El cable de tubo envolvente (WTC) de 200 µm con SpiderWeb Ribbon® (SWR) es un cable de planta exterior de altísima densidad diseñado específicamente para los mercados de fibra hasta el hogar (FTTH) o de acceso.
6c56315cad1a4760a75ffcf044e23aae
1 FIBER OPTIC CABLE Fiber Optic Cable © 2019, AFL, all rights reserved. PP-1-00169, Revision 4, 8.10.2022 Specifications are subject to change without notice. AFLglobal.com | 800.235.3423 continued The 200 μm fiber/250 μm pitch Wrapping Tube Cable (WTC), with SpiderWeb Ribbon ® (SWR ® ), is an ultra-high density outside plant cable designed specifically for fiber-to-the-home (FTTH) or access markets. It is compliant with the latest issue of the outside plant cable standard, Telcordia GR-20. With an ultra-high density and a new ribbon technology called SpiderWeb Ribbon ® , WTC provides the smallest cable diameter and lowest weight, high-fiber count ribbon cable in the industry. WTC with SWR ® cables are available in fiber counts of 864, 1,728, 3,456 and 6,912. SWR ® is a bonded fiber ribbon design allowing for either a highly efficient ribbon splicing or an individual fiber breakout splicing process. This flexibility allows for a single cable design to cover a diverse set of applications from access networks to high-fiber count mass fusion splicing. With the ability to roll and conform, the SWR ® provides for ultra-high density packaging in the WTC. SWR Technology 12F SWR Multiple 12F SWR Bundle Non-armored (864F, 1728F, 3456F and 6912F) Rip cord Water blocking tape SWR bundled unit Strength member (FRP) Sheath (PE, Black) Rip cord Wrapping Tube Cable (WTC) with SpiderWeb Ribbon ® (SWR ® ) – 200 μm Fiber/250 μm Pitch Applications • Data Center Inter-building Connections • Access Provider Metro Rings • Service Provider FTTx • Cable TV Subscriber Networks • Metro Rail Track-side Network Links • Suitable for Aerial Lashing, Pulled-in-duct, Air-Jetted-in-Duct • Campus LAN Features • Collapsible ribbon reduces size of cable compared to other encapsulated or pliable ribbon technologies • Design optimizes the fiber packing density making WTC-SWR cables the smallest ribbon cables without compromising robustness of the cable • Small-diameter cable allows more optical fibers to be placed into crowded or limited- space pathways • Water-blocked core • Light weight for easy handling in the field compared to traditional cables • Completely Gel-free for reduced time to access fiber and prep for splicing
© 2019, AFL, all rights reserved. PP-1-00169, Revision 4, 8.10.2022 Specifications are subject to change without notice. AFLglobal.com | 800.235.3423 2 FIBER OPTIC CABLE Fiber Optic Cable Wrapping Tube Cable (WTC) with SWR ® – 200 μm Fiber/250 μm Pitch Mechanical Data—Non-Armored DESCRIPTION FIBER COUNT BINDER UNIT NOMINAL DIAMETER WEIGHT SHORT TERM/INSTALLATION LONG TERM/STORAGE/STATIC inches (mm) lbs/1,000 ft (kg/km) MAX TENSILE LOAD lbs (N) MIN BEND RADIUS inches (mm) MAX TENSILE LOAD lbs (N) MIN BEND RADIUS inches (mm) LWSE-864-BE-C-72-12-00N1D-* 864 12 X 72F 0.63 (16.0) 124 (185) 607 (2700) 12.6 (320) 182 (810) 9.5 (241) LWSE-1728-BE-C-144-12-00N1D-* 1728 12 X 144F 0.85 (21.5) 202 (300) 607 (2700) 16.9 (430) 182 (810) 12.7 (323) LWSE-3456-BE-C-144-24-00N1D-* 3456 24 X 144F 1.04 (26.5) 292 (435) 607 (2700) 20.9 (530) 182 (810) 15.7 (399) LWSE-6912-BE-C-288-24-00N1D-* 6912 24 X 288F 1.38 (35.0) 514 (765) 607 (2700) 27.6 (700) 182 (810) 20.7 (525) Optical Fiber FIBER COUNT FIBER DIA. FIBER PITCH FIBER DESIGNATOR MFD MAXIMUM ATTENUATION (CABLED) dB/km 1310 nm 1383 nm 1550 nm Fujikura SR15E-200 (864, 1728, 3456, 6912) 200 μm 250 μm BE (ITU-T G.652.D and G.657.A1) 8.6 ± 0.4 μm ≤ 0.35 dB/km ≤ 0.35 dB/km ≤ 0.25 dB/km Stripe Ring Fiber Identification — 6,912 R NO. STRIPE RING MARKING R NO. STRIPE RING MARKING R NO. STRIPE RING MARKING R NO. STRIPE RING MARKING 1 7 13 19 2 8 14 20 3 9 15 21 4 10 16 22 5 11 17 23 6 12 18 24 Stripe Ring Fiber Identification — 864, 1728, 3456 R NO. STRIPE RING MARKING R NO. STRIPE RING MARKING R NO. STRIPE RING MARKING 1 5 9 2 6 10 3 7 11 4 8 12 * NOTE: To designate length markings in AFL No., replace asterisk * with (FT) for Feet or (M) for Meters. Contact AFL for further details. Qualifications GOVERNING BODY STANDARD CODE COMPONENT Telcordia GR-20 Fiber Optic Cable Temperature Specifications TEMPERATURE RANGE OPERATION -40ºF to +158ºF (-40ºC to +70ºC) STORAGE -40ºF to +158ºF (-40ºC to +70ºC) INSTALLATION -22ºF to +140ºF (-30ºC to +60ºC) FIBER COUNT BINDER UNIT (BU) RING MARKINGS 864F 12 Binder Units 1 2 3 4 5 6 7 8 9 10 11 12 1-6 Ring Marking 1728F 12 Binder Units 1 2 3 4 5 6 7 8 9 10 11 12 1-12 Ring Marking 3456F 24 Binder Units* 1 2 3 4 5 6 7 8 9 10 11 12 1-12 Ring Marking 1-12 Ring Marking 6912F 24 Binder Units* 1 2 3 4 5 6 7 8 9 10 11 12 1-24 Ring Marking 1-24 Ring Marking *For binder units 13-24, the second binder unit is clear 13 13 14 14 15 15 16 16 17 17 18 18 19 19 20 20 21 21 22 22 23 23 24 24 13 13 14 14 15 15 16 16 17 17 18 18 19 19 20 20 21 21 22 22 23 23 24 24
3 FIBER OPTIC CABLE Fiber Optic Cable © 2022, AFL, all rights reserved. PP-1-00194, Revision 3, 10.27.2023 Specifications are subject to change without notice. AFLglobal.com | 800.235.3423 continued The 200 μm fiber/200 μm pitch Wrapping Tube Cable (WTC) with SpiderWeb Ribbon ® (SWR ® ) is an ultra-high density outside plant (OSP) cable designed specifically for fiber-to-the-home (FTTH) or access markets. It is compliant with the latest issue of the outside plant cable standard, Telcordia GR-20. With an ultra-high density and a new ribbon technology called SpiderWeb Ribbon ® , WTC provides the smallest cable diameter and lowest weight, high-fiber count ribbon cable in the industry. WTC with SWR ® cables are available in fiber counts of 864, 1,728, 3,456 and 6,912. SWR ® is a bonded fiber ribbon design allowing for either a highly efficient ribbon splicing or an individual fiber breakout splicing process. This flexibility allows for a single cable design to cover a diverse set of applications from access networks to high-fiber count mass fusion splicing. With the ability to roll and conform, the SWR ® provides for ultra-high density packaging in the WTC. SWR Technology 12F SWR Multiple 12F SWR Bundle Non-armored (864F, 1728F, 3456F and 6912F) Rip cord Water blocking tape SWR bundled unit Strength member (FRP) Sheath (PE, Black) Rip cord OSP Wrapping Tube Cable (WTC) with SpiderWeb Ribbon ® (SWR ® ) – 200 μm Fiber/200 μm Pitch Applications • Data Center Inter-building Connections • Access Provider Metro Rings • Service Provider FTTx • Cable TV Subscriber Networks • Metro Rail Track-side Network Links • Suitable for Aerial Lashing, Pulled-in-duct, Air-Jetted-in-Duct • Campus LAN Features • Collapsible ribbon reduces size of cable compared to other encapsulated or pliable ribbon technologies • Design optimizes the fiber packing density making WTC-SWR cables the smallest ribbon cables without compromising robustness of the cable • Small-diameter cable allows more optical fibers to be placed into crowded or limited- space pathways • Water-blocked core • Light weight for easy handling in the field compared to traditional cables • Completely Gel-free for reduced time to access fiber and prep for splicing
