La fuente de luz de la serie OLS es una unidad de campo ideal para los técnicos que certifican redes monomodo y multimodo.
,b8a3e2e239734e2199b5e0047aa03b01
AFLglobal.com 1 (800) 235-3423 © 2021-2025, AFL, all rights reserved. OLS0-00-2000 Revision AC 2022-03-27 Specifications are subject to change without notice. Test and Inspection OLS Series Light Sources 1 AFL is a trusted supplier of optical testing equipment with more than 30 years of experience and tens of thousands of units in use in the field. AFL’s full range of light sources are used for testing single-mode and/or multimode fiber networks. Sources with wave ID can transmit two or more wavelengths simultaneously – decreasing test time and reducing user errors when paired with AFL wave ID power meters. Designed for the real world: AFL’s light sources were designed to meet the demands of the outside plant environment. They withstand the one-meter drop and have splash resistant controls that are easy to use, even with gloves on. Flexible and efficient: A range of field-swappable output adapters enables access for cleaning optical ports and supports multiple connector styles. The efficient design provides long test time from globally available AA batteries. External power adapter available for extended testing or lab situations. Reduce test time and errors: Wave ID (Dual or Single) decreases test time while reducing technician errors and CW mode provides continuous output (no encoding). Supported output modes: Test Tone (2000, 1000, 330, 270 Hz) for use in fiber identification with AFL brand power meters, OTDRs (with fiber end access) or Optical Fiber Identifier (OFI) products for non-intrusive, mid-span testing. Features • Rugged, dependable, and backed by industry-best 5-year warranty • Generates up to three Wave ID wavelengths simultaneously - slashing test time • Field-swappable connector adapters for maximum flexibility • Long battery life from globally available AA batteries Applications • Certify multimode and single-mode links per TIA/EIA standards • Link loss measurements • Pair with power meters, OTDRs or OFIs for testing • Fiber identification for splicing and continuity checking OLS2 Dual Optical Laser Source
2 AFLglobal.com 1 (800) 235-3423 © 2021-2025, AFL, all rights reserved. OLS0-00-2000 Revision AC 2022-03-27 Specifications are subject to change without notice. Test and Inspection OLS Series Light Sources 2 OLS Series Models and Applications Model MM / SM Wavelengths (nm) Applications OLS1-Dual MM 850, 1300 Ethernet, Token Ring, and FDDI Fiber Links OLS2-Dual SM 1310, 1550 SM Networks, LAN/WAN Testing Specifications a,e Optical Specifications - OLS2-Dual and OLS1-Dual Models Model OLS1-Dual (Single Port b ) OLS2-Dual (Single Port) Wavelength 850 ±30 nm 1300 +30/-20 nm 1310 ±20 nm 1550 ±20 nm Spectral Width 45 nm (typ); 60 nm (max) 120 nm (typ); 170 nm (max) 5 nm (max) Emitter Type LED Laser Safety Class Class I FDA 21 CFR 1040.10 and 1040.11, IEC 60825-1: 2007-03 Output Power >-20 dBm, 62.5 μm multimode c 0 dBm, 9 μm single-mode d Output Stability ±0.1 dB over 8 hours (after 5 minutes warm-up) ±0.05 dB over 1 hour (after 15 minutes warm-up) ±0.1 dB over 8 hours (after 15 minutes warm-up) Tone Output N/A 270 Hz, 330 Hz, 1 kHz, 2 kHz General Specifications: All OLS Models Available Adapters SC FC, ST, LC Power 2 AA batteries, optional AC adapter Battery Life SM port: 72 hours typical (40 hours minimum). MM port: 30 hours typical (20 hours minimum) Operating Temperature -10 °C to 50 °C, 95 % RH (non-condensing) Storage Temperature -30 °C to 60 °C, 95 % RH (non-condensing) Size (H x W x D) 14.0 x 8.1 x 3.8 cm (5.5 x 3.2 x 1.5 in) Weight 0.29 kg (0.65 lb) Notes: a. All specifications valid at 25°C unless otherwise specified. b. May be used to test 50 or 62.5 μm fiber with supplied mandrels. c. Output power will be approximately 3 dB less if a 50 μm mandrel-wrapped jumper is used instead of a 62.5 μm mandrel-wrapped jumper. d. Adjustable 2 dB. e. All OLS products come with the UPC optical port. Ordering Information When ordering, specify connector type at the end of model number (e.g. OLS2-DUAL-SC). All OLS models include protective rubber boot, 2 AA batteries, carry case. AC adapters are available (ordered separately), see table below. Test jumpers and connector adapters are required for operation (purchased separately). Test jumpers with a variety of connector styles and fiber types and adapter caps for most common connectors may be purchased from AFL. AFL NO. Output Wavelengths (nm) Output Ports Emitter Type Wave ID Transmit Available Connectors Power 850 1300 1310 1550 OLS1-DUAL 1 LED FC, SC, ST, LC (2) AA, AC OLS2-DUAL 1 Laser FC, SC, ST, LC (2) AA, AC
