AFL Duct Cables and Flame Retardant Duct Cables are designed with cable strength suitable for pulling into ducts and sub ducts. These designs are also lightweight with a low friction jacket suitable for blowing installations.
c771d8bd757f4ddf9d5c2f2cc7963954
www.AFLglobal.com 28 FEATURES AFL Duct Cables and Flame Retardant Duct Cables are designed with cable strength suitable for pulling into ducts and sub ducts. These designs are also lightweight with a low friction jacket suitable for blowing installations. DUCT CABLES • Fibre counts up to 288 • Fibre management of 6 to 12 tubes • Dry water-blocking • Metal-free therefore not subject to EMI or earth-bonding requirements • Low friction outer sheath for easy handling and installation • Lightweight and robust construction • Suitable for blowing or pulling installations • All Duct cables are tested to the Construction Products Regulation DESIGN FIBRE COUNT CROSS SECTION OD ( mm ) kg/km STRENGTH ( k N) TEMP RANGE (°C) DU-72CA6/Bk 2-72 10.5 88 2.0 -25 - 65 DU-96CA8/Bk 74-96 12 113 2.0 -25 - 65 DU-144CA12/Bk 98-144 14 139 2.0 -25 - 65 DU-288CA12/Bk 146-288 17 222 2.0 -25 - 65 DUCT CABLE CPR rated to class F CA
www.AFLglobal.com 29 DESIGN FIBRE COUNT CROSS SECTION OD ( mm ) kg/km STRENGTH ( k N) TEMP RANGE (°C) DU-72LSA6/Bk 2-72 10.5 118 2.0 -25 - 65 DU-96LSA8/Bk 74-96 12.5 157 2.0 -25 - 65 DU-144LSA12/Bk 98-144 14 176 2.0 -25 - 65 DESIGN FIBRE COUNT CROSS SECTION OD ( mm ) kg/km STRENGTH ( k N) TEMP RANGE (°C) DU-72LSG6/Bk 2-72 10.5 117 2.7 -25 - 65 DU-96LSG8/Bk 74-96 12.5 156 2.7 -25 - 65 DU-144LSG12/Bk 98-144 14 188 2.7 -25 - 65 DESIGN FIBRE COUNT CROSS SECTION OD ( mm ) kg/km STRENGTH (k N) TEMP RANGE (°C) DU-72CG6/Bk 2-72 10.5 91 2.7 -25 - 65 DU-96CG8/Bk 74-96 12 123 2.7 -25 - 65 DU-144CG12/Bk 98-144 14 170 2.7 -25 - 65 CPR rated to class F CA CPR rated to class E CA CPR rated to class E CA LSZH DUCT CABLE GLASS REINFORCED LSZH DUCT CABLE DUCT CABLES GLASS REINFORCED DUCT CABLE Single-mode, multi-mode and non-zero dispersion-shifted fibre types are available on request
Features
- Fibre counts up to 288
- Fibre management of 6 to 12 tubes
- Dry water-blocking
- Metal-free therefore not subject to EMI or earth-bonding requirements
- Low friction outer sheath for easy handling and installation
- Lightweight and robust construction
- Suitable for blowing or pulling installations
- All Duct cables are tested to the Construction Products Regulation
Applications
- Distribution
- Underground Duct
- Long Haul Networking
- Building Interconnections (Campus LAN)
- Trunking Lines Direct to Telecommunications Closet
- Local Loop
AFL Duct Cables and Flame Retardant Duct Cables are designed with cable strength suitable for pulling into ducts and sub ducts. These designs are also lightweight with a low friction jacket suitable for blowing installations.
Furcation Tubing,Simplex Cable,Zipcord DualLink and MicroDual Cable,Duct Cable,GelFree Riser NonArmored Loose Tube LV Series GelFree SJ,IndoorOutdoor Armored Tight Buffered Circular Premise Cable,IndoorOutdoor Breakout Cable,IndoorOutdoor Multi unit Plenum Tight Buffered Cable,IndoorOutdoor Multi unit Riser Tight Buffered Cable,IndoorOutdoor Plenum Distribution Cable,IndoorOutdoor Riser Sub unitized MicroCore Cable,IndoorOutdoor Riser Sub unitized MicroCore Cable with SpiderWeb Ribbon Technology,IndoorOutdoor Riser Tight Buffered Cable,Low Smoke Zero Halogen IndoorOutdoor Breakout Cable