Optische Lichtquellen und Leistungsmessgeräte der Contractor-Serie: handtellergroße Geräte zum Testen von Singlemode- und Multimode-Glasfasernetzverbindungen. Mit einem Gewicht von nur 0,4 lb sind die Geräte der Contractor-Serie ideal für den Einsatz vor Ort.
250b59e9939b4ab7828c992e2055565b,b8a3e2e239734e2199b5e0047aa03b01
AFLglobal.com 1 (800) 235-3423 ©2021-2024, AFL, all rights reserved. CS00-00-2000 Revision AD 2024-12-03 Specifications are subject to change without notice . Test and Inspection Contractor Series Light Sources and Power Meters 1 Applications • Link loss measurements • Certify SM and MM links to industry standards • Continuity check and fiber identification prior to fusion splicing CSS1-MM LED Source CSS1-SM Laser Source CSM1 Power Meter Contractor Series Light Sources and Power Meters are rugged test instruments designed with a simple user interface and backed by an industry-leading 5-year warranty. Both single-mode and multimode kit options provide tools for measuring network insertion loss, continuity checks, and fiber identification. Features • Palm-sized rugged, dependable tools • Industry-leading 5-year warranty • Cost-effective, easy to use • Auto-off to maximize battery life on Power Meter • Large readable in bright or dim conditions CSM1 Power Meter • Four models provide wide wavelength and power level ranges • Stores optical references for each calibrated wavelength • Auto-detects Test Tones for use in fiber identification • Optical input port accepts a variety of thread-on adapter caps CSS1-SM Laser Source • 1310 nm and 1550 nm LASER output from single test port • Output port accepts UCI threaded adapters (FC, SC, ST, LC) for flexibility and access to launch fiber for cleaning and inspection CSS1-MM LED Source • 850 nm and 1300 nm LED output from single test port • 50 μm and 62.5 μm mandrels included • Test Tones (2000, 1000, 330, 270 Hz) for fiber identification – Use power meters when technician has fiber end access CSS1 Sources Transmit: • CW continuous wave output (DC) • Test Tones (2000, 1000, 330, 270 Hz) for fiber identification – Use power meters when technician has fiber end access – Use OFI (optical fiber identifier) for mid-span testing
AFLglobal.com 1 (800) 235-3423 ©2021-2024, AFL, all rights reserved. CS00-00-2000 Revision AD 2024-12-03 Specifications are subject to change without notice . Test and Inspection Contractor Series Light Sources and Power Meters 2 Contractor Series Models Power Meter Models Calibrated Wavelengths (nm) Target Applications CSM1-3 850, 1300, 1310, 1490, 1550, 1625 Single-mode Measurements CSM1-4 850, 980, 1310, 1490, 1550, 1625 High Power Single-mode Measurements Specifications a Optical Specifications: CSM1 Power Meter Model CSM1-3 CSM1-4 Calibrated Wavelengths 850, 1300, 1310, 1490, 1550, 1625 nm 850, 980, 1310, 1490, 1550, 1625 nm Detector Type InGaAs Filtered InGaAs Measurement Range +6 to -70 dBm +26 to -50 dBm Tone Detect Range +6 to -50 dBm +6 to -45 dBm for 850 nm +6 to -30 dBm +6 to -25 dBm for 850 nm Accuracy b ±0.15dB (typical), ±0.3 dB Resolution 0.01 dB Measurement Units dB, dBm, μW Light Sources Models Fiber Type Wavelengths (nm) Target Applications CSS1-SM SM 1310, 1550 SM Networks, LAN/WAN Testing CSS1-MM MM 850, 1300 Ethernet, Token Ring, and FDDI Fiber Links Loss Test Kits Models Fiber Type Power Meter Light Source Dynamic Range (dB) CKS-3 SM CSM1-3 CSS1-SM 70 @ 1310/1550 nm, on 9/125 single-mode fiber CKM-3 MM CSM1-3 CSS1-MM 40 @ 850/1300 nm, on 62.5/125 multimode fiber CKSM-2 SM MM CSM1-3 CSS1-SM CSS1-MM 60 @ 1310/1550 nm, on 9/125 single-mode fiber 40 @ 850/1300 nm, on 62.5/125 multimode fiber Optical