Multi-Fiber network construction is time consuming, complicated, and often built by more than one crew with mixed sets of documentation. Mistakes, such as mislabeling, are almost guaranteed. AFL’s Multi-Fiber Identification System (MFIS) provide 100% multi-fiber network continuity assurance. It is a simple user-friendly way to verify network construction quickly, correctly, and efficiently.
98a1c258fe554a3380bc8e9eda6f31df,b4ab32726df14c83b651d37485046628
1 Test & Inspection AFLglobal.com | 800.235.3423 Fiber Identification MFIS Multi-Fiber Identification System ©2020, AFL, all rights reserved. MFIS-00-2000 Revision AB, 2020-11-19 Specifications are subject to change without notice. Multi-fiber network construction is time consuming, complicated, and often built by more than one contractor with mixed sets of documentation. There are guaranteed to be mislabeled and cross-connected fibers, which cost valuable time to find and fix. AFL’s Multi-Fiber Identification System (MFIS) is a simple user-friendly way to verify network construction quickly and efficiently. Rugged lightweight tools that can be operated with one hand: MFIS is a set of three tools that can be used to easily verify the fiber ID. The MFT (Multi-Fiber Trace) features 12 discrete laser sources (1550 nm single-mode) and an MTP fan-out connector. The digitally-coded light is then detected by either the MFI (Multi-Fiber Identifier), which clamps onto the fiber under test or the MFP (Multi-Fiber Power Meter), which plugs into the fiber under test. Slash multiple fiber activations cost by up to 75% over conventional method: During service activation field technicians often run into unlabeled, mislabeled, and cross-connected fibers that can take two technicians hours to figure out - increasing cost and delaying service for customers. MFIS enables one technician to verify up to 12 fibers at a time, slashing the time it takes to activate new customers. Ensure 100% multi-fiber network continuity: MFIS can be used to efficiently verify potentially cross-connected fibers at any point of an existing network – providing peace of mind to network managers. Features • Identifies up to 12 fibers at a time • Light-weight, rugged, and can be operated with one hand • Optimized for use on 250 μm, 900 μm, and ribbon fiber • Three-year calibration interval Applications • Multi-fiber network continuity assurance • Fiber identification on both MFP power meter and MFI identifier • Verify long-haul networks (up to 110 miles) • Quickly verify FlexNap ® network mapping
2 Test & Inspection AFLglobal.com | 800.235.3423 Fiber Identification MFIS Multi-Fiber Identification System ©2020, AFL, all rights reserved. MFIS-00-2000 Revision AB, 2020-11-19 Specifications are subject to change without notice. Notes: a. All specifications valid at 25 °C unless otherwise specified. b. All specs are typical unless otherwise noted. Actual results can vary by several dB depending on fiber type, coating material, jacket color, jacket hardness, active fiber position, and other factors. c. Operation is defined as turning unit on by taking 1 reading in a 10 second period. MFT Multi-Fiber Tracer Specifications a OPTICAL Wavelength 1550 ±20 nm Spectral Width 5 nm (maximum) Output Power +1.75 dBm ±1 dB peak into 9/125 μm fiber @ +25 °C GENERAL Power Supply 2 X 1.5 V AA alkaline batteries Battery Life (Alkaline) @ +25 °C: 40 hours (minimum); 50 hours (typical) Connectors SM: MTP/MPO-APC (unpinned) 12-fiber connector. Size (without boot) W x L x H 96 x 145 x 35 mm (3.8 x 5.7 x 1.4 in) Weight 307 g (0.676 lb) without boot; 458 g (1.01 1b) with boot Operational Temperature -20 °C to +50 °C 90 % RH (non-condensing) Storage Temperature -30 °C to +60 °C 90 % RH (non-condensing) MFI Multi-Fiber Identifier Specifications a , b FIBER TYPE PARAMETER WAVELENGTH, SIGNAL DETECTABLE SIGNAL RANGE 250 μm ribbon