The Optical Port Saver protects your OTDR ports from damage due to mating with dirty or damaged launch cables, patch cords or normal wear-and-tear.
682eccd7cdf74ff28c01d1c74c342e31
1 1. Unthread and remove connector adapter from FlexScan OTDR/OTS port. 2. Note whether FlexScan ferrule is UPC or APC (FlexScan APC ports marked with green dot). 3. Select appropriate Port Saver (see Figure 1). • Female end must match FlexScan’s ferrule type (UPC or APC). • Male end must match your launch cable connector type (UPC or APC). 4. Clean FlexScan’s ferrule end-face using a One-Click ® Cleaner, then inspect using FOCIS Flex. • If still dirty, clean with fluid and wipes, then reinspect. • If damaged, contact AFL Service to return your FlexScan for repair. 5. Inspect and clean ends of Port Saver using One-Click Cleaner & FOCIS Flex. 6. Install clean Port Saver onto FlexScan’s clean, undamaged ferrule. • Note: Rotate the connector until you feel it click into the alignment slot • Tighten the knurled knob to secure the replaceable connector. 7. Install the interchangeable connector adapter onto the Port Saver. • Note: Rotate the adapter until you feel it click into the alignment slot. • Tighten the knurled knob to secure the adapter. 8. Always clean connector end-faces before connecting a launch cable. FlexScan Port Saver Installation Instructions Test & Inspection
2 www.AFLglobal.com | 800.235.3423 © 2022, AFL, all rights reserved. FSPS-00-1ENG Revision AA 2022-02-03 Specifications are subject to change without notice . AFL NO. Port Saver Description Identifying Color Bands FlexScan Port Fiber Port 2900-58-0001MR APC female (FlexScan-facing) to APC male (fiber-facing) Green Green 2900-58-0002MR APC female (FlexScan-facing) to UPC male (fiber-facing) Green Blue 2900-58-0003MR UPC female (FlexScan-facing) to APC male (fiber-facing) Blue Green 2900-58-0004MR UPC female (FlexScan-facing) to UPC male (fiber-facing) Blue Blue 2900-58-0014MR 50 μm Multimode UPC to UPC Teal Teal Female End - FlexScan-facing Male End - Fiber-facing (Ferrule dust cap is in palace) Figure 1 Green band indicates that female end is APC Blue band indicates that male end is UPC
FEATURES:
- Prevents damage to factory installed AFL OTDR and Troubleshooter ferrules
- Allows damaged connectors to be replaced in the field
- Supports APC and UPC ferrules and connectors
- Available for single-mode and multimode OTDR ports
APPLICATIONS:
- Protect OTDR ferrule from damage due to repeated mating
- Avoid costly repairs due to damaged connectors
- Avoid downtime to return OTDR for connector replacement
- Convert APC to UPC and vice versa
Sistema de inspección de conectores de fibra óptica FOCIS Flex,FOCIS Lightning®2 Multi-Fiber Optic Connector Inspection System,Consejos para la limpieza de los conectores CCT,Palillos de limpieza del adaptador CLETOP ACT,Limpiador de conectores de fibra óptica Cletop,Limpiadores de conectores CLETOP Serie Original,Limpiador de conectores ópticos CLETOP Serie S,FCC2 Líquido limpiador y preparador de conectores de fibra mejorados Lata de 10 onzas,Líquido limpiador y preparador de conectores de fórmula mejorada FCC2,Lápiz de limpieza de fibra FCC3 Debris Destroyer,Kits de limpieza de conectores portátiles FCP,Kits de limpieza de conectores FCP1