touchscreen, visible in direct sun - light, displays a simple to use user interface. Clear test parameter setup Intuitive, quick, and simple set-up for seamless testing, validation, and reporting. Durable design for field use Rugged design backed by industry-best 5-year warranty. Clear Home Screen Test Results Transfer to FlexReports PC Software Select Source Mode Select Wavelength General Settings FlexReporter ™ Suite OPM8 OLS8 Product Highlights User Interface Highlights Battery Operated Handheld Icon-driven Interface Comprehensive Reporting (With OPM) USB Power Port / Software Upgrades
AFLglobal.com 1 (800) 235-3423 © 2024, AFL, all rights reserved. OLS8-00-2000 Revision AC 2024-10-31 Specifications are subject to change without notice. Test and Inspection FlowScout ® OLS8 Optical Light Source 3 Specifications (a), (b) Optical Model OLS8-QUAD (MM Optical Port) OLS8-QUAD (SM Optical Port) OLS8-SM (Single Port) OLS8-XGS (Single Port) Wavelength 850 ±30 nm 1300 ±20 nm 1310 ±20 nm 1550 ±20 nm 1310 ±20 nm 1550 ±20 nm 1310 ±20 nm 1550 ±20 nm 1490 ±20 nm Spectral Width 45 nm (typ.) 120 nm (typ.) 5 nm (max) Emitter Type LED Laser Safety Class Class I FDA 21 CFR 1040.10 and 1040.11, IEC 60825-1: 2007-03 Output Power ≥-22 dBm, 50 μm multimode -1 dBm, 9 μm single-mode Output Stability ±0.1 dB over 8 hours (after 5 minutes warm-up) ±0.05 dB over 1 hour (after 15 minutes warm-up) (e) ±0.1 dB over 8 hours (after 15 minutes warm-up) Tone Output 270 Hz, 330 Hz, 1 kHz, 2 kHz Wave ID Supports AFL Wave ID General Available Adapters SC FC, ST, LC Power 120/240 VAC input; 5VDC @2A output to USB-C Battery User replaceable Li-Pol; IEC 62133-2:2017 and UN38.3 certified Operating Time (typical) (c) 10 hours continuous use Recharge Time (d) ≤3 hours Data Interfaces USB-C Operating Temperature -10 °C to +50 °C, 95% RH (non-condensing) Storage Temperature -30 °C to +60 °C, 95% RH (non-condensing) IP Rating IP54 Shock & Vibration Withstands 1 m drop test on all 6 sides Data Storage Non-volatile memory for field-updateable software and results storage Display 3.5 in. color backlit LCD; capacitive touchscreen; 320 X 480 pixels Size (H x W x D) 14.0 x 8.1 x 3.3 cm (5.5 x 3.2 x 1.3 in) Weight ≤300 g (≤0.66 lb) Calibration N.I.S.T. traceable;≥ 3 years between required re-calibration Warranty 5 years Notes: a. All specifications valid at 25°C unless otherwise specified. b. All OLS models are equipped with SC/UPC port as standard. c. Operating conditions: 60 tests in 20 minutes, then auto-off; repeat each hour. Display backlight at minimum brightness. d. Charging time data is provided for USB-C 2A charger. e. OLS8-Quad output stability specs when using APC connectors.
