Fiber Rings from AFL are often a necessity when testing with an OTDR. Both a launch and receive cable are required to measure complete link loss of a fiber with an OTDR. Because very long test cables are impractical to transport and use, AFL offers coiled lengths of 50 µm multimode, 62.5 µm multimode, or single-mode fiber conveniently packaged in compact rings.
81379423dda84875a040082e4bec1989,df079f1f3c88438caa68ed2fb3369f1a
©2021, AFL, all rights reserved. FR00-00-2000 Revision AB 2021-03-29 Specifications are subject to change without notice . Features • Compact, rugged, lightweight • 150, 500, and 1000 m lengths standard • Available with a variety of connector styles • Compact! Fits easily in OTDR cases or kits Applications • Use to test link loss with an OTDR • For use as OTDR launch cable • For use as OTDR receive cable • Measure insertion loss and reflectance of near- and far-end connections Fiber Rings are often a necessity when testing with an OTDR or Optical Troubleshooter. A launch cable, which connects the OTDR or Optical Troubleshooter to the link under test, reveals the insertion loss and reflectance of the near-end connection. A receive cable, which connects to the far-end of the link, reveals the insertion loss and reflectance of the far-end connection. Launch and receive test cables can range from 150 m to 1 km (or longer) in length. Because very long test cables are impractical to transport and use, AFL offers coiled lengths of 50 μm multimode, 62.5 μm multimode, or single-mode fiber packaged in compact rings. Fiber Rings of 150 m of fiber are ideal for premises fiber network test applications. Fiber Rings of 500 m and 1 km of single-mode fiber are designed for broadband, long haul fiber network test applications. 1 Test & Inspection AFLglobal.com | 800.235.3423 Accessories OTDR Fiber Rings
©2021, AFL, all rights reserved. FR00-00-2000 Revision AB 2021-03-29 Specifications are subject to change without notice . Fiber Rings Part Number Order Entry Single Fiber (SM or MM) Fiber Rings AFL NO. = FR-FFF-LLLL-CC1-CC2, where: FR = Fiber Ring (single fiber) FFF = Fiber Type SMF= Single-mode (G.652) BIF = Bend Insensitive (G.657) OM1 = 62.5 μm multimode OM2 = 50 μm multimode OM3 = 50 μm laser optimized OM4 = 50 μm laser optimized LLLL = Fiber Length (meters) 150 = 150 m (492 ft) 500 = 500 m (1640 ft) 1000 = 1000 m (3280 ft) CC1 = Connector Configuration OTDR end (see below) CC2 = Connector Configuration Network end (see below) MPO-terminated Multi-Fiber (SM or MM) Fiber Rings AFL NO. = FRM1-FF-LLLL-P-MC1-MC2 , where: FRM1 = MPO-terminated 12-fiber fiber ring FF = Fiber Type S2 = Standard single-mode (G.652) M4 = OM4 50 μm laser optimized LLLL = Fiber Length (meters) 61 = 61 m (200 ft) P = Polarity A = Type A polarity (straight through, fiber 1 to fiber 1) B = Type B polarity (fiber 1 to fiber 12) MC1, MC2 = MPO Connector (OTDR end and Network end, respectively) AF = APC, female (unpinned) AM = APC, male (pinned) UF = UPC, female (unpinned) UM = UPC, male (pinned) Supported Single Fiber Single-mode Fiber Ring Configurations CONNECTOR TYPE STANDARD SMF FIBER RINGS SPECIAL ORDER SMF FIBER RINGS a ID DESCRIPTION CC1 CC2 CC1 CC2 USC SC/UPC ASC SC/APC ULC LC/UPC ALC LC/APC UFC FC/UPC AFC FC/APC UST ST/UPC UE2 E2000/UPC Special Order a AE2 E2000/APC Special Order a OTA OptiTap APC Special Order a TRD TRIDENT APC Special Order a Supported Single Fiber Multimode Fiber Ring Configurations CONNECTOR TYPE STANDARD SMF FIBER RINGS SPECIAL ORDER SMF FIBER RINGS a ID DESCRIPTION CC1 CC2 CC1 CC2 USC SC/UPC ULC LC/UPC UFC FC/UPC UST ST/UPC UE2 E2000/UPC Special Order a 2 Test & Inspection AFLglobal.com | 800.235.3423 Accessories OTDR Fiber Rings