© 2022, AFL, all rights reserved. PP-1-00194, Revision 3, 10.27.2023 Specifications are subject to change without notice. AFLglobal.com | 800.235.3423 4 FIBER OPTIC CABLE Fiber Optic Cable OSP Wrapping Tube Cable (WTC) with SWR ® – 200 μm Fiber/200 μm Pitch Mechanical Data—Non-Armored DESCRIPTION FIBER COUNT BINDER UNIT NOMINAL DIAMETER WEIGHT SHORT TERM/DYNAMIC/ INSTALLATION LONG TERM/STORAGE/STATIC inches (mm) lbs/1,000 ft (kg/km) MAX TENSILE LOAD lbs (N) MIN BEND RADIUS inches (mm) MAX TENSILE LOAD lbs (N) MIN BEND RADIUS inches (mm) LWSE-864-BD-C-72-12-00N1D-* 864 12 X 72F 0.59 (15.0) 114 (170) 607 (2700) 11.8 (300) 182 (810) 8.9 (225) LWSE-1728-BD-C-144-12-00N1D-* 1728 12 X 144F 0.75 (19.0) 178 (265) 607 (2700) 15.0 (380) 182 (810) 11.2 (285) LWSE-3456-BD-C-144-24-00N1D-* 3456 24 X 144F 1.00 (25.5) 302 (450) 607 (2700) 20.1 (510) 182 (810) 15.1 (383) LWSE-6912-BD-C-288-24-00N1D-* 6912 24 X 288F 1.17 (29.8) 430 (640) 607 (2700) 23.5 (596) 182 (810) 17.6 (447) Optical Fiber FIBER COUNT FIBER DIA. FIBER PITCH FIBER DESIGNATOR MFD MAXIMUM ATTENUATION (CABLED) dB/km 1310 nm 1383 nm 1550 nm Fujikura SR15E-P200 (864F, 1728F, 3456F) 200 μm 200 μm BD (ITU-T G.652.D & G.657.A1) 8.6 ± 0.4 μm ≤ 0.40 ≤ 0.40 ≤ 0.30 Fujikura BIS-B-P200 (6912F) 200 μm 200 μm BB (ITU-T G.652.D & G.657.A2) 8.6 ± 0.4 μm ≤ 0.40 ≤ 0.40 ≤ 0.30 Stripe Ring Fiber Identification — 6,912 R NO. STRIPE RING MARKING R NO. STRIPE RING MARKING R NO. STRIPE RING MARKING R NO. STRIPE RING MARKING 1 7 13 19 2 8 14 20 3 9 15 21 4 10 16 22 5 11 17 23 6 12 18 24 Stripe Ring Fiber Identification — 864, 1728, 3456 R NO. STRIPE RING MARKING R NO. STRIPE RING MARKING R NO. STRIPE RING MARKING R NO. STRIPE RING MARKING 1 4 7 10 2 5 8 11 3 6 9 12 * NOTE: To designate length markings in AFL No., replace asterisk * with (FT) for Feet or (M) for Meters. Contact AFL for further details. Qualifications GOVERNING BODY STANDARD CODE COMPONENT Telcordia GR-20 Fiber Optic Cable Temperature Specifications TEMPERATURE RANGE OPERATION -40ºF to +158ºF (-40ºC to +70ºC) STORAGE -40ºF to +158ºF (-40ºC to +70ºC) INSTALLATION -22ºF to +140ºF (-30ºC to +60ºC) FIBER COUNT BINDER UNIT (BU) RING MARKINGS 864F 12 Binder Units 1 2 3 4 5 6 7 8 9 10 11 12 1-6 Ring Marking 1728F 12 Binder Units 1 2 3 4 5 6 7 8 9 10 11 12 1-12 Ring Marking 3456F 24 Binder Units* 1 2 3 4 5 6 7 8 9 10 11 12 1-12 Ring Marking 1-12 Ring Marking 6912F 24 Binder Units* 1 2 3 4 5 6 7 8 9 10 11 12 1-24 Ring Marking 1-24 Ring Marking *For binder units 13-24, the second binder unit is clear 13 13 14 14 15 15 16 16 17 17 18 18 19 19 20 20 21 21 22 22 23 23 24 24 13 13 14 14 15 15 16 16 17 17 18 18 19 19 20 20 21 21 22 22 23 23 24 24
Características:
- Construcción preparada para el acceso (ARC)
- Tecnología de fibra óptica SpiderWeb Ribbon® (SWR®)
- Densidad de fibra significativamente mayor en comparación con los cables de cinta tradicionales
- Diámetros y pesos de cable más pequeños
- Tecnología de bloqueo de agua completamente seca
- Paquetes de cinta compactos
