Australia: 1300 232 476 New Zealand: 09 927 7140 www.AFLglobal.com Test and Inspection 1 © 2002-2020, AFL, all rights reserved. 1576, Revision 2, 17.12.20 Specifications are subject to change without notice. OLS Series Light Sources AFL is a trusted supplier of optical testing equipment with more than 30 years of experience and tens of thousands of units in use in the field. AFL’s full range of light sources are used for testing single-mode and/or multimode fibre networks. Sources with wave ID can transmit two or more wavelengths simultaneously – decreasing test time and reducing user errors when paired with AFL wave ID power meters. Designed for the real world: AFL’s light sources were designed to meet the demands of the outside plant environment. They withstand the one-meter drop and have splash resistant controls that are easy to use, even with gloves on. Flexible and efficient: A range of field-swappable output adapters enables access for cleaning optical ports and supports multiple connector styles. The efficient design provides long test time from globally available AA batteries. External power adapter available for extended testing or lab situations. Reduce test time and errors: Wave ID (Triple, Dual, or Single) decreases test time while reducing technician errors and CW mode provides continuous output (no encoding). Supported output modes: Test Tone (2000, 1000, 330, 270 Hz) for use in fibre identification with AFL brand power meters, OTDRs (with fibre end access) or Optical Fibre Identifier (OFI) products for non-intrusive, mid-span testing. Features • Rugged, dependable, and backed by industry-best 5-year Warranty • Generates up to three Wave ID wavelengths simultaneously - slashing test time • Field-swappable connector adapters for maximum flexibility • Long battery life from globally available AA batteries Applications • Certify multimode and single-mode links per TIA/EIA standards • Link loss measurements • Pair with power meters, OTDRs or OFIs for testing • Fibre identification for splicing and continuity checking OLS7 Optical Laser Source
Australia: 1300 232 476 New Zealand: 09 927 7140 www.AFLglobal.com Test and Inspection 2 © 2002-2020, AFL, all rights reserved. 1576, Revision 2, 17.12.20 Specifications are subject to change without notice. GENERAL SPECIFICATIONS: ALL OLS MODELS Available Adapters SC FC, ST, LC Power 2 AA batteries, optional AC adapter Battery Life SM port: 72 hours typical (40 hours minimum). MM port: 30 hours typical (20 hours minimum) Operating Temperature -10 °C to 50 °C, 90 % RH (non-condensing) Storage Temperature -30 °C to 60 °C, 90 % RH (non-condensing) Size (H x W x D) 14.0 x 8.1 x 3.8 cm (5.5 x 3.2 x 1.5 in) Weight 0.29 kg (0.65 lb) Notes: a. All specifications valid at 25°C unless otherwise specified. b. May be used to test 50 or 62.5 μm fibre with supplied mandrels. c. Output power will be approximately 3 dB less if a 50 μm mandrel-wrapped jumper is used instead of a 62.5 μm mandrel-wrapped jumper. d. Adjustable 2 dB. e. All OLS products come with the UPC optical port. OLS Series Light Sources OLS Series Models and Applications MODEL MM / SM WAVELENGTHS ( nm ) APPLICATIONS OLS1-Dual MM 850, 1300 Ethernet, Token Ring, and FDDI Fibre Links OLS2-Dual SM 1310, 1550 SM Networks, LAN/WAN Testing OLS4 MM / SM 850, 1300 / 1310, 1550 Loss Testing of SM/MM networks OLS7-FTTH SM 1310, 1490, 1550 FTTH Networks OLS7-3 SM 1310, 1550, 1625 Telecom & CATV Networks Specifications a,e OPTICAL SPECIFICATIONS: OLS4, OLS2-DUAL & OLS1-DUAL MODELS MODEL OLS1-DUAL (SINGLE PORT b ) OLS2-DUAL (SINGLE PORT) OLS4 (SM OPTICAL PORT) OLS4 (MM OPTICAL PORT) Wavelength 850 ±30 nm 1300 +30/-20 nm 1310 ±20 nm 1550 ±20 nm 1310 ±20 nm 1550 ±20 nm 850 ±30 nm 1300 +30/-20 nm Spectral Width 45 nm (typ) 120 nm (typ) 5 nm (max) 5 nm (max) 45 nm (typ) 120 nm (typ) Emitter Type LED