AFL’s FlowScout MPO OLTS is the industry’s first true 16-fiber Tier I OLTS tester that supports testing of all multi-fiber AND duplex connectors, enabling much faster test time.
412d854d4c5748d581d84281c08e18aa,2d6219b67b3b4ccfbd4cb3226f97b3ea
AFLglobal.com 1 (800) 235-3423 © 2024, AFL, all rights reserved. MFLT-00-2000 Revision AA 2024-10-22 Specifications are subject to change without notice. Test and Inspection FlowScout ® MPO OLTS Test Set 1 AFL’s FlowScout MPO OLTS is the industry’s first true 16-fiber Tier I OLTS tester that supports testing of all multi-fiber AND duplex connectors, enabling much faster test time. Extremely fast testing: The FlowScout MPO OLTS test set provides significant time savings cutting testing phase in half. It streamlines the workflow with fewer steps and enables 16-fiber testing in just 6 seconds per port in a single pass. Highly accurate results and simple operation: The test set design is based on a precise and extremely accurate testing technology to ensure correct verification and validation of links. A simple to navigate icon-based user interface allows technicians to quickly set-up, test, validate, and document fiber networks. The FlowScout MPO OLTS measures and automatically evaluates pass/fail loss against industry or user-set limits. The large color touchscreen displays detected power levels with color-coded pass/fail indications. All-in-One solution: The FlowScout MPO OLTS is a pair of hand-held testers designed to support native multi-fiber as well as duplex connector testing using a single test set. Utilizing the integrated duplex tester, it offers the same workflow for testing duplex links. No need for a separate equipment or learning new workflow for duplex connector testing. One tester operates as an optical light source and the matching tester operates as an optical power meter, offering the same workflow for testing native multi-fiber as well as duplex connections. Single reporting platform for multi-fiber and duplex documentation: Measured pass/fail limits and status may be stored in the internal memory for download via Bluetooth or USB. Using AFL’s free FlexApp on iOS or Android mobile device, test results may be wirelessly transferred to AFL’s FlexReporter ™ cloud for subsequent analysis, editing, and reports generation with FlexReports PC software. Features • Industry’s first native 16-fiber Tier 1 OLTS tester • Single test set for multi-fiber and duplex fiber testing • Extremely fast and accurate pass/fail analysis • Certification to industry standards and custom test limits • Large color touchscreen with icon-driven user interface • Single reporting platform - AFL’s FlexReporter ™ Test Results Manager Applications • Tier I Certification of Hyperscale data centers • Enterprise LAN and data center fiber networks • Multi-tenant data centers
AFLglobal.com 1 (800) 235-3423 © 2024, AFL, all rights reserved. MFLT-00-2000 Revision AA 2024-10-22 Specifications are subject to change without notice. Test and Inspection FlowScout ® MPO OLTS Test Set 2 True 16-fiber Tier I OLTS tester Industry’s first – Supports testing of all multi- fiber AND duplex connectors, enabling much faster test time! Fast and accurate pass/fail analysis Designed on a precise and extremely accurate testing technology to ensure highly accurate verification and validation of fiber links Significantly reduced test time Simplified workflow with fewer steps enables 16-fiber testing in just 6 seconds per port in a single pass All-in-one solution A single test set and a single reporting platform for native multi-fiber as well as duplex connector testing Test Results Transfer to FlexReports PC Software User Interface Highlights Product Highlights Comprehensive Reporting USB Power Port / Software Upgrades Effortless Operation Hand-held Tester Simplified workflow with fewer steps Custom Test Setups MPO and Duplex Jumpers Referencing