- Paquetes no blindados
- Totalmente calificado según Telcordia GR-20
Aplicaciones:
- Conexiones entre centros de datos
- Anillos de metro del proveedor de acceso
- Proveedor de servicios FTTx
- Redes de abonados a la televisión por cable
- Enlaces de red en las vías del metro
- Adecuado para el amarre aéreo, tirado en el conducto, tirado por aire en el conducto
- LAN de campus
El cable de tubo envolvente (WTC) de 200 µm, con cinta SpiderWeb® (SWR®), es un cable de planta exterior de altísima densidad diseñado específicamente para los mercados de fibra hasta el hogar (FTTH) o de acceso. Cumple con la última edición de la norma para cables de planta externa, Telcordia GR-20. Con una densidad ultra alta y una nueva tecnología de cinta llamada SpiderWeb Ribbon®, WTC ofrece el cable de cinta de menor diámetro y menor peso, con un alto número de fibras, del sector. Los cables WTC con SWR®
están disponibles con un número de fibras de 3.456 y 6.912. SWR® es un diseño de cinta de fibra unida que permite un empalme de cinta altamente eficiente o un proceso de empalme de ruptura de fibra individual. Esta flexibilidad permite que un solo diseño de cable cubra un conjunto diverso de aplicaciones, desde redes de acceso hasta empalmes de fusión masiva con alto número de fibras. Con la capacidad de enrollarse y conformarse, el SWR®
proporciona un embalaje de ultra alta densidad en el WTC.Serie LMV OFNR IO MicroCore,Serie LMZ OFNG LS IO MicroCore,Cable de fibra óptica soplada MicroCore,Cable de tubo ignífugo WTC con cinta de tela de araña SWR,Cable de tubo envolvente WTC con SWR
2656
Close
Cable de tubo envolvente (WTC) de 200 µm con SWR®.
Características:
- Construcción preparada para el acceso (ARC)
- Tecnología de fibra óptica SpiderWeb Ribbon® (SWR®)
- Densidad de fibra significativamente mayor en comparación con los cables de cinta tradicionales
- Diámetros y pesos de cable más pequeños
- Tecnología de bloqueo de agua completamente seca
- Paquetes de cinta compactos
- Paquetes no blindados
- Totalmente calificado según Telcordia GR-20
Aplicaciones:
- Conexiones entre centros de datos
- Anillos de metro del proveedor de acceso
- Proveedor de servicios FTTx
- Redes de abonados a la televisión por cable
- Enlaces de red en las vías del metro
- Adecuado para el amarre aéreo, tirado en el conducto, tirado por aire en el conducto
- LAN de campus
PRODUCT DESCRIPTION
El cable de tubo envolvente (WTC) de 200 µm, con cinta SpiderWeb® (SWR®), es un cable de planta exterior de altísima densidad diseñado específicamente para los mercados de fibra hasta el hogar (FTTH) o de acceso. Cumple con la última edición de la norma para cables de planta externa, Telcordia GR-20. Con una densidad ultra alta y una nueva tecnología de cinta llamada SpiderWeb Ribbon®, WTC ofrece el cable de cinta de menor diámetro y menor peso, con un alto número de fibras, del sector. Los cables WTC con SWR®
están disponibles con un número de fibras de 3.456 y 6.912. SWR® es un diseño de cinta de fibra unida que permite un empalme de cinta altamente eficiente o un proceso de empalme de ruptura de fibra individual. Esta flexibilidad permite que un solo diseño de cable cubra un conjunto diverso de aplicaciones, desde redes de acceso hasta empalmes de fusión masiva con alto número de fibras. Con la capacidad de enrollarse y conformarse, el SWR®
proporciona un embalaje de ultra alta densidad en el WTC.