Le connecteur en té de la série 5500HT est une chute permanente spécialement conçue pour les conducteurs ACSS/TW. Il est fabriqué à partir d'un aluminium spécialement trempé qui transfère un courant élevé et dissipe plus efficacement la chaleur accrue.
www.AFLglobal.com or 800-866-7385 HiTemp ® © 2003, AFL, all rights reserved. PP-3-00748, Revision 3, 9.13.16 Specifications are subject to change without notice. 328 ACSS/TW ACCESSORIES Step 1: Determine Run Catalog Number Determine the run catalog number based on the conductor being used Step 2: Determine Branch Catalog Number Determine the branch catalog number based on the conductor being used Step 3: Assemble Catalog Number Example: For a Tee Connector with a run conductor of 954 Cardinal ACSS/ TW Conductor and a branch conductor of 1192 5 Gracklel ACSS/ TW Conductor, the complete catalog number is: 5530.3-36.144HT The 5500HT Series Tee Connector is a permanent drop specifically designed for ACSS/TW conductors It is fabricated from a specially tempered aluminum that will transfer elevated current and dissipate increased heat more efficiently The run portion incorporates an improved design of interlocking extrusions, providing a permanent grip on the conductor when compressed The branch portion of the tee connector is designed for limited tension use, maintaining a minimum of 40% of the ASTM rated strength of the conductor For die sizes 30AH and above, the end tapers of the compression portions of all compression accessories are supplied with a high voltage finish Ordering Instructions HiTemp Tee Connector—Open Run for ACSS/TW Conductor, 5500HT Series Branch Catalog Number Run Catalog Number + Notes: 1 HiTemp AFL Filler Compound (AFCHT) Requirements are on page 340 2 Installation Instructions for Tee Connectors are on page 351
www.AFLglobal.com or 800-866-7385 HiTemp ® © 2003, AFL, all rights reserved. PP-3-00748, Revision 3, 9.13.16 Specifications are subject to change without notice. 329 ACSS/TW ACCESSORIES HiTemp Tee Connector—Open Run for ACSS/TW Conductor, 5500HT Series (cont.) PARTIAL CATALOG NUMBER CONDUCTOR DIE SIZE WEIGHT RUN LENGTH A BRANCH LENGTH B CODE NAME SIZE TYPE STRANDING DIAMETER RUN BRANCH KCMIL AL/ST IN LBS KG IN MM IN MM 5520 3 -20 781HT Oriole/ACSS/TW 336 4 23 18/7 0 693 20AH 2 5 1 1 22 5 569 11 6 294 5524 3 -24 938HT Flicker/ACSS/TW 477 0 13 18/7 0 776 24AH 3 9 1 8 23 5 594 12 3 310 5524 3 -24 938HT Hawk/ACSS/TW 477 0 16 18/7 0 789 24AH 3 9 1 8 23 5 594 12 3 310 5524 3 -24 938HT Hen/ACSS/TW 477 0 23 18/7 0 825 24AH 3 9 1 8 23 5 594 12 3 310 5524 3 -24 969HT Parakeet/ACSS/TW 556 5 13 18/7 0 835 24AH 3 8 1 7 23 5 594 12 3 310 5524 3 -24 969HT Dove/ACSS/TW 556 5 16 20/7 0 852 24AH 3 