©2021, AFL, all rights reserved. FR00-00-2000 Revision AB 2021-03-29 Specifications are subject to change without notice . Ordering Information Standard SMF Fiber Rings DESCRIPTION AFL NO. Fiber Ring, 150 m, G.652 SMF, CC1-CC2 FR-SMF-150-CC1-CC2 Fiber Ring, 500 m, G.652 SMF, CC1-CC2 FR-SMF-500-CC1-CC2 Fiber Ring, 1000 m, G.652 SMF, CC1-CC2 FR-SMF-1000-CC1-CC2 Special Order SMF Fiber Rings a DESCRIPTION AFL NO. Fiber Ring, 150 m, G.652 SMF, CC1-CC2 FR-SMF-150-CC1-CC2 Fiber Ring, 500 m, G.652 SMF, CC1-CC2 FR-SMF-500-CC1-CC2 Fiber Ring, 1000 m, G.652 SMF, CC1-CC2 FR-SMF-1000-CC1-CC2 Fiber Ring, 150 m, G.657.A2 BIF, CC1-CC2 FR-BIF-150-CC1-CC2 Fiber Ring, 500 m, G.657.A2 BIF, CC1-CC2 FR-BIF-500-CC1-CC2 Fiber Ring, 1000 m, G.657.A2 BIF, CC1-CC2 FR-BIF-1000-CC1-CC2 Standard OM1, OM2, OM3, OM4 Multimode Fiber Rings DESCRIPTION AFL NO. Fiber Ring, 150 m, OM1 (62.5 mm) MMF, CC1-CC2 FR-OM1-150-CC1-CC2 Fiber Ring, 150 m, OM2 (50 mm) MMF, CC1-CC2 FR-OM2-150-CC1-CC2 Fiber Ring, 150 m, OM3 (50 mm laser-optimized) MMF, CC1-CC2 FR-OM3-150-CC1-CC2 Fiber Ring, 150 m, OM4 (50 mm laser-optimized) MMF, CC1-CC2 FR-OM4-150-CC1-CC2 Special Order OM1, OM2, OM3, OM4 Multimode Fiber Rings a DESCRIPTION AFL NO. Fiber Ring, 150 m, OM1 (62.5 mm) MMF, CC1-CC2 FR-OM1-150-CC1-CC2 Fiber Ring, 150 m, OM2 (50 mm) MMF, CC1-CC2 FR-OM2-150-CC1-CC2 Fiber Ring, 150 m, OM3 (50 mm laser-optimized) MMF, CC1-CC2 FR-OM3-150-CC1-CC2 Fiber Ring, 150 m, OM4 (50 mm laser-optimized) MMF, CC1-CC2 FR-OM4-150-CC1-CC2 Standard MPO-terminated Multi-fiber Single-mode and Multimode Fiber Rings b DESCRIPTION AFL NO. MPO Fiber Ring, 61 m (200 ft), G.652 SMF, Type A, APC unpinned to APC unpinned FRM1-S2-61-A-AF-AF MPO Fiber Ring, 61 m (200 ft), G.652 SMF, Type A, APC unpinned to APC pinned FRM1-S2-61-A-AF-AM MPO Fiber Ring, 61 m (200 ft), OM4 MMF, Type A, UPC unpinned to UPC unpinned FRM1-M4-61-A-UF-UF MPO Fiber Ring, 61 m (200 ft), OM4 MMF, Type A, UPC unpinned to UPC pinned FRM1-M4-61-A-UF-UM Notes: a. Contact AFL for special order fiber rings. Not all combinations of lengths and connectors are supported. b. Contact AFL for other special order configurations of MPO-terminated multi-fiber single-mode or multimode fiber rings. 3 Test & Inspection AFLglobal.com | 800.235.3423 Accessories OTDR Fiber Rings
©2021, AFL, all rights reserved. FR00-00-2000 Revision AB 2021-03-29 Specifications are subject to change without notice . How to Generate a Baseline Trace Using Fiber Rings • Use the Fiber Ring as a launch cable. Connect the Fiber Ring between your OTDR and the fiber link under test. This will allow you to measure the loss of the near-end connection. • Use the Fiber Ring as a receive cable. Connect the Fiber Ring to the far-end connector of your fiber link under test. This will allow you to measure the loss of the far-end connection. • By using Fiber Rings as both launch and receive cables, as shown in the diagram below, you can measure total insertion loss of the fiber link under test. OTDR Trace Made using Launch and Receive Cables Example OTDR Test Configuration with Launch and Receive Cables Fiber ring - launch cable Fiber ring connector OTDR port Fiber ring - receive cable OTDR Fiber link under test Near-end connection Fusion splice Far-end connection End of receive cable OTDR port Fiber ring - launch cable Near-end connection Fusion splice End of receive cable Far-end connection Fiber link under test Fiber ring - receive cable 2 2 1 1 4 4 3 3 5 5 6 6 7 7 8 8 Contact Sales@AFLglobal.com to schedule a demonstration or learn how to buy. Visit www.AFLglobal.com/Test to learn more about Fiber Rings. International Sales and Service Contact Information available at www.AFLglobal.com/Test/Contacts Recommended Products FlexScan ® FS300 (quad) and FS200 (single-mode) OTDRs • SmartAuto ® 1-button automated testing for fast results • LinkMap ® color-coded icons for easy troubleshooting • FleXpress ® mode (FS200) completes OTDR test in <5 seconds! • Integrated Source, Power Meter and VFL FlexScan ® TS100 FTTH PON Troubleshooter • Locate faults in <3 seconds with the press of a button • Displays link length, loss, ORL, and pass/fail results • Single-ended test reduces time and cost • Rugged, lightweight, hand-held for field use FS200 TS100 FS300 4 Test & Inspection AFLglobal.com | 800.235.3423 Accessories OTDR Fiber Rings