Specifications: CSS1 Light Source Model CSS1-SM (Single Port) CSS1-MM (Single-Port) Wavelength 1310 ±20 nm 1550 ±20 nm 850 ±20 nm 1300 ±20 nm Spectral Width 5 nm (max) 45 nm (typ) 120 nm (typ) Emitter Type. Safety Class Laser. Class I FDA 21 CFR 1040.10 & 1040.11, IEC 60825-1: 2007-03 LED, Class I FDA 21 CFR 1040.10 & 1040.11, IEC 60825-1: 2007-03 Output Power ≥0.0 dBm into 9/125 fiber ≥-20.0 dBm into 62.5/125 fiber Output Stability c ±0.05 dB over 1 hour; ±0.15 dB over 8 hours ±0.1 dB over 1 hour; ±0.15 dB over 8 hours Tone Output 2000, 1000, 330, 270 Hz General Specifications Model CSM1 CSS1-SM CSS1-MM Output Connector Supports Most Industry Standard Connectors SC, FC, ST, LC SC Fixed Power 2 AA batteries 2 AA batteries 2 AA batteries Battery Life >300 hours 75 hours (typical) 30 hours (typical) Operating Temperature -10 °C to 50 °C, 90 % RH (non-condensing) Storage Temperature -30 °C to 60 °C, 90 % RH (non-condensing) Size (H x W x D) 11.4 x 6.4 x 3.2 cm (4.5 x 2.5 x 1.3 in) without boot Weight 0.29 kg (0.65 lb) without boot a. Notes: b. a. All specifications at 25 °C unless otherwise specified. c. b. Accuracy measured at 25 °C and -10 dBm per N.I.S.T. standards. d. c. After typical 30 second warm up.
AFLglobal.com 1 (800) 235-3423 ©2021-2024, AFL, all rights reserved. CS00-00-2000 Revision AD 2024-12-03 Specifications are subject to change without notice . Test and Inspection Contractor Series Light Sources and Power Meters 3 Ordering Information Each Contractor Series Kit ships with adapter caps for all included instruments, AA alkaline batteries, user guide, and carry case with room for optional cleaning supplies (see below). Fiber mandrels (50 micron and 62.5 micron) are included with CKSM-2 and CKM-2 kits. When purchased separately, CSM1 power meters and CSS1 light sources ship with connector adapter, AA alkaline batteries, user guide, and carry case. Fiber mandrels (50 micron and 62.5 micron) are included with CSS1-MM units. Test jumpers are required for operation (purchased separately). Test jumpers with a variety of connector styles and fiber types and adapter caps for most common connectors may be purchased from AFL. Models and Configurations Model Number Includes CKS-3-cc (cc = FC or SC) Single-Mode Test Kit. Available with FC or SC connectors adapters. CKM-3 Multimode Test Kit. Available with SC connector adapters. CKSM-2 Single-mode and Multimode Test kIt. Available with SC connector adapters. CSS1-SM-cc (c = FC, SC, ST, or LC) Single-mode LASER Source. Available with FC, SC, ST, or LC connector adapters. CSS1-MM Multimode LED Source. Available with SC connector adapter.. CSM1-3-cc (cc = *) InGaAs Detector for single-mode applications. CSM1-4-cc (cc = *) High Power InGaAs Detector for single-mode applications. * For CSM1 power meters, cc = FC, SC, ST, LC, 2.5 mm, 1.25 mm. Other connector styles are available; see accessories section. CSM1 Power Meter Adapter Caps AFL NO. Description 8800-00-0214 2.5 mm Universal (accepts FC, SC, and ST ferrules) 8800-00-0224 1.25 mm Universal (accepts LC and MU ferrules) 8800-00-0200 FC 8800-00-0209 SC 8800-00-0202 ST 8800-00-0225 LC simplex 8800-00-0221 E-2000 8800-00-0219 2.5 mm open Universal, Accepts SC duplex, OptiTap connector 8800-00-0203 SMA 8800-00-0201 D4 8800-00-0204 Biconic CSS1-SM Single-mode Light Source Accessories AFL NO. Description 2900-50-0002MR FC UCI connector adapter 2900-50-0003MR SC UCI connector adapter 2900-50-0004MR ST UCI connector adapter 2900-50-0006MR LC UCI connector adapter 8800-00-0072PR Universal flip-top dust cap for UCI outputs