8 1 7 23 5 594 12 3 310 5524 3 -24 969HT Calumet/ACSS/TW 565 3 16 18/7 0 858 24AH 3 8 1 7 23 5 594 12 3 310 5524 3 -24 969HT Mohawk/ACSS/TW 571 7 13 18/7 0 846 24AH 3 8 1 7 23 5 594 12 3 310 5527 3 -27 106HT Rook/ACSS/TW 636 0 13 19/7 0 890 27AH 5 5 2 5 26 3 664 12 8 325 5527 3 -27 106HT Grosbeak/ACSS/TW 636 0 16 20/7 0 908 27AH 5 5 2 5 26 3 664 12 8 325 5527 3 -27 106HT Scoter/ACSS/TW 636 0 23 18/7 0 953 27AH 5 5 2 5 26 3 664 12 8 325 5527 3 -27 106HT Oswego/ACSS/TW 664 8 16 20/7 0 927 27AH 5 5 2 5 26 3 664 12 3 310 5527 3 -27 106HT Mystic/ACSS/TW 666 6 13 20/7 0 913 27AH 5 5 2 5 26 3 664 12 3 310 5530 3 -30 116HT Wabash/ACSS/TW 762 8 16 20/7 0 990 30AH 6 4 2 9 27 1 686 13 4 340 5530 3 -30 116HT Maumee/ACSS/TW 768 2 13 20/7 0 977 30AH 6 4 2 9 27 1 686 13 4 340 5530 3 -30 116HT Tern/ACSS/TW 795 0 7 17/7 0 960 30AH 6 4 2 9 27 1 686 13 4 340 5530 3 -30 116HT Puffin/ACSS/TW 795 0 10 18/7 0 980 30AH 6 4 2 9 27 1 686 13 4 340 5530 3 -30 116HT Condor/ACSS/TW 795 0 13 20/7 0 993 30AH 6 4 2 9 27 1 686 13 4 340 5530 3 -30 122HT Drake/ACSS/TW 795 0 16 20/7 1 010 30AH 6 4 2 9 27 1 686 13 4 340 5530 3 -30 122HT Canary/ACSS/TW 900 0 13 30/7 1 055 30AH 6 3 2 9 27 1 686 13 4 340 5530 3 -30 122HT Fraser/ACSS/TW 946 7 10 35/7 1 077 30AH 6 3 2 9 27 1 686 13 4 340 5530 3 -30 122HT Phoenix/ACSS/TW 954 0 5 30/7 1 044 30AH 6 3 2 9 27 1 686 13 4 340 5530 3 -30 122HT Rail/ACSS/TW 954 0 7 32/7 1 061 30AH 6 3 2 9 27 1 686 13 4 340 5530 3 -30 125HT Cardinal/ACSS/TW 954 0 13 20/7 1 084 30AH 6 2 2 8 27 1 686 13 4 340 5530 3 -30 122HT Kettle/ACSS/TW 957 2 7 32/7 1 060 30AH 6 3 2 9 27 1 686 13 4 340 5530 3 -30 122HT Suwannee/ACSS/TW 959 6 16 22/7 1 108 30AH 6 3 2 9 27 1 686 13 4 340 5530 3 -30 122HT Columbia/ACSS/TW 966 2 13 21/7 1 092 30AH 6 3 2 9 27 1 686 13 4 340 5534 3 - 34 128HT Snowbird/ACSS/TW 1033 5 5 30/7 1 089 34AH 8 9 4 0 28 1 711 14 1 355 5534 3 -34 128HT Ortolan/ACSS/TW 1033 5 7 32/7 1 102 34AH 8 9 4 0 28 1 711 14 1 355 5534 3 -34 134HT Curlew/ACSS/TW 1033 5 13 22/7 1 128 34AH 8 7 4 0 28 1 711 14 1 355 5534 3 -34 128HT — 1080 0 7 20/7 1 131 34AH 8 9 4 0 28 1 711 14 1 355 5534 3 -34 128HT Avocet/ACSS/TW 1113 0 5 30/7 1 129 34AH 8 9 4 0 28 1 711 14 1 355 5534 3 -34 134HT Bluejay/ACSS/TW 1113 0 7 33/7 1 143 34AH 8 6 3 9 28 1 711 14 1 355 5534 3 -34 134HT Finch/ACSS/TW 1113 0 13 38/19 1 185 34AH 8 7 4 0 28 1 711 14 1 355 5534 3 -34 134HT Genesee/ACSS/TW 1158 0 7 33/7 1 165 34AH 8 7 4 0 28 1 711 14 1 355 5534 3 -34 138HT Hudson/ACSS/TW 1158 4 13 26/7 1 196 34AH 8 6 3 9 28 1 711 14 1 355 5534 3 -34 134HT Cheyenne/ACSS/TW 1168 1 5 30/7 1 155 34AH 8 7 4 0 28 1 711 14 1 355 5534 3 -34 138HT Oxbird/ACSS/TW 1192 5 5 30/7 1 167 34AH 8 6 3 9 28 1 711 14 1 355 5534 3 -34 138HT Bunting/ACSS/TW 1192 5 7 33/7 1 181 34AH 8 6 3 9 28 1 711 14 1 355 5536 3 -36 144HT Grackle/ACSS/TW 1192 5 13 38/19 1 225 36AH 9 4 4 3 29 0 733 14 6 370 5534 3 -34 138HT Yukon/ACSS/TW 1233 6 13 38/19 1 245 34AH 8 6 3 9 28 1 711 14 1 355 5534 3 -34 138HT Nelson/ACSS/TW 1257 1 7 35/7 1 213 34AH 8 6 3 9 28 1 711 14 1 355