Features:
- Compact, rugged, lightweight
- 150, 500, and 1000 m lengths standard
- Available with a variety of connector styles
- Compact! Fits easily in OTDR cases or kits
Applications:
- For use as OTDR launch cable
- For use as OTDR receive cable
- Measure insertion loss and reflectance of near- and far-end connections of a fiber optic link using an OTDR
- Use to test link loss with an OTDR
OTDR Fiber Rings
Fiber Rings from AFL are often a necessity when testing with an OTDR. Fiber Rings are compact launch / receive cables designed to measure the insertion loss of the near-end and/or far-end connection of a fiber optic link using an OTDR. Both a launch and receive cable are required to measure complete link loss of a fiber with an OTDR. A launch cable, which connects the OTDR to the link under test, reveals the insertion loss and reflectance of the near-end connection. A receive cable, which connects to the far-end of the link, reveals the insertion loss and reflectance of the far-end connection. Launch and receive test cables can range from 150 m to 1 km (or longer) in length.
Because very long test cables are impractical to transport and use, AFL offers coiled lengths of 50 µm multimode, 62.5 µm multimode, or single-mode fiber conveniently packaged in compact rings.
Fiber Rings with 150 m of fiber are ideal for premises fiber network test applications. Fiber Rings with 500 m or 1 km of single-mode fiber are designed for broadband, long-haul fiber network test applications. Fiber Rings are compact and fit easily in many OTDR carry cases and test kits. Fiber Rings are available from AFL in a variety of standard angled and non-angled connector styles including SC, ST, LC, and FC.
Ordering Information
| AFL NO. (New Numbers) |
AFL NO. (Previously Used) |
FIBER TYPE |
FIBER LENGTH |
| FR-OM1-150-CC1-CC2 |
FR1-M6-150-x1-x2 |
Standard, Multimode, 62.5 µm, OM1 |
150 m (492 ft) |
| FR-OM2-150-CC1-CC2 |
FR1-M5-150-x1-x2 |
Standard, Multimode, 50 µm, OM2 |
150 m (492 ft) |
| FR-OM3-150-CC1-CC2 |
FR1-OM3-150-x1-x2 |
Laser Optimized, Multimode, 50 µm, OM3 |
150 m (492 ft) |
| FR-OM4-150-CC1-CC2 |
FR1-OM4-150-x1-x2 |
Laser Optimized, Multimode, 50 µm, OM4 |
150 m (492 ft) |
| FR-SMF-150-CC1-CC2 |
FR1-SM-150-y1-y2 |
Standard, Single-mode, G.652, SMF |
150 m (492 ft) |
| FR-SMF-500-CC1-CC2 |
FR1-SM-500-y1-y2 |
Standard, Single-mode, G.652, SMF |
500 m (1640 ft) |
| FR-SMF-1000-CC1-CC2 |
FR1-SM-1000-y1-y2 |
Standard, Single-mode, G.652, SMF |
1000 m (3280 ft) |
| FR-BIF-150-CC1-CC2 |
FR1-BIF-150-y1-y2 |
Bend Insensitive, Single-mode, G.657.A2 BIF |
150 m (492 ft) |
| FR-BIF-500-CC1-CC2 |
FR1-BIF-500-y1-y2 |
Bend Insensitive, Single-mode, G.657.A2 BIF |
500 m (1640 ft) |
| FR-BIF-1000-CC1-CC2 |
FR1-BIF-1000-y1-y2 |
Bend Insensitive, Single-mode, G.657.A2 BIF |
1000 m (3280 ft) |

FOCIS Flex Fibre Optic Connector Inspection System,FOCIS Lightning®2 Multi-Fibre Optic Connector Inspection System,CCT Connector Cleaning Tips,CLETOP ACT Adapter Cleaning Sticks,Cletop Optical Fiber Connector Cleaner,CLETOP Original Series Connector Cleaners,CLETOP S Series Optical Connector Cleaner,FCC2 Enhanced Fiber Connector Cleaner and Preparation Fluid 10 oz Can,FCC2 Enhanced Formula Connector Cleaner and Preparation Fluid,FCC3 Debris Destroyer Fiber Cleaning Pen,FCP Field Portable Connector Cleaning Kits,FCP1 Connector Cleaning Kits,One Click Cleaner Mini