fiber, SMF28e+ Minimum data detect level (peak power, typical) 1550 nm, Data – Fiber ID -35 dBm (typical) Insertion loss (typical/maximum) 1550 nm 2.5 dB/3.0 dB OPTICAL Detector Type InGaAs Calibrated Fiber Size and Wavelength 250 μm @1550 nm (SMF-28/28E) ribbon fiber Working Fiber Size 250 μm ribbon fiber Data Detection Range +2 to -35 dBm GENERAL Display Type Multi 7-segment LCD, 3 LEDs Power Supply 2 X 1.5 V AAA, alkaline batteries Battery Life (backlight off) >10,000 operations c Operation Temperature -20 °C to +50 °C 90 % RH (non-condensing) Storage Temperature -30 °C to +60 °C 90 % RH (non-condensing) Dimensions (H x W x D) 22 x 3.8 x 2.8 cm (8.5 x 1.5 x 1.1 in) Weight 168 g (6 oz)
3 Test & Inspection AFLglobal.com | 800.235.3423 Fiber Identification MFIS Multi-Fiber Identification System ©2020, AFL, all rights reserved. MFIS-00-2000 Revision AB, 2020-11-19 Specifications are subject to change without notice. MFP Multi-Fiber Power Meter Specifications a OPTICAL Detector Type InGaAs Detector Size 1 mm OPM Mode Calibrated Wavelength 850, 1300, 1310, 1490, 1550, 1625 nm Measurement Range +10 to -75 dBm Accuracy b ±0.25 dB Resolution 0.01 dB Measurement Units dB, dBm, μW Fiber ID Mode e Wavelength 1550 nm Measurement Range c +10 to -35 dBm Accuracy d ±0.5 dB Resolution 0.01 dB Measurement Units dB, dBm, μW Notes: a. All specifications valid at 25 °C unless otherwise specified. b. Accuracy measured at 25 ºC and -10 dBm per N.I.S.T. standards. c. Measured using MFT (Multi-Fiber Tracer) as the light source. d. Accuracy measured at 25 ºC with MFT (Multi-tiber Tracer). e. Subject to change. Ordering Information DESCRIPTION AFL NO. Multi-Fiber Identifier, no case MFI1-00-0900MR Multi-Fiber Power Meter, no case MFP1-12-0900MR Multi-Fiber Tracer & Identifier with soft case MFTI-12-BAS Multi-Fiber Tracer & Power Meter with soft case MFTP1-12-BAS Multi-Fiber Tracer, Identifier, and Power Meter with soft case MFTIP1-12-BAS ACCESSORIES Cable, MPO/APC(M)-SC/APC, 12-fiber, SM, fan-out, 3 meters 8700-00-0198MR Cable, MPO/APC (M) - SC/UPC, 12-fiber, SM, fan-out, 3 meters 8700-00-0200MR Cable, MPO/APC (M) - LC/UPC, 12-fiber, SM, fan-out, 3 meters 8700-00-0201MR One-Click Cleaner MPO (500+ cleans) 8500-05-0030MZ One-Click Cleaner Mini-100 SC, ST, FC (100+ cleans) 8500-05-0005MZ GENERAL Power 2 x AA batteries, accepts standard mini-USB power adapter Adapter Caps Order with one: 1.25 mm Universal, 2.5 mm Universal, FC, SC, ST, LC. Other connector adapters available Battery Life 300 hours Operating Temperature -10 °C to 50 °C, 90 % RH (non-condensing) Storage Temperature -30 °C to 60 °C, 90 % RH (non-condensing) Size (H x W x D) 14.0 x 8.1 x 3.8 cm (5.5 x 3.2 x 1.5 in) Weight 0.26 kg (0.58 lb)
4 Test & Inspection AFLglobal.com | 800.235.3423 Fiber Identification MFIS Multi-Fiber Identification System ©2020, AFL, all rights reserved. MFIS-00-2000 Revision AB, 2020-11-19 Specifications are subject to change without notice. Qualificati ons CATEGORY REGULATION/STANDARD QUALIFICATION CE Marking EU Compliant to relevant EU Directives on health, safety, and environmental protection, and certified with CE marking Safety/EMC/EMI IEC Compliant to IEC 61010-1 for safety requirements for electrical equipment EN Compliant to EN 61010-1 for safety requirements for electrical equipment IEC Compliant to IEC 61326-1 for EMC requirements for electrical equipment EN Compliant to EN 61326-1 for EMC requirements for electrical equipment EN Compliant to EN 55011 for EMC requirements for industrial, scientific and medical equipment FDA Compliant to code of federal regulations FDA 21 CFR 1040.10 and 1040.11 on laser products IEC Compliant to IEC 60825-1 for safety of laser products RoHS EU Compliant to EU regulations Directive 2011/65/EU (RoHS 2) and Directive 2015/863 (RoHS 3) Generic Requirement IEC Compliant to IEC 61315 for requirements on calibration of fibre-optic power meters Contact Sales@AFLglobal.com to schedule a demonstration or learn how to buy. Visit www.AFLglobal.com/Test to learn more about OPM5 and OPM4 optical power meters. International Sales and Service Contact Information available at www.AFLglobal.com/Test/Contacts . Recommended Products One-Click ® Cleaners • Patented single-action • Variety of sizes and types • Low cost per clean FOCIS Flex Connector Inspection • Self-contained, tether-free, hand-held • Auto-focus and auto-centering for fast, easy inspection • IEC, IPC and user-defined pass/fail analysis