Laser Laser LED Safety Class Class I FDA 21 CFR 1040.10 and 1040.11, IEC 60825-1: 2007-03 Output Power >-20 dBm, 62.5 μm multimode c 0 dBm, 9 μm single-mode 0 dBm, 9 μm single-mode >-20 dBm, 62.5 μm multimode c Output Stability ±0.1 dB over 8 hours (after 5 minutes warm-up) ±0.05 dB over 1 hour (after 15 minutes warm-up) ±0.1 dB over 8 hours (after 15 minutes warm-up) ±0.1 dB over 8 hours (after 5 minutes warm-up) Tone Output N/A 270 Hz, 330 Hz, 1 kHz, 2 kHz 2 kHz N/A OPTICAL SPECIFICATIONS: OLS7 MODELS MODEL OLS7-FTTH (SINGLE PORT) OLS7-3 (SINGLE PORT) Wavelength (±20 nm) 1310 nm 1490 nm 1550 nm 1310 nm 1550 nm 1625 nm Spectral Width 5 nm 3 nm 5 nm 5 nm 5 nm 2 nm Emitter Type Laser Safety Class Class I FDA 21 CFR 1040.10 and 1040.11, IEC 60825-1: 2007-03 Output Power -5 dBm (typical), 9/125 fibre Output Stability ±0.05 dB over 1 hour (after 15 minutes warm-up) ±0.1 dB over 8 hours (after 15 minutes warm-up) Tone Output 270 Hz, 330 Hz, 1 kHz, 2 kHz
Australia: 1300 232 476 New Zealand: 09 927 7140 www.AFLglobal.com Test and Inspection 3 © 2002-2020, AFL, all rights reserved. 1576, Revision 2, 17.12.20 Specifications are subject to change without notice. OLS Series Light Sources Ordering Information When ordering, specify connector type at the end of model number (e.g. OLS2-DUAL-SC). All OLS models include protective rubber boot, 2 AA batteries, carry case. AC adapters are available (ordered separately), see table below. Test jumpers and connector adapters are required for operation (purchased separately). Test jumpers with a variety of connector styles and fibre types and adapter caps for most common connectors may be purchased from AFL. AFL NO. OUTPUT WAVELENGTHS ( nm ) OUTPUT PORTS EMITTER TYPE WAVE ID TRANSMIT AVAILABLE CONNECTORS POWER 850 1300 1310 1490 1550 1625 OLS1-DUAL 1 LED FC, SC, ST, LC (2) AA, AC OLS2-DUAL 1 Laser FC, SC, ST, LC (2) AA, AC OLS4 2 LED and Laser FC, SC, ST, LC (2) AA, AC OLS7-FTTH 1 Laser FC, SC, ST, LC (2) AA, AC OLS7-3 1 Laser FC, SC, ST, LC (2) AA, AC OLS AC Adapter and Connector Adapters PART NUMBER DESCRIPTION 2900-50-0002MR FC connector adapter 2900-50-0003MR SC connector adapter 2900-50-0004MR ST connector adapter 2900-50-0006MR LC connector adapter 8800-00-0072PR Universal flip-top dust cap for UCI outputs 4050-00-0119PR 100-240 VAC to 9 VDC, AC adapter
Australia: 1300 232 476 New Zealand: 09 927 7140 www.AFLglobal.com Test and Inspection 4 © 2002-2020, AFL, all rights reserved. 1576, Revision 2, 17.12.20 Specifications are subject to change without notice. OLS Series Light Sources Recommended Products Qualifications CATEGORY REGULATION/STANDARD QUALIFICATION CE Marking EU Compliant to relevant EU Directives on health, safety, and environmental protection, and certified with CE marking Safety/EMC/EMI IEC Compliant to IEC 61010-1 for safety requirements for electrical equipment EN Compliant to EN 61010-1 for safety requirements for electrical equipment IEC Compliant to IEC 61326-1 for EMC requirements for electrical equipment EN Compliant to EN 61326-1 for EMC requirements for electrical equipment EN Compliant to EN 55011 for EMC requirements for industrial, scientific and medical equipment FDA Compliant to code of federal regulations FDA 21 CFR 1040.10 and 1040.11 on laser products IEC Compliant to IEC 60825-1 for safety of laser products RoHS EU Compliant to EU regulations Directive 2011/65/EU (RoHS 2) and Directive 2015/863 (RoHS 3) Test Method TIA Compliant to TIA-568.3-D for test and measurement requirements for premises optical fibre cabling and components* IEC Compliant to IEC 11801 for test and measurement requirements for optical fibre cabling for use within premises* EN Compliant to EN 50173 for test and measurement requirements for optical fibre cabling for use within premises* AS/NZS Compliant to AS/NZS 3080 for test and measurement requirements