AFLglobal.com 1 (800) 235-3423 ©2021-2024, AFL, all rights reserved. CS00-00-2000 Revision AD 2024-12-03 Specifications are subject to change without notice . Test and Inspection Contractor Series Light Sources and Power Meters 4 Qualificati ons Category Regulation/Standard Qualification CE Marking EU Compliant to relevant EU Directives on health, safety, and environmental protection, and certified with CE marking Safety/EMC/EMI IEC Compliant to IEC 61010-1 for safety requirements for electrical equipment EN Compliant to EN 61010-1 for safety requirements for electrical equipment IEC Compliant to IEC 61326-1 for EMC requirements for electrical equipment EN Compliant to EN 61326-1 for EMC requirements for electrical equipment EN Compliant to EN 55011 for EMC requirements for industrial, scientific and medical equipment FDA Compliant to code of federal regulations FDA 21 CFR 1040.10 and 1040.11 on laser products IEC Compliant to IEC 60825-1 for safety of laser products RoHS EU Compliant to EU regulations Directive 2011/65/EU (RoHS 2) and Directive 2015/863 (RoHS 3) Test Method TIA Compliant to TIA-568.3-D for test and measurement requirements for premises optical fiber cabling and components* IEC Compliant to IEC 11801 for test and measurement requirements for optical fiber cabling for use within premises* EN Compliant to EN 50173 for test and measurement requirements for optical fiber cabling for use within premises* AS/NZS Compliant to AS/NZS 3080 for test and measurement requirements for optical fiber cabling for use within premises* TIA Compliant to TIA-526-7 for test procedures for installed optical fiber cable plant TIA Compliant to TIA-526-14 for test procedures for installed optical fiber cable plant* IEC Compliant to IEC 14763-3 for systems and methods for the inspection and testing of installed optical fiber cabling* AS/NZS Compliant to AS/NZS 14763.3 for systems and methods for the inspection and testing of installed optical fiber cabling* IEC Compliant to IEC 61280-4-1 for test procedures for installed optical fiber cable plant* IEC Compliant to IEC 61280-4-2 for test procedures for installed optical fiber cable plant Generic Requirement IEC Compliant to IEC 61315 for requirements on calibration of fibre-optic power meters * A complementary encircled flux mode conditioner may be needed to comply with encircled flux launch conditions for testing multimode optical fiber cabling and components . Contact Sales@AFLglobal.com to schedule a demonstration or learn how to buy. Visit www.AFLglobal.com/Test to learn more about Contractor Series light sources and power meters. International Sales and Service Contact Information available at www.AFLglobal.com/Test/Contacts Recommended Products One-Click ® Cleaners • Patented single-action • Variety of sizes and types • Low cost per clean OFI-BIPM Optical Fiber Identifier • World class signal sensitivity • Trigger lock, positive stop for optimum detection • Integrated optical power meter option
Merkmale:
- Handflächengroße, robuste und zuverlässige Werkzeuge
- Branchenführende 5-Jahres-Garantie
- Kostengünstig, einfach zu bedienen
- Automatische Abschaltung zur Maximierung der Batterielebensdauer des Power Meters
Anwendungen:
- Messungen des Verbindungsverlustes
- Zertifizierung von SM & MM-Verbindungen nach Industriestandards
- Kontinuitätsprüfung und Faseridentifizierung vor dem Fusionsspleißen
Die Lichtquellen und Leistungsmessgeräte der Contractor-Serie sind robuste Prüfgeräte mit einer einfachen Benutzeroberfläche und einer branchenführenden 5-Jahres-Garantie. Sowohl die Singlemode- als auch die Multimode-Kit-Optionen bieten Werkzeuge zur Messung der Netzwerkeinfügedämpfung, zur Durchgangsprüfung und zur Faseridentifizierung.