Features:
- Easy to use
- Powered by common batteries
- Hand-held and lightweight
- Three-year calibration interval
Applications:
- Network construction detection
- Various connectors for easy application
- Optimized for use on 250 ?m, 900 ?m and ribbon fiber
Multi-Fiber network construction is time consuming, complicated, and often built by more than one crew with mixed sets of documentation. However carefully the build-out is done, mistakes such as mislabeling can happen. How can the network operator have full confidence in their network continuity? AFL’s Multi-Fiber Identification System (MFIS) can provide 100% multi-fiber network continuity assurance and senior management peace of mind. The MFIS test system is a simple user-friendly way to verify network construction quickly, correctly, and efficiently.
Designed to address both the service provider and enterprise markets, the MFIS test system, with its embedded digital coding, called Fiber ID, is used during and after multi-fiber network construction activities to give managers confidence and peace of mind with respect to fiber network documentation accuracy.
MFT — Multi-fiber Tracer
The MFT is a single power (MTP), twelve-fiber output 1550 nm source. It is designed around 12 discrete laser sources (1550 nm singlemode) tied to an MTP fan-out connector. It is packaged in a light and sturdy case. One single button operation is designed to quickly send laser light with embedded Fiber ID signals down the network for MFI (Multi-Fiber Identifier) and/or MFP (Multi-Fiber Power Meter) to provide automatic fiber identification.
MFI — Multi-fiber Identifier
MFI is designed to detect the presence of digitally coded laser light in the optical fiber network under test. The unit is activated by inserting the fiber under test into the clamp and pulling the trigger, located on the underside of the MFI. The LCD displays the fiber identification number.
MFI detects the digitally coded data bursts transmitted by the MFT when the MFI is clamped on the fiber under test.
MFP — Multi-fiber Power Meter
MFP is designed to detect the presence of digitally coded laser light emitted from the MFT while in Fiber ID mode. It is also designed to use as a regular power meter.
Ordering Information
| DESCRIPTION |
AFL NO. |
| Basic Kit: includes MFT, MFI, 12-fiber cable, One-Click Cleaner MPO, One-Click Cleaner Mini-100 |
MFTI-12-BAS |
| Basic Kit: includes MFT, MFP, 12-fiber cable, One-Click Cleaner MPO, One-Click Cleaner Mini-100 |
MFTP1-12-BAS |
| Basic Kit: includes MFT, MFI, MFP 12-fiber cable, One-Click Cleaner MPO, One-Click Cleaner Mini-100 |
MFTIP1-12-BAS |
| Multi-Fiber Identifier, no case |
MFI1-00-0900MR |
| Multi-Fiber Power Meter, no case |
MFP1-12-0900MR |
| ACCESSORIES |
|
| Cable, MPO/APC(M)-SC/APC, 12-fiber, SM, FANOUT, 3 METER |
8700-00-0198MR |
| Cable, MPO/APC(M)-SC/UPC, 12-fiber, SM, FANOUT, 3 METER |
8700-00-0200MR |
| Cable, MPO/APC(M)-LC/UPC, 12-fiber, SM, FANOUT, 3 METER |
8700-00-0201MR |
| One-Click Cleaner MPO (500 cleans) |
8500-05-0030MZ |
| One-Click Mini-100 SC, ST, FC (100+ cleans) |
8500-05-0005MZ |

OFI 200D Optical Fiber Identifier,OFI 400 Series Optical Fiber Identifier,OFI BIPM and OFI BIPMe Optical Fiber Identifiers,VFI4 Visual Fault Identifier,MT Tracer 12Fiber VFL and Display
2556