for optical fibre cabling for use within premises* TIA Compliant to TIA-526-7 for test procedures for installed optical fibre cable plant TIA Compliant to TIA-526-14 for test procedures for installed optical fibre cable plant* IEC Compliant to IEC 14763-3 for systems and methods for the inspection and testing of installed optical fibre cabling* AS/NZS Compliant to AS/NZS 14763.3 for systems and methods for the inspection and testing of installed optical fibre cabling* IEC Compliant to IEC 61280-4-1 for test procedures for installed optical fibre cable plant* IEC Compliant to IEC 61280-4-2 for test procedures for installed optical fibre cable plant * A complementary encircled flux mode conditioner may be needed to comply with encircled flux launch conditions for testing multimode optical fibre cabling and components Contact AUSSales@AFLglobal.com to schedule a demonstration or learn how to buy. Visit www.AFLglobal.com/Test to learn more about OLTS kits. International Sales and Service Contact Information available at www.AFLglobal.com/Test/Contacts • World class signal sensitivity • Trigger lock, positive stop for optimum detection • Integrated optical power meter option • Patented single-action • Variety of sizes and types • Low cost per clean Fujikura Optical Fibre Identifier One-Click ® Cleaners
Features:
- 5-Year Product Warranty
- 3-Year Recommended Calibration Interval
- 850 and 1300 nm LED (multimode) light source
- Gigabit Ethernet (GBE) ready
Applications:
- Certify 50 or 62.5 µm fibre links to TIA/EIA Standards
- Certify Multimode fibre links for Gigabit Ethernet (GBE)
- Test Ethernet, Token Ring, and FDDI fibre networks
- 1300 nm port to test up to 10 km single-mode fibre links
Cost effective – LED Source
NOYES OLS1 from AFL is two port multimode LED source for testing multimode fibre links. Packaged in a rugged hand-held case The OLS1 is designed for technicians on the go. The LED output is stabilised to ensure accurate test results per current TIA/EIA requirements.
Low Training Requirements: The OLS1 is easy to operate with only a [Wavelength/ Power] switch, which selects optical wavelengths or disables unit.
LED indicators [Active Output], [Battery], and [External Power] identify the currently enabled output port, battery level, and external power presence.
Weighing only 0.65 lb, the OLS1 is compact and convenient for field use. The OLS1 from AFL operates over 60 hours from a typical 9V alkaline battery. An AC adapter is optional for extended use.
50 and 62.5 µm fibre mandrels Included
Mandrels condition test cable for use in certifying both 50 and 62.5 µm fibre links for current and planned high bit rate applications including Gigabit Ethernet and 10 Gigabit Ethernet. Mandrels apply to launch jumpers is seconds without tools and ensure loss measurements comply with TIA/EIA-568-B standard.
The OLS 1 light source is fully N.I.S.T. traceable.
Key Specifications
OLS1-2C
- Wavelengths: 850 and 1300 nm
- Output Power: -20 dBm into 62.5 µm multimode
- Output Connectors: ST
- Battery: 9V Alkaline
Ordering Information
OLS1 Models
|
Model
|
Description
|
|
OLS1-2C
|
Operates at 850 and 1300 nm for use on Ethernet, Token Ring, and FDDI. The 1300 nm output can also be used to test short distance (up to 10 km) single-mode fibre links.
|
AC Adapter
|
Model
|
Description
|
|
4050-00-0111
|
90-264 VAC to 9 VDC
|

Encircled Flux EF Compliant Test Kits,ROGUE OLTS Certifier,Encircled Flux EF Compliant Light Sources,OLS Series Light Sources,OLS1 Dual LED Light Source with Wave ID,OLS2 Dual Laser Source with Wave ID,OLS7 Triple Wavelength Laser Sources,Test Port Adapters,OPM5 Optical Power Meter with Data Storage,Contractor Series Light Sources and Power Meters,FlowScout™ PON Optical Power Meter,OPM4 Optical Power Meter with Wave ID and Set Reference,OPM5 and OPM4 Optical Power Meters
2472