Bolted ground stud is designed to be corona free for 345 kV and 500 kV service.
d9129f85ff21470796d9cab7fa2ee741
547 © 2011, AFL, all rights reserved. PP-3-00182, Revision 1, 9.20.18 Specications are subject to change without notice. 345/500 kV Ground Jumpers 345/500 kV Ground Jumpers www.AFLglobal.com or 800-890-8878 TYPE 34600-EHV Bolted ground stud is designed to be corona free for 345 kV and 500 kV service as noted in table. Bolted design provides ease of removal for future expansion or relocation. Ordering Information CATALOG NUMBER SPS / EHPS DIMENSIONS IN INCHES NOMINAL WEIGHT LBS A B 345 KV 34668 EHV 3 16.31 7.06 5.2 34669 EHV 3 1/2 16.56 7.06 5.3 34670 EHV 4 16.81 7.06 5.5 34672 EHV 5 17.34 7.06 5.8 34673 EHV 6 17.87 7.06 6.4 500 KV 34688 EHV 3 21.25 12 13.3 34689 EHV 3 1/2 21.50 12 13.4 34690 EHV 4 21.75 12 13.6 34692 EHV 5 22.28 12 13.9 34693 EHV 6 22.81 12 14.5 B ∅ .88 6 A Material Aluminum Alloy Hardware Yellow anodized aluminum bolts, nuts, and lockwashers. Notes • For Stainless Steel bolts, lockwashers and Everdur nuts, add "-SSHBN" to catalog number. EX: 34668EHV-SSHBN
345/500 kV Ground Jumpers 549 © 2011, AFL, all rights reserved. PP-3-00183, Revision 12, 12.4.13 Specications are subject to change without notice. 345/500 kV Ground Jumpers www.AFLglobal.com or 800-890-8878 TYPE 34620-EHV Ordering Information CATALOG NUMBER DIMENSIONS IN INCHES VOLTAGE RATING NOMINAL WEIGHT LBS A B 34620EHV 21.50 7.06 345 kV 4.7 34625EHV 26.19 12.00 500 kV 13.6 Ground stud is designed to be corona free for 345 kV or 500 kV service, as noted in table, when pad covers are used to shield terminal hardware. 4.5 1.125 4 1.75 1.75 .69 ∅ 1.315 6 B A
613 765 kV Ground Stud © 2011, AFL, all rights reserved. PP-3-00184, Revision 0, 3.15.11 Specifications are subject to change without notice. 765 kV Ground Stud www.AFLglobal.com or 800-890-8878 34640-EHV TYPE 34640-EHV Series Ground Stud, Welded Ground stud is designed to be corona free for 765 kV operation. Ordering Information CATALOG NUMBER CONDUCTOR SIZE TUBULAR SIZE SPS & EHPS NOMINAL WEIGHT LBS 34640EHV 4" to 6" 16.0 Material Aluminum Alloy 1" SCH 80 ALUM. PIPE 15.00" CUSTOMER PIPE 6.00"
548 © 2011, AFL, all rights reserved. PP-3-00185, Revision 1, 10.31.11 Specications are subject to change without notice. 345/500 kV Ground Jumpers 345/500 kV Ground Jumpers www.AFLglobal.com or 800-890-8878 TYPE 34650-EHV Ordering Information CATALOG NUMBER MAX CONDUCTOR DIAMETER DIMENSIONS IN INCHES NOMINAL WEIGHT LBS A C BOLT SIZE 34653EHV 1.226 15.25 5.00 5/8 7.8 34654EHV 1.475 15.38 5.50 5/8 8.8 34655EHV 1.850 15.75 5.75 3/4 13.3 Bolted conductor ground stud is designed to have better corona characteristics than the conductor on which it is installed. Designed for 500 kV service. Bolted design provides ease of removal for future expansion or relocation. Ground stud is ordered by specifying catalog number and conductor. 7.06 IN C A .840 IN. DIA. Material Aluminum Alloy Hardware Yellow anodized aluminum bolts, nuts, and lockwashers.
546 345/500 kV Ground J umpers © 2011, AFL, all rights reserved. PP-3-00526, Revision 0, 3.4.11 Specifications are subject to change without notice. 345/500 kV Ground Jumpers www.AFLglobal.com or 800-890-8878 Ordering Information CATALOG NUMBER SPS / EHPS DIMENSIONS IN INCHES D E WGPHV250-AA 2 1/2 3/4 8 WGPHV300-AA 3 3/4 8 WGPHV300-12-AA 3 3/4 12 WGPHV350-AA 3.5 3/4 8 WGPHV400-AA 4 3/4 8 WGPHV400-10-AA 4 3/4 10 WGPHV400-12-R87-AA 4 7/8 12 WGPHV500-AA 5 3/4 10 WGPHV500-10-AA 5 3/4 12 WGPHV500-R81-AA 5 13/16 10 WGPHV600-AA 6 3/4 10 WGPHV600-12-AA 6 3/4 12 WGPHV600-R81-AA 6 13/16 10 WGPHV800-AA 8 3/4 13 WGPHV800R-AA 8 O.D. 3/4 13 Welded ground stud is designed to be corona free for 345 kV and 500 kV service. Design of ground studs is such that then can be welded to 3" through 6" SPS pipe size. TYPE WGPHV-AA Ground Jumper Material Aluminum Alloy FIELD WELD 6" D FACTORY WELD E
Features:
- Aluminum alloy
- Welded corona ball
Applications:
- Rated for 500 kV and below
- Substation
Bolted ground stud is designed to be corona free for 345 kV and 500 kV service. Bolted and welded accessories are available for connecting to bus pipe or cable conductors.
230 kV Aluminum Compression Couplers,230 kV Aluminum Compression Tee Connectors,230 kV Aluminum Compression Tee Terminal Connectors,230 kV Aluminum Compression Terminal Connectors,230 kV Aluminum Welded Bus Pipe Couplers,230 kV Aluminum Welded Bus Pipe Elbows,230 kV Aluminum Welded Bus Pipe Supports,230 kV Aluminum Welded Bus Pipe Tee and Vee Connectors,230 kV Aluminum Welded Bus Pipe Terminal Connectors,230 kV Aluminum Welded Bus Pipe to Cable Couplers,230 kV Aluminum Welded Bus Pipe to Cable Tee,230 kV Aluminum Welded Cable Terminal,230 kV Aluminum Welded End Plugs,230 kV Aluminum Welded Grounding Rod,230 kV Aluminum Welded Pipe Taps
804
500 kV Aluminum Ground Jumpers
Close
500 kV Aluminum Ground Jumpers
Features:
- Aluminum alloy
- Welded corona ball
Applications:
- Rated for 500 kV and below
- Substation
PRODUCT DESCRIPTION
Bolted ground stud is designed to be corona free for 345 kV and 500 kV service. Bolted and welded accessories are available for connecting to bus pipe or cable conductors.