Internal damper is designed to be welded inside bus, to be corona free and to present a "clean" appearance to the substation. External damper is to be bolted to outside of tube.
d9129f85ff21470796d9cab7fa2ee741
480 345/500 kV Vibration Dampers © 2011, AFL, all rights reserved. PP-3-00163, Revision 3, 8.12.15 Specifications are subject to change without notice. 345/500 kV Vibration Dampers www.AFLglobal.com or 800-890-8878 TYPE 1705-EHV, 1706-EHV Internal and External Vibration Damper Internal and external damper is designed to be corona free (see chart below for voltage ratings). Internal damper is designed to be welded inside bus, to be corona free, and to present a "clean" appearance to the substation. External damper is to be bolted to outside of tube. External damper can be installed during construction or at a later time to correct vibration problems not originally anticipated. 1705-EHV Material Aluminum Alloy 1706-EHV 1705 B A A 1706-EHV CUSTOMER PIPE Ordering Information INTERNAL DAMPER CATALOG NUMBER CONDUCTOR SIZE DIMENSIONS IN INCHES NOMINAL WEIGHT IN LBS A ALUMINUM TOTAL 1705-504 5 SPS 36.88 2.7 13.3 1705-576 6 EHPS 35.25 3.3 14.0 1705-607 6 SPS 35.25 4.0 14.7 1705-762 8 EHPS 36.88 3.3 13.9 1705-798 8 SPS 36.88 3.4 14.0 1705-700 8" OD x 1/2 WALL 36.88 3.2 13.8 1705-725 8" OD x 3/8 WALL 36.88 3.2 13.8 EXTERNAL DAMPER CATALOG NUMBER VOLTAGE RATING CONDUCTOR SIZE SPS & EHPS DIMENSIONS IN INCHES NOMINAL WEIGHT IN LBS A B ALUMINUM TOTAL 1706-008 EHV 345 kV 3 28.0 12.6 1.9 15.6 1706-009 EHV 345 kV 3 1/2 27.8 13.2 2.0 15.7 1706-010 EHV 345 kV 4 27.6 13.6 2.1 15.8 1706-012 EHV 345 kV 5 26.8 15.4 2.5 16.2 1706-013 EHV 345 kV 6 26.2 17.8 2.7 16.4 1706-014 EHV 500 kV 8" OD 24.8 18.6 3.9 17.6 Hardware Aluminum nuts, bolts, and lockwashers.
Features:
- Aluminum alloy
- Anodized aluminum hardware
- Vibration dampers
Applications:
- Rated for 345/500 kV and below
- Substation
- Aluminum bus pipe
Internal and external damper is designed to be corona free (see sales sheet for
voltage ratings). Internal damper is designed to be welded inside bus, to be corona
free and to present a "clean" appearance to the substation. External damper is to be
bolted to outside of tube. External damper can be installed during construction or at
a later time to correct vibration problems not originally anticipated.

230 kV Aluminum Compression Couplers,230 kV Aluminum Compression Tee Connectors,230 kV Aluminum Compression Tee Terminal Connectors,230 kV Aluminum Compression Terminal Connectors,230 kV Aluminum Welded Bus Pipe Couplers,230 kV Aluminum Welded Bus Pipe Elbows,230 kV Aluminum Welded Bus Pipe Supports,230 kV Aluminum Welded Bus Pipe Tee and Vee Connectors,230 kV Aluminum Welded Bus Pipe Terminal Connectors,230 kV Aluminum Welded Bus Pipe to Cable Couplers,230 kV Aluminum Welded Bus Pipe to Cable Tee,230 kV Aluminum Welded Cable Terminal,230 kV Aluminum Welded End Plugs,230 kV Aluminum Welded Grounding Rod,230 kV Aluminum Welded Pipe Taps
465