www.AFLglobal.com or 800-866-7385 HiTemp ® © 2003, AFL, all rights reserved. PP-3-00748, Revision 3, 9.13.16 Specifications are subject to change without notice. 330 ACSS/TW ACCESSORIES HiTemp Tee Connector—Open Run for ACSS/TW Conductor, 5500HT Series (cont.) PARTIAL CATALOG NUMBER CONDUCTOR DIE SIZE WEIGHT RUN LENGTH A BRANCH LENGTH B CODE NAME SIZE TYPE STRANDING DIAMETER RUN BRANCH KCMIL AL/ST IN LBS KG IN MM IN MM 5536 3 -36 144HT Scissortail/ACSS/TW 1272 0 5 30/7 1 202 36AH 9 4 4 3 29 0 733 14 6 370 5534 3 -34 138HT Catawba/ACSS/TW 1272 0 5 30/7 1 203 34AH 8 6 3 9 28 1 711 14 1 355 5536 3 -36 144HT Bittern/ACSS/TW 1272 0 7 35/7 1 220 36AH 9 4 4 3 29 0 733 14 6 370 5536 3 -36 147HT Pheasant/ACSS/TW 1272 0 13 39/19 1 264 36AH 9 3 4 2 29 0 733 14 6 370 5536 3 -36 144HT Thames/ACSS/TW 1334 6 13 39/19 1 290 36AH 9 4 4 3 29 0 733 14 6 370 5536 3 -36 147HT Dipper/ACSS/TW 1351 5 7 35/7 1 256 36AH 9 3 4 2 29 0 733 14 6 370 5538 3 -38 150HT Martin/ACSS/TW 1351 5 13 39/19 1 300 38AH 11 1 5 1 29 9 756 15 2 384 5536 3 -36 144HT Mackenzie/ACSS/TW 1359 7 7 36/7 1 259 36AH 9 4 4 3 29 0 733 14 6 370 5534 3 -34 138HT Truckee/ACSS/TW 1372 5 5 30/7 1 248 34AH 8 6 3 9 28 1 711 14 1 355 5538 3 -38 150HT Bobolink/ACSS/TW 1431 0 7 36/7 1 291 38AH 11 1 5 1 29 9 756 15 2 384 5538 3 -38 156HT Plover/ACSS/TW 1431 0 13 37/19 1 337 38AH 10 8 4 9 29 9 756 15 2 384 5538 3 -38 156HT Merrimack/ACSS/TW 1433 6 13 39/19 1 340 38AH 10 8 4 9 29 9 756 15 2 384 5538 3 -38 156HT Miramichi/ACSS/TW 1455 3 7 36/7 1 302 38AH 10 8 4 9 29 9 756 15 2 384 5538 3 -38 156HT St Croix/ACSS/TW 1467 8 5 33/7 1 292 38AH 10 8 4 9 29 9 756 15 2 384 5538 3 -38 156HT Rio Grande/ACSS/TW 1533 3 13 39/19 1 382 38AH 10 8 4 9 29 9 756 15 2 384 5538 3 -38 156HT Potomac/ACSS/TW 1557 4 7 36/7 1 345 38AH 10 8 4 9 29 9 756 15 2 384 5538 3 -38 156HT Platte/ACSS/TW 1569 0 5 33/7 1 334 38AH 10 8 4 9 29 9 756 15 2 384 5540 3 -40 162HT Lapwing/ACSS/TW 1590 0 7 36/7 1 358 40AH 12 6 5 7 30 8 778 15 8 398 5540 3 -40 162HT Falcon/ACSS/TW 1590 0 13 42/19 1 408 40AH 12 6 5 7 30 8 778 15 8 398 5540 3 -40 162HT Pecos/ACSS/TW 1622 0 13 39/19 1 424 40AH 12 6 5 7 30 8 778 15 8 398 5540 3 -40 162HT Schuylkill/ACSS/TW 1657 4 7 36/7 1 386 40AH 12 6 5 7 30 8 778 15 8 398 5542 3 -40 168HT James/ACSS/TW 1730 6 13 34/19 1 470 42AH 14 6 6 6 31 6 800 16 4 414 5540 3 -40 168HT Pee Dee/ACSS/TW 1758 6 7 37/7 1 427 40AH 13 3 6 1 30 8 778 