AFLglobal.com 1 (800) 235-3423 © 2024, AFL, all rights reserved. MFLT-00-2000 Revision AA 2024-10-22 Specifications are subject to change without notice. Test and Inspection FlowScout ® MPO OLTS Test Set 3 Specifications a,b Optical Power Meter MPO Power Meter Duplex Power Meter Optical Interface Shuttered MPO-16 pinned Interchangeable connector adapter (LC standard) Detector Type InGaAs InGaAs Calibrated Wavelengths 1310 nm, 1550 nm 1310 nm, 1550 nm Power Measurement Range -50 to +3 dBm -60 to +3 dBm Accuracy ±5% @ -10 dBm ± 5% @ -10 dBm Linearity ±0.15 dB ± 0.15 dB Measurement Units dB, dBm dB, dBm Display Resolution 0.01 dB 0.01 dB Storage Capacity 10,000 results 10,000 results Length Measurement Range Up to 25 km under certain conditions Up to 25 km under certain conditions Warm Up Time 0 minutes 0 minutes Length Measurement Accuracy ±1 m ±1% of length ±1 m ±1% of length Calibration Period 3 years 3 years Light Source MPO Light Source Duplex Light Source Optical Interface Shuttered MPO-16 pinned Interchangeable connector adapter (SC standard) Source Type Laser Laser Safety Class Class I Class I Wavelengths 1310 ±20 nm, 1550 ±20 nm 1310 ±20 nm, 1550 ± 20 nm Spectral Width <5 nm <5 nm Output Power -9 dBm typical @ 1310 nm, -4 dBm typical @ 1550 nm -4 dBm typical Stability ±0.1 dB over 1 hour (after 15 minutes warm-up) ±0.15 dB over 8 hours (after 15 minutes warm-up) ±0.1 dB over 1 hour (after 15 minutes warm-up) ±0.15 dB over 8 hours (after 15 minutes warm-up) Warm-Up time 15 minutes 15 minutes OLTS System MPO OLTS System Duplex OLTS System Test time 6 seconds (16 fibers) 2 secconds General Size 22 x 11 x 5.5 cm (8.5 x 4.5 x 2.2 in) Weight 0.9 kg (2.0 lb) Screen 5" capacitive color touchscreen Interface Bluetooth 5.1 BLE Power and Data Transfer USB-C Operating Temperature -10 °C to +50 °C, 0 to 90 % RH (non-condensing) Storage Temperature -20 °C to +60 °C, 0 to 90 % RH (non-condensing) Power Rechargeable Li-Ion or AC power adapter Battery Life >8 hours continuous testing Notes: a. All specifications valid at 23°C ± 2°C unless otherwise specified. b. Accuracy measured at 25 ºC and -10 dBm per N.I.S.T. standards. c. Under reference conditions at calibrated wavelengths, -5 to +45 °C
AFLglobal.com 1 (800) 235-3423 © 2024, AFL, all rights reserved. MFLT-00-2000 Revision AA 2024-10-22 Specifications are subject to change without notice. Test and Inspection FlowScout ® MPO OLTS Test Set 4 FlowScout MPO OLTS Kits AFL NO. Description MFLT-MMC-16 FlowScout MPO OLTS Kit for Testing MMC-16 Fiber Links MFLT-MPO-12 FlowScout MPO OLTS Kit for Testing MPO-8/-12 Fiber Links MFLT-MPO-16 FlowScout MPO OLTS Kit for Testing MPO-16 Fiber Links Recommended Products FOCIS Lightning2 (Multi-Fiber Connector Inspection • Self-contained, tether-free, hand-held inspection solution • Auto-focus an d auto-centering for fast, easy inspection • IEC, IPC and user-defined pass/fail analysis • FOCIS Lightning2: extremely fast multi-fiber auto-analysis for datacom and tele com inspection applications One-Click® Cleaner MPO / MPO-16 • Ideal for Data Centers and high density optical networks • Designed to work on MTP®/MPO multi-fiber connectors • Cleans connectors on jumpers and in adapters Qualificati ons Category Regulation/ Standard Qualification CE Marking EU Compliant to relevant EU Directives on health, safety, and environmental protection, and certified with CE marking UKCA Marking UK Compliant to relevant UK Directives on health, safety, and environmental protection, and certified with the UKCA marking Safety/EMC/EMI IEC Compliant to IEC 61010-1 for safety requirements for electrical equipment EN Compliant to EN 61010-1 for safety requirements for electrical equipment IEC Compliant to IEC 61326-1 for EMC requirements for electrical equipment EN Compliant to EN 61326-1 for EMC requirements for electrical equipment EN Compliant to EN 55011 for EMC requirements for industrial, scientific and medical equipment FCC Compliant to code of federal regulations FCC 47 CFR 15 on unlicensed transmissions RoHS EU Compliant to EU regulations Directive 2011/65/EU (RoHS 2) and Directive 2015/863 (RoHS 3) Test Method TIA Compliant to TIA-568.3-E for test and measurement requirements for optical fiber cabling and components IEC Compliant to IEC 11801 for test and measurement requirements for optical fiber cabling for use within premises EN Compliant