      The U-Series 2RU Front-Access V-Panel (FVP) facilitates rapid, cold-aisle, front-access splicing and patching of up to 288 fibers utilizing SpiderWeb Ribbon® (SWR®) Technology to pre-loaded, high-performance SWR LC pigtails.
      bd4e4d6a81464d2283067d724fd6c742
      1 AFLglobal.com 1 (800) 866-7385 © 2021, AFL, all rights reserved. PP-2-00340, Revision 2, 10.31.2025 S p e c i  c a t i o n s a r e s u b j e c t t o c h a n g e w i t h o u t n o t i c e . Optical Connectivity 1 2RU Front-Access V-Panel (FVP) The 2RU Front-Access V-Panel (FVP) facilitates rapid, cold-aisle, front-access splicing and patching of up to 288 fibers utilizing SpiderWeb Ribbon ® (SWR ® ) Technology to pre-loaded, high-performance SWR LC pigtails. The rack-mountable unit is lightweight and sturdy and easy for one person to install. A slide-out modular drawer is dismounted from the panel so splicing can take place on a workbench at a safe working height. Its V-shaped design provides easy finger access and LC quad shuttered adapters help prevent the ingress of dust or debris while additionally providing laser eye safety. Features • State-of-the-art V-shaped design with a slide-out drawer allows for splicing in an ergonomic, modular, sleek interface • Slide-out drawer pre-loaded with 24F 200 μm SpiderWeb Ribbon LC Pigtails • Ample slack in drawer enables splicing on a workbench at a safe working height as well as multiple re-splices • 2RU 19" rack-mount panels are stackable with the possibility of feeding in cable from the left or right side • Integrated mounting points for cable transitions ensure appropriate management of breakout from cable to splicing area • Accommodates 288F within the slide-out drawer, containing 12 x 24F FVP LC Cassettes • LC quad shuttered adapters help prevent the ingress of dust or debris while also providing laser eye safety • 288F or 2 x 144F SWR cable can be mounted from the left or right side • 6RU option available for the splicing and patching of 864 fibers • Pivoting front and back door can be removed during installation Applications • Hyperscale • Colocation • Data Halls • Main Distribution Areas (MDAs) • Fiber Entrance Facilities Ordering Information Description Application AFL No. 2RU Front Access V Panel Splice Patch BK Premium LC G.657A1 288F (250 μm-pitch Pigtail) 250 μm-pitch version work with SR15E-200 fiber cable F7HAADBPAX-10AM FVP Splice Cassette BK Premium LC SM G.657A1 24F Stub OFNP SWR 250 μm-Pitch MC 4M 250 μm-pitch version work with SR15E-200 fiber cable A7UD24BPAX-14JF-M4 2RU Front Access V Panel Splice Patch BK Premium LC G.657A1 288F (200 μm-pitch Pigtail) 200 μm-pitch version work with SR15E-P200 fiber cable F7HAADBPAX-15AM FVP Splice Cassette BK Premium LC SM G.657A1 24F Stub OFNP SWR 200 μm-Pitch MC 4M 200 μm-pitch version work with SR15E-P200 fiber cable A7UD24BPAX-14JW-M4 2 AFLglobal.com 1 (800) 866-7385 © 2021, AFL, all rights reserved. PP-2-00340, Revision 2, 10.31.2025 S p e c i  c a t i o n s a r e s u b j e c t t o c h a n g e w i t h o u t n o t i c e . Optical Connectivity 2 2RU Front-Access V-Panel (FVP) Technical Drawings Specifications Parameter Value Dimensions 482 mm (W) x 88 mm (H) x 559 mm (D) Max Fiber Count (Ribbon Cable) 288 Cable Entry Left or Right Material CR4 Steel, Aluminum Material Thickness 1 mm to 2 mm Material Coating Powder Weight 7.5 kg Color Black Operating Temperature -20°C to +50°C Qualifications Governing Body Standard Code RoHS Compliant Reach Compliant SVHC Compliant 441 mm 480 mm 88 mm (2RU) 159 mm 400 mm 194 mm 41 mm

      FEATURES:

      • State-of-the-art V-shaped design with a slide-out drawer allows for splicing in an ergonomic, modular, sleek interface
      • The slide-out drawer comes pre-loaded with 24f 200μm SpiderWeb Ribbon (SWR) LC Pigtails
      • Ample slack in drawer enables splicing on a workbench at a safe working height as well as multiple re-splices
      • 2RU 19″ rack-mount panels are stackable with the possibility of feeding in cable from the left or right
      • Integrated mounting points for cable transitions ensure appropriate management of breakout from cable to splicing area
      • Accommodates 288f within the slide-out drawer, containing 12 x 24f FVP LC Cassettes
      • LC quad shuttered adapters help prevent the ingress of dust or debris whilst additionally providing laser eye safety
      • 288f or 2 x 144f SWR cable can be mounted from the left or right
      • 6RU option available for the splicing and patching of 864 fibers
      • Pivoting front and back door can be removed during installation

       

      Accessories included with shipped panel:

      • 12 x 24f 200μm SpiderWeb Ribbon (SWR) LC Pigtails (Pre-Installed)
      • 4 x Cable Ties
      • 2 x 144f Ribbon Mass Splice Tray
      • 12 x 24f Ribbon Splice Protectors
      • 2 x M6 Cage Nuts and Screws
      • 5m Nylon Braid
      • 1.5 x Ø10mm OD Fiber Braid Tube (1m)
      • 1 x Electrical Tape
      • 2m Velcro
      • 2 x Hose Clip
      • 4 x M6 10 Screw

      Applications:

      • Hyperscale
      • Colocation
      • Data halls
      • Main Distribution Areas (MDAs)
      • Fiber entrance facilities

      The U-Series 2RU Front-Access V-Panel (FVP) facilitates rapid, cold-aisle, front-access splicing and patching of up to 288 fibers utilizing SpiderWeb Ribbon® (SWR®) Technology to pre-loaded, high-performance SWR LC pigtails.