AFLglobal.com 1 (800) 235-3423 © 2021-2025, AFL, all rights reserved. OLS0-00-2000 Revision AC 2022-03-27 Specifications are subject to change without notice. Test and Inspection OLS Series Light Sources 3 OLS Connector Adapters and AC Adapter AFL NO. Description 2900-50-0002MR FC connector adapter 2900-50-0003MR SC connector adapter 2900-50-0004MR ST connector adapter 2900-50-0006MR LC connector adapter 8800-00-0072PR Universal flip-top dust cap for UCI outputs 4050-00-0119PR 100-240 VAC to 9 VDC, AC adapter Qualificati ons Category Regulation/Standard Qualification CE Marking EU Compliant to relevant EU Directives on health, safety, and environmental protection, and certified with CE marking Safety/EMC/EMI IEC Compliant to IEC 61010-1 for safety requirements for electrical equipment EN Compliant to EN 61010-1 for safety requirements for electrical equipment IEC Compliant to IEC 61326-1 for EMC requirements for electrical equipment EN Compliant to EN 61326-1 for EMC requirements for electrical equipment EN Compliant to EN 55011 for EMC requirements for industrial, scientific and medical equipment FDA Compliant to code of federal regulations FDA 21 CFR 1040.10 and 1040.11 on laser products IEC Compliant to IEC 60825-1 for safety of laser products RoHS EU Compliant to EU regulations Directive 2011/65/EU (RoHS 2) and Directive 2015/863 (RoHS 3) Test Method TIA Compliant to TIA-568.3-D for test and measurement requirements for premises optical fiber cabling and components* IEC Compliant to IEC 11801 for test and measurement requirements for optical fiber cabling for use within premises* EN Compliant to EN 50173 for test and measurement requirements for optical fiber cabling for use within premises* AS/NZS Compliant to AS/NZS 3080 for test and measurement requirements for optical fiber cabling for use within premises* TIA Compliant to TIA-526-7 for test procedures for installed optical fiber cable plant TIA Compliant to TIA-526-14 for test procedures for installed optical fiber cable plant* IEC Compliant to IEC 14763-3 for systems and methods for the inspection and testing of installed optical fiber cabling* AS/NZS Compliant to AS/NZS 14763.3 for systems and methods for the inspection and testing of installed optical fiber cabling* IEC Compliant to IEC 61280-4-1 for test procedures for installed optical fiber cable plant* IEC Compliant to IEC 61280-4-2 for test procedures for installed optical fiber cable plant * A complementary encircled flux mode conditioner may be needed to comply with encircled flux launch conditions for testing multimode optical fiber cabling and components Contact Sales@AFLglobal.com to schedule a demonstration or learn how to buy. Visit www.AFLglobal.com/Test to learn more about OLS series light sources. International Sales and Service Contact Information available at www.AFLglobal.com/Test/Contacts Recommended Products One-Click ® Cleaners • Patented single-action • Variety of sizes and types • Low cost per clean OFI-BIPM Optical Fiber Identifier • World class signal sensitivity • Trigger lock, positive stop for optimum detection • Integrated optical power meter option
Características:
- Resistente, fiable y respaldado por la mejor garantía del sector de 5 años
- Genera hasta tres longitudes de onda Wave ID simultáneamente, lo que reduce el tiempo de prueba
- Adaptadores de conector intercambiables en campo para una máxima flexibilidad
- Larga duración de las pilas AA disponibles en todo el mundo
Aplicaciones:
- Certificación de enlaces multimodo y monomodo según las normas TIA/EIA
- Mediciones de pérdida de enlaces
- Emparejamiento con medidores de potencia, OTDRs u OFIs para pruebas
- Identificación de fibras para empalmes y comprobación de la continuidad
AFL es un proveedor de confianza de equipos de pruebas ópticas con más de 30 años de experiencia y decenas de miles de unidades en uso sobre el terreno. La gama completa de fuentes de luz de AFL’se utiliza para probar redes de fibra monomodo y/o multimodo. Las fuentes con ID de onda pueden transmitir dos o más longitudes de onda simultáneamente – disminuyendo el tiempo de prueba y reduciendo los errores del usuario cuando se emparejan con medidores de potencia con ID de onda AFL.
Diseñado para el mundo real: Las fuentes de luz de AFL’han sido diseñadas para satisfacer las exigencias del entorno exterior de las plantas. Soportan la caída de un metro y tienen controles resistentes a las salpicaduras que son fáciles de usar, incluso con guantes.
Flexible y eficiente: Una gama de adaptadores de salida intercambiables sobre el terreno permite el acceso para la limpieza de los puertos ópticos y admite múltiples estilos de conectores. El eficiente diseño proporciona un largo tiempo de prueba con las pilas AA disponibles en todo el mundo. Adaptador de corriente externo disponible para pruebas prolongadas o situaciones de laboratorio.
Reduzca el tiempo de las pruebas y los errores: La identificación de la onda (triple, doble o simple) disminuye el tiempo de prueba a la vez que reduce los errores del técnico y el modo CW proporciona una salida continua (sin codificación).
Modos de salida admitidos: Tono de prueba (2000, 1000, 330, 270 Hz) para su uso en la identificación de la fibra con los medidores de potencia de la marca AFL, los OTDR (con acceso al extremo de la fibra) o los productos identificadores de fibra óptica (OFI) para pruebas no intrusivas a mitad de tramo.
Consulte la hoja de especificaciones para ver la lista completa de modelos y accesorios opcionales.

Fuentes de luz y kits de prueba que cumplen con el flujo EF,Kits de prueba de pérdidas ópticas SLP56D SLP5,Fuentes láser de triple longitud de onda OLS7,Fuentes de luz que cumplen con el flujo EF,OLS2 Fuente de láser doble con identificación de onda,Test Port Adapters,Fuentes de luz y medidores de potencia de la serie Contractor,FlowScout™ PON Optical Power Meter,Medidores de potencia óptica OPM5 y OPM4,Medidor de potencia óptica OPM5 con almacenamiento de datos,Adaptadores de conectores para medidores de potencia
197