to EN 50173 for test and measurement requirements for optical fiber cabling for use within premises AS/NZS Compliant to AS/NZS 3080 for test and measurement requirements for optical fiber cabling for use within premises TIA Compliant to TIA-526-7 for test procedures for installed optical fiber cable plant TIA Compliant to TIA-526-14 for test procedures for installed optical fiber cable plant IEC Compliant to IEC 14763-3 for systems and methods for the inspection and testing of installed optical fiber cabling AS/NZS Compliant to AS/NZS 14763.3 for systems and methods for the inspection and testing of installed optical fiber cabling IEC Compliant to IEC 61280-4-1 for test procedures for installed optical fiber cable plant IEC Compliant to IEC 61280-4-2 for test procedures for installed optical fiber cable plant Generic Requirement IEC Compliant to IEC 61315 for requirements on calibration of fiber optic power meters Contact Sales@AFLglobal.com to schedule a demonstration or learn how to buy. Visit www.AFLglobal.com/Test to learn more about OPM8 optical power meters. International Sales and Service Contact Information available at www.AFLglobal.com/Test/Contacts . Test Cord Kits AFL NO. Description MFLT-MMC-16-CBL MMC-16 Test Cords for FlowScout MPO OLTS Kit MFLT-MPO-12-CBL MPO-8/-12 Test Cords for FlowScout MPO OLTS Kit MFLT-MPO-16-CBL MPO-16 Test Cords for FlowScout MPO OLTS Kit Ordering Information
Features:
- Industry’s first native 16-fiber Tier 1 OLTS tester
- Single test set for multi-fiber and duplex fiber testing
- Extremely fast and accurate pass/fail analysis
- Certification to industry standards and custom test limits
- Large color touchscreen with icon-driven user interface
- One reporting platform - AFL’s FlexReporter™ Test Results Manager
- Singlemode fiber testing at 1310/1550 nm
Applications:
- Tier I Certification of Hyperscale data centers
- Enterprise LAN and data center fiber networks
- Multi-tenant data centers
AFL’s FlowScout MPO OLTS is the industry’s first true 16-fiber Tier I OLTS tester that supports singlemode fiber testing of all multi-fiber AND duplex connectors, enabling much faster test time.
Extremely fast testing: The FlowScout MPO OLTS test set provides significant time savings cutting testing phase in half. It streamlines the workflow with fewer steps and enables 16-fiber testing in just 6 seconds per port in a single pass.
Highly accurate results and simple operation: The test set design is based on a precise and extremely accurate testing technology to ensure correct verification and validation of links. A simple to navigate icon-based user interface allows technicians to quickly set-up, test, validate, and document fiber networks. The FlowScout MPO OLTS measures and automatically evaluates pass/fail loss against industry or user-set limits. The large color touchscreen displays detected power levels with color-coded pass/fail indications.
All-in-One solution: The FlowScout MPO OLTS is a pair of hand-held testers designed to support native multi-fiber as well as duplex connector testing using a single test set. Utilizing the integrated duplex tester, it offers the same workflow for testing duplex links. No need for a separate equipment or learning new workflow for duplex connector testing. One tester operates as an optical light source and the matching tester operates as an optical power meter, offering the same workflow for testing native multi-fiber as well as duplex connections.
Single reporting platform for multi-fiber and duplex documentation: Measured pass/fail limits and status may be stored in the internal memory for download via Bluetooth or USB. Using AFL’s free FlexApp on iOS or Android mobile device, test results may be wirelessly transferred to AFL’s FlexReporter™ cloud for subsequent analysis, editing, and reports generation with FlexReports PC software.

FlowScout™ OLS8 Optical Light Source,FlowScout™ OPM8 Optical Power Meter,FlowScout™ PON Optical Power Meter,FlowScout® Optical Loss Test Kits,FlowScout® SE100 Single-Ended Test Set ,Encircled Flux EF Compliant Light Sources and Test Kits,Optical Loss Test Kits SLP56D SLP5