CSM1 Leistungsmessgerät
Optischer Eingangsanschluss für eine Vielzahl von aufschraubbaren Adapterkappen
CSS1-SM Laserquelle
Eine vollständige Liste der Modelle und des optionalen Zubehörs finden Sie im technischen Datenblatt. - Vier Modelle bieten weite Wellenlängen- und Leistungspegelbereiche
- Speichert optische Referenzen für jede kalibrierte Wellenlänge
- Automatische Erkennung von Testtönen für die Faseridentifikation
CSS1-SM Laserquelle
- 1310 nm und 1550 nm LASER-Ausgang von einem einzigen Testanschluss
- Der Ausgangsanschluss kann mit UCI-Gewindeadaptern (FC, SC, ST, LC) bestückt werden und bietet so Flexibilität und Zugang zur Einspeisung der Faser für Reinigung und Inspektion
- 850 nm und 1300 nm LED-Ausgang von einem einzigen Testport
- 50 μm und 62,5 μm Mandrels im Lieferumfang enthalten
- Testtöne (2000, 1000, 330, 270 Hz) zur Faseridentifikation
- Verwendung von Leistungsmessern, wenn der Techniker Zugang zum Faserende hat
CSS1-Quellen übertragen:
- CW-Dauerstrich-Ausgang (DC)
- Testtöne (2000, 1000, 330, 270 Hz) zur Faseridentifikation
- Verwendung von Leistungsmessern, wenn der Techniker Zugang zum Faserende hat
- Verwendung von OFI (Optical Fiber Identifier) für Tests in der Mitte des Kabelabschnitts
- Verwendung von Leistungsmessern, wenn der Techniker Zugang zum Faserende hat
EF-konforme Lichtquellen und Testkits mit eingekreisten Flussmitteln,Testkits für optische Verluste SLP56D SLP5,OLS7 Dreifach-Wellenlängen-Laserquellen,Umschlossene Lichtquellen mit EF-konformem Lichtstrom,OLS-Serie Lichtquellen,OLS2 Duale Laserquelle mit Wellen-ID,FlowScout™ PON Optical Power Meter,OPM5 und OPM4 Optische Leistungsmessgeräte,OPM5 Optisches Leistungsmessgerät mit Datenspeicher,Leistungsmessgeräte-Anschlussadapter
1100
Close
Lichtquellen und Leistungsmessgeräte der Contractor-Serie
Merkmale:
- Handflächengroße, robuste und zuverlässige Werkzeuge
- Branchenführende 5-Jahres-Garantie
- Kostengünstig, einfach zu bedienen
- Automatische Abschaltung zur Maximierung der Batterielebensdauer des Power Meters
Anwendungen:
- Messungen des Verbindungsverlustes
- Zertifizierung von SM & MM-Verbindungen nach Industriestandards
- Kontinuitätsprüfung und Faseridentifizierung vor dem Fusionsspleißen
PRODUCT DESCRIPTION
Die Lichtquellen und Leistungsmessgeräte der Contractor-Serie sind robuste Prüfgeräte mit einer einfachen Benutzeroberfläche und einer branchenführenden 5-Jahres-Garantie. Sowohl die Singlemode- als auch die Multimode-Kit-Optionen bieten Werkzeuge zur Messung der Netzwerkeinfügedämpfung, zur Durchgangsprüfung und zur Faseridentifizierung.
CSM1 Leistungsmessgerät
Optischer Eingangsanschluss für eine Vielzahl von aufschraubbaren Adapterkappen
CSS1-SM Laserquelle
Eine vollständige Liste der Modelle und des optionalen Zubehörs finden Sie im technischen Datenblatt. - Vier Modelle bieten weite Wellenlängen- und Leistungspegelbereiche
- Speichert optische Referenzen für jede kalibrierte Wellenlänge
- Automatische Erkennung von Testtönen für die Faseridentifikation
CSS1-SM Laserquelle
- 1310 nm und 1550 nm LASER-Ausgang von einem einzigen Testanschluss
- Der Ausgangsanschluss kann mit UCI-Gewindeadaptern (FC, SC, ST, LC) bestückt werden und bietet so Flexibilität und Zugang zur Einspeisung der Faser für Reinigung und Inspektion
- 850 nm und 1300 nm LED-Ausgang von einem einzigen Testport
- 50 μm und 62,5 μm Mandrels im Lieferumfang enthalten
- Testtöne (2000, 1000, 330, 270 Hz) zur Faseridentifikation
- Verwendung von Leistungsmessern, wenn der Techniker Zugang zum Faserende hat
CSS1-Quellen übertragen:
- CW-Dauerstrich-Ausgang (DC)
- Testtöne (2000, 1000, 330, 270 Hz) zur Faseridentifikation
- Verwendung von Leistungsmessern, wenn der Techniker Zugang zum Faserende hat
- Verwendung von OFI (Optical Fiber Identifier) für Tests in der Mitte des Kabelabschnitts
- Verwendung von Leistungsmessern, wenn der Techniker Zugang zum Faserende hat