4 AFLglobal.com 1 (800) 235-3423 © 2024, AFL, all rights reserved. OLS8-00-2000 Revision AC 2024-10-31 Specifications are subject to change without notice. Test and Inspection FlowScout ® OLS8 Optical Light Source 4 Ordering Information AFL NO. Emitter Type Output Ports Output Wavelengths (nm) 850 1300 1310 1490 1550 OLS8-SM DUAL Laser 1 OLS8-QUAD LED + Laser 2 OLS8-SM XGS Laser 1 All OLS8 models include protective rubber boot, SC/UPC adapter, rechargeable Li-Pol battery, carry case and data + power cord. Test jumpers and connector adapters are required for operation (purchased separately). Test jumpers with a variety of connector styles and fiber types and adapter caps for most common connectors may be purchased from AFL. AFL NO. Description OLS8-SL2-BAS FlowScout OLS8-SM DUAL (1310/1550 nm) Basic Kit. Includes: FlowScout OLS8-SM DUAL light source, AC charger and power cable, quick reference guide, and soft carry case. OLS8-SL4-BAS FlowScout OLS8-QUAD (850/1300/1310/1550 nm) Basic Kit. Includes: FlowScout OLS8-QUAD light source, AC charger and power cable, quick reference guide, and soft carry case. OLS8-SL7-BAS FlowScout OLS8-SM XGS (1310/1490/1550 nm) Basic Kit. Includes FlowScout OLS8-SM XGS light source, AC charger and power cable, quick reference guide, and soft carry case. Connector Adapters AFL NO. Description 2900-63-0007MR SC/UPC Adapter for FlowScout OLS8 2900-63-0008MR LC/UPC Adapter for FlowScout OLS8 2900-63-0009MR ST/UPC Adapter for FlowScout OLS8 2900-63-0010MR FC/UPC Adapter for FlowScout OLS8 Recommended Products FlowScout OPM8 Optical Power Meter • Rapid pass/fail analysis based on user-set limits • Wave ID functionality for accuracy and reduced test time • Internal test results storage • Test results transfer via USB, Bluetooth, and free FlexApp • Reports generation using AFL’s FlexReporter ™ OFI-BIPM Optical Fiber Identifier • World-class signal sensitivity • Trigger lock, positive stop for optimum detection • Integrated optical power meter option
AFLglobal.com 1 (800) 235-3423 © 2024, AFL, all rights reserved. OLS8-00-2000 Revision AC 2024-10-31 Specifications are subject to change without notice. Test and Inspection FlowScout ® OLS8 Optical Light Source 5 Qualificati ons Category Regulation/ Standard Qualification CE Marking EU Compliant to relevant EU Directives on health, safety, and environmental protection, and certified with CE marking UKCA Marking UK Compliant to relevant UK Directives on health, safety, and environmental protection, and certified with the UKCA marking Safety/EMC/EMI IEC Compliant to IEC 61010-1 for safety requirements for electrical equipment EN Compliant to EN 61010-1 for safety requirements for electrical equipment IEC Compliant to IEC 61326-1 for EMC requirements for electrical equipment EN Compliant to EN 61326-1 for EMC requirements for electrical equipment EN Compliant to EN 55011 for EMC requirements for industrial, scientific and medical equipment FCC Compliant to code of federal regulations FCC 47 CFR 15 on unlicensed transmissions FDA Compliant to code of federal regulations FDA 21 CFR 1040.10 and 1040.11 on laser products IEC Compliant to IEC 60825-1 for safety of laser products RoHS EU Compliant to EU regulations Directive 2011/65/EU (RoHS 2) and Directive 2015/863 (RoHS 3) Test Method TIA Compliant to TIA-568.3-E for test and measurement requirements for optical fiber cabling and components * IEC Compliant to IEC 11801 for test and measurement requirements for optical fiber cabling for use within premises * EN Compliant to EN 50173 for test and measurement requirements for optical fiber cabling for use within premises * AS/NZS Compliant to AS/NZS 3080 for test and measurement requirements for optical fiber cabling for use within premises * TIA Compliant to TIA-526-7 for test procedures for installed optical fiber cable plant TIA Compliant to TIA-526-14 for test procedures for installed optical fiber cable plant * IEC Compliant to IEC 14763-3 for systems and methods for the inspection and testing of installed optical fiber cabling * AS/NZS Compliant to AS/NZS 14763.3 for systems and methods for the inspection and testing of installed optical fiber cabling * IEC Compliant to IEC 61280-4-1 for test procedures for installed optical fiber cable plant * IEC Compliant to IEC 61280-4-2 for test procedures for installed optical fiber cable plant * A complementary encircled flux mode conditioner may be needed to comply with encircled flux launch conditions for testing multimode optical fiber cabling and components. Contact Sales@AFLglobal.com to schedule a demonstration or learn how to buy. Visit www.AFLglobal.com/Test to learn more about OLS8 series light sources. International Sales and Service Contact Information available at www.AFLglobal.com/Test/Contacts .