      The one-person rack-mountable unit is easy to work with and both lightweight and sturdy. A slide-out modular drawer is dismounted from the panel so splicing can take place on a workbench at a safe working height. Its V-shaped design provides easy finger access and LC quad shuttered adapters help prevent the ingress of dust or debris whilst additionally providing laser eye safety.

       

      Specifications

      Element Characteristic
      Dimensions 482mm (W) x 559mm (D) x 88mm (H)
      Maximum fiber count (ribbon cable) 288f
      Cable entry Left or right
      Material CR4 Steel
      Aluminum
      Material thickness 1 mm to 2 mm
      Material coating Powder
      Weight 7.5kgs
      Color Black
      Operating temperature -20°C to +50°C
      Materials compliant to RoHS, Reach / SVHC

      Ordering Information

      Part Number Description
      F7HAADBPAX-10AM U-Series High Capacity 2U Front Access V Patch Panel Black Premium LC G.657A1 288F (SWRPigtails)
      A7UD24BPAX-14JF-M4 U-SeriesFVP24f Pigtail Cassette with PremiumLCSMG.657A1 24F 4m Stub 3.0mm OD

      U-Series-2RU-Front-Access-V-Panel-FVP-1536x1024.jpg
      MTP PRO Field Tool for PolarityPin Change | AFL,AFL 6912 Fiber Breakout Box for High-Core SWR Cables | AFL,U Series 6RU Fiber Splice and Patch Panel | AFL,FVP Pre Terminated Replacement Cassette | AFL,3456 Fiber Breakout Box | AFL,6RU Front-Access V-Panel (FVP) | AFL
        DescriptionResourcesGet a Quote
        Download Specification Sheet
        U-Series-2RU-Front-Access-V-Panel-FVP-1536x1024.jpg
        Media Content
        Close

        U-Series 2RU Front-Access V-Panel (FVP)

        FEATURES:

        • State-of-the-art V-shaped design with a slide-out drawer allows for splicing in an ergonomic, modular, sleek interface
        • The slide-out drawer comes pre-loaded with 24f 200μm SpiderWeb Ribbon (SWR) LC Pigtails
        • Ample slack in drawer enables splicing on a workbench at a safe working height as well as multiple re-splices
        • 2RU 19″ rack-mount panels are stackable with the possibility of feeding in cable from the left or right
        • Integrated mounting points for cable transitions ensure appropriate management of breakout from cable to splicing area
        • Accommodates 288f within the slide-out drawer, containing 12 x 24f FVP LC Cassettes
        • LC quad shuttered adapters help prevent the ingress of dust or debris whilst additionally providing laser eye safety
        • 288f or 2 x 144f SWR cable can be mounted from the left or right
        • 6RU option available for the splicing and patching of 864 fibers
        • Pivoting front and back door can be removed during installation

         

        Accessories included with shipped panel:

        • 12 x 24f 200μm SpiderWeb Ribbon (SWR) LC Pigtails (Pre-Installed)
        • 4 x Cable Ties
        • 2 x 144f Ribbon Mass Splice Tray
        • 12 x 24f Ribbon Splice Protectors
        • 2 x M6 Cage Nuts and Screws
        • 5m Nylon Braid
        • 1.5 x Ø10mm OD Fiber Braid Tube (1m)
        • 1 x Electrical Tape
        • 2m Velcro
        • 2 x Hose Clip
        • 4 x M6 10 Screw

        Applications:

        • Hyperscale
        • Colocation
        • Data halls
        • Main Distribution Areas (MDAs)
        • Fiber entrance facilities
        Download Specification SheetPDFSHARE SPECS✉

        Loading component...

        Documents & Downloads
        Close

        Specification Sheet

        • spec icon
          Download Specification Sheet
          Download Specification Sheet

        Related Products

        HOW CAN WE HELP TODAY?

        Reason for Contact

        footer-logo
        Connect with us:
        LinkedIn Facebook Twitter YoutTube Instagram
        Give us a call:
        Vector Smart Object+1 (800) 235-3423
        PRODUCT DESCRIPTION

        The U-Series 2RU Front-Access V-Panel (FVP) facilitates rapid, cold-aisle, front-access splicing and patching of up to 288 fibers utilizing SpiderWeb Ribbon® (SWR®) Technology to pre-loaded, high-performance SWR LC pigtails.

        The one-person rack-mountable unit is easy to work with and both lightweight and sturdy. A slide-out modular drawer is dismounted from the panel so splicing can take place on a workbench at a safe working height. Its V-shaped design provides easy finger access and LC quad shuttered adapters help prevent the ingress of dust or debris whilst additionally providing laser eye safety.

         

        Specifications

        Element Characteristic
        Dimensions 482mm (W) x 559mm (D) x 88mm (H)
        Maximum fiber count (ribbon cable) 288f
        Cable entry Left or right
        Material CR4 Steel
        Aluminum
        Material thickness 1 mm to 2 mm
        Material coating Powder
        Weight 7.5kgs
        Color Black
        Operating temperature -20°C to +50°C
        Materials compliant to RoHS, Reach / SVHC

        Ordering Information

        Part Number Description
        F7HAADBPAX-10AM U-Series High Capacity 2U Front Access V Patch Panel Black Premium LC G.657A1 288F (SWRPigtails)
        A7UD24BPAX-14JF-M4 U-SeriesFVP24f Pigtail Cassette with PremiumLCSMG.657A1 24F 4m Stub 3.0mm OD