FAQ: FASTConnect® Specific

Referencing our FASTConnect® field installable connectors.

 

Q: What are the differences between the CT-50 and the CT-16 cleavers included in the FASTConnect tool kits?
A: The CT-50 fiber cleaver has an automated 16-position blade that yields up to 60,000 single-fiber cleaves, or 5,000 12-fiber ribbon cleaves before requiring replacement. The CT-50 cleaver is Bluetooth enabled for connection to Fujikura splicing machines, allowing for automated blade rotation based on the count or quality of cleaves. The CT-16 cleaver is designed for single or dual-fiber cleaving only, and the adjustable blade yields up to 48,000 cleaves.

Q: Why am I getting high loss when terminating FASTConnect Mechanical Connectors?
A: High loss is typically yielded while terminating FASTConnect due to poor fiber insertion. If the fiber was broken inside the connector, a new connector is needed. If a fiber was not broken inside the connector, the FASTConnect can be re-terminated up to 5 different times*. Place the wedge clip back onto the connector with the "1" on the wedge clip facing the ferrule and push until a clip is heard to reengage the wedge. You may then re-terminate your fiber.
A good cleave is the most important factor in getting a good termination. Re-cleave before re-inserting the fiber into the connector. If the above does not provide a solution, rotate the cleaver blade. Reinsert the fiber, making sure to create a slight bend in the fiber before releasing the wedge clip.
If issues persist with high loss after trying to re-insert the fiber five times, contact AFL technical support.
*The FASTConnect ST Connector may be reused prior to application of the housing to the connector body. After the connector housing has been applied the design is no longer reusable.

Q: Why am I unable to insert the fiber into the connector?
A: Sometimes the wedge clip comes disengaged during transportation. If so, the installer will be unable to insert the fiber into the connector. To properly engage, squeeze the top and bottom of the wedge clip. If it disengages, you will hear a click.
If the fiber is cleaved too long (greater than 10.5mm) the clamping mechanism of the mechanical connector will not clamp to the appropriate parts of the fiber, resulting in an improper insert. In this case, installers should strip, clean, cleave and reinsert the fiber.

Q: Why is the VFL not working?
A: The VFL may not be working for several reasons. If the fiber was inserted incorrectly this would be cause for the light to not dim properly. If a fiber is broken inside the connector, the connector itself will be unusable and the VFL will not work.
Always remember that the VFL capability of the FASTConnect connectors is to be used as a verification tool, not a validation tool. The tool is useful as a secondary confirmation after creating a slight bend in the fiber, but should not be the only step used to confirm that proper termination has occurred.
If problems persist when terminating FASTConnect connectors while using a VFL it does not signify a bad connector without proper loss test results to prove a bad connection has been made.

Q: What is the index of refraction over temperature?
A: The refractive index is 1.469 at 25°C with a thermo-optic coefficient of less than 4.0 x 10-4/°C.

Q: How do you prevent the gel from drying out inside of the connector?
A: The gel has a low evaporation rate. Index matching gel within FASTConnect connectors has a shelf life of 20 years.

Q: What prevents the gel from migrating away from the fiber?
A: The upper body of the mechanical splice mechanism is designed such that the surface area clamping onto bare fiber is minimized, and prevents the gel from migrating away from the splice point.

Q: Can I use ___ cleaver when prepping my fiber to terminate a FASTConnect?
A: AFL always recommends the use of a precision cleaver to cleave fiber for termination preparation into a FASTConnect connector. AFL offers the CT-50 and CT-16 cleavers for field cleaving and termination. Our recommended cleave length is 10.5mm. Other vendors may be used, but it is critical that they are able to cleave the fiber to 10-11mm or the cleave length will not be correct for proper termination in the connector.