Features:
- Large color touchscreen with icon-driven user interface
- Rugged, dependable, and backed by an industry-best 5-year warranty
- Wave ID generation for reduced test time and user errors
- Field-replaceable connector adapters for maximum flexibility
- AFL’s FlexReporter™ Test Results Manager integration (via OPM8)
Applications:
- Enterprise LAN and Data Center fiber networks
- FTTH PON networks
- High power broadband and DWDM systems testing
- Multimode and single-mode fiber networks
AFL’s FlowScout OLS8 optical light source represents the next generation
of smart optical light sources. Built on the legacy of AFL/Noyes OLS series
optical light sources, the FlowScout OLS8 provides a stable and accurate light
source for use in enterprise LAN, data center, PON, and broadband networks.
Intuitive operation: With a simple-to-use color touchscreen
interface, fiber technicians can quickly set up, test, validate, and document
installed fiber plant, as well as perform troubleshooting as needed.
Wave ID for reduced test time and errors: In the Wave ID
mode, the OLS8 encodes each wavelength with a unique Wave ID code. When used
with a Wave ID capable power meter, such as OPM8, the pair can test up to
three wavelengths simultaneously reducing test time and eliminating
wavelength-setting errors. The light source also offers CW mode (continuous
output - no encoding) and supports test Tone generation (270 Hz, 330 Hz, 1
kHz, 2 kHz) to assist in troubleshooting.
Flexible reporting: When used in conjunction with AFL’s
FlowScout OPM8 power meter, test results may be transferred via Bluetooth to a
mobile iOS or Android device running AFL’s free FlexApp software.
FlexApp can automatically transfer results to AFL’s FlexReporter™
cloud for subsequent analysis, editing, and reports generation with
FlexReports PC software. FlexApp users may also share transferred results via
email or other cloud-sharing services. Illuminate your network and report in
real-time using AFL’s FlowScout OLS8!
Ordering Information
|
AFL NO.
|
Emitter Type
|
Output Ports
|
Output Wavelengths
|
|
|
850
|
1300
|
1310
|
1490
|
1550
|
|
OLS8-SM DUAL
|
Laser
|
1
|
|
|
•
|
|
•
|
|
OLS8-QUAD
|
LED + Laser
|
2
|
•
|
•
|
•
|
|
•
|
|
OLS8-SM XGS
|
Laser
|
1
|
|
|
•
|
•
|
•
|
|
AFL NO.
|
DESCIPTION
|
|
OLS8-SL2-0001MR
|
FlowScout OLS8-SM DUAL (1310/1550 nm) Basic Kit.
Includes: FlowScout OLS8-SM DUAL light source, AC charger and power
cable, quick reference guide, and soft carry case.
|
|
OLS8-SL4-0001MR
|
FlowScout OLS-QUAD (850/1300/1310/1550 nm) Basic Kit.
Includes: FlowScout OLS8-QUAD light source, AC charger and power
cable, quick reference guide, and soft carry case.
|
|
OLS8-SL7-0001MR
|
FlowScout OLS8-SM XGS (1310/1490/1550 nm) Basic Kit.
Includes FlowScout OLS8-SM XGS light source, AC charger and power
cable, quick reference guide, and soft carry case.
|
All OLS8 models include protective rubber boot, SC/UPC adapter, rechargeable
Li-Pol battery, carry case and data + power cord. See our
Buyers Guide
for complete details.

OLS Series Light Sources,Test Port Adapters,FlowScout® SE100 Single-Ended Test Set