15 8 398 5540 3 -40 162HT Schuylkill/ACSS/TW 1657 4 7 36/7 1 386 40AH 12 6 5 7 30 8 778 15 8 398 5542 3 -42 168HT James/ACSS/TW 1730 6 13 34/19 1 470 42AH 14 6 6 6 31 6 800 16 4 414 5540 3 -40 162HT Pee Dee/ACSS/TW 1758 6 7 37/7 1 427 40AH 13 3 6 1 30 8 778 15 8 398 5542 3 -42 178HT Chukar/ACSS/TW 1780 0 8 37/19 1 445 42AH 14 2 6 5 31 6 803 16 4 416 5542 3 -42 178HT Cumberland/ACSS/TW 1926 9 13 42/19 1 545 42AH 14 2 6 5 31 6 803 16 4 416 5542 3 -42 178HT Athabaska/ACSS/TW 1949 6 7 42/7 1 504 42AH 14 2 6 5 31 6 803 16 4 416 5544 3 -44 184HT Powder/ACSS/TW 2153 8 8 64/19 1 602 44AH 15 9 7 2 32 5 826 16 0 406 5544 3 -44 184HT Bluebird/ACSS/TW 2156 0 8 64/19 1 608 44AH 15 9 7 2 32 5 826 16 0 406 5548 3 -48 191HT Santee/ACSS/TW 2627 3 8 64/19 1 762 48AH 20 9 9 5 32 5 826 16 0 406
Caractéristiques :
- Aluminium spécialement trempé
- Matrices standard AH et SH
Les applications:
- Connecteur en T à compression pour les conducteurs ACSS/TW
Le connecteur en té de la série 5500HT est une chute permanente spécialement conçue pour les conducteurs ACSS/TW. Il est fabriqué à partir d'un aluminium spécialement trempé qui transfère un courant élevé et dissipe plus efficacement la chaleur accrue.
La partie courante comprend une conception améliorée d'extrusions s'emboîtant les unes dans les autres, offrant une prise permanente sur le conducteur lorsqu'il est comprimé.
La partie en dérivation du connecteur en T est conçue pour une utilisation en tension limitée, en maintenant un minimum de 40 % de la résistance nominale ASTM du conducteur.
Pour les matrices de 30AH et plus, les cônes d'extrémité des parties de compression de tous les accessoires de compression sont fournis avec une finition haute tension.

Grips de traction et HiTemp pour conducteurs ACSR, AAC, AAAC, ACAR, ACSS et ACSS/TW | AFL,Composé de remplissage AFL pour conducteurs électriques | AFL,Composé pour joints électriques Alnox – Accessoires pour conducteurs | AFL,Composé pour joints électriques Alnox UG | AFL,Composé de remplissage HiTemp AFL (AFCHT) | AFL,Composé universel HiTemp AFL (HiTUC) | AFL,Composé pour joints électriques No. 2 | AFL,Manchons d'ancrage à compression HiTemp pour conducteurs ACSS | AFL,Manchons d'ancrage à compression HiTemp pour conducteurs ACSS/TW | AFL,Manchons de jonction à compression HiTemp pour conducteurs ACSS | AFL,Manchons de jonction à compression HiTemp pour conducteurs ACSS/TW | AFL,Raccord de dérivation à compression HiTemp pour conducteurs ACSS | AFL,Raccord de dérivation à compression HiTemp pour conducteurs ACSS/TW | AFL,Manchon de réparation à compression HiTemp pour conducteurs ACSS | AFL,Manchon de réparation à compression HiTemp pour conducteurs ACSS/TW | AFL
688