When exceptional cleave quality is required for fibers up to 600 ?m, the new large diameter CT-104+ cleaver provides a variety of options depending on your needs.
d7bcc37b73c04786bb5033cda5435255
© 2021, AFL, all rights reserved. PP-4-00122, Revision 2, 9.21.2022 Specifications are subject to change without notice. AFLglobal.com | 800.235.3423 50 Fusion Splicing Cleavers When exceptional cleave quality is required for fibers up to 1,250 μm, the new large diameter CT-104+/CT-105+/CT-106+ cleaver family provides a variety of options depending on your needs. The color LCD shows cleaving progress and recommended insert size depending on fiber coating and cladding diameter. Saving and storing cleaving programs to a PC or tablet is accomplished using a USB port. The LDF cleaver’s extensive programming features allow for optimal results. Excess clamping force may deform the coating or worsen the cleave angle due to rotational stress by the clamps. Therefore, to get good cleaving quality, the clamping force should be the minimum force that does not slip while the cleaver applies fiber tension. The optimum clamping force depends on the optical fibers structure and coating material. The CT105+/ CT-106+ cleavers feature a new technology that finds the optimum clamping force automatically and accurately. Specifications PARAMETER CT-104+ CT-105+ CT-106+ Applicable optical fiber Glass optical fibers, capillary Number of fibers Single Cladding diameter 80 - 600 μm 80 - 1,250 μm Coating diameter 160 - 3,000 μm Fiber clamping Manual clamping Automatic clamping Cleaving length 5 - 40 mm Cleaving angle 1 Average 0.2° or less (Cladding diameter 125 μm) 2 Average 0.3° or less (Cladding diameter 400 μm) 2 Average 0.4° or less (Cladding diameter 600 μm) 3 Average 1.0° or less (Cladding diameter 1,000 μm) 3 Angled cleaving – – 0 - 15° (up to 800 μm cladding fiber) Blade life 4 200,000 fibers (10,000 fibers x 20 positions for 250 μm cladding fiber) Dimensions (WxDxH) 240 x 134 x 155 mm 240 x 134 x 163 mm Weight 3.4 kg 3.5 kg 3.8 kg Humidity 0 to 95% RH, non-condensing Temperature 0°C to +50°C (operation) -40°C to +80°C (storage) Number of cleaving modes Maximum 100 Cleave result 1,000 cleave data Power supply AC adapter : ADC-19A Input : AC100 to 240 V (50 to 60 Hz) (max. 20 W) Monitor TFT 4.7 inches color LCD PC interface USB 2.0 (Mini-B type) for PC communication CT-105+ CT-106+ CT-104+, CT-105+ and CT-106+ Fiber Cleavers CT-104+ Notes: 1. A new blade was used to cleave the special fibers. The average cleave angle changes depending on the environmental conditions, blade condition, operating method, and cleanliness. 2. Measured with an interferometer at room temperature. 3. Measured with the splicer, FSM-100P+. 4. The blade life changes depending on the environmental conditions, operating method, and the fiber type cleaved.
© 2021, AFL, all rights reserved. PP-4-00122, Revision 2, 9.21.2022 Specifications are subject to change without notice. AFLglobal.com | 800.235.3423 51 Fusion Splicing Cleavers Accessories DESCRIPTION AFL NO. CB-06A Replacement Blade S016078 AC adapter ADC-19A S017104 AC power cord ACC-09 S014390 Fiber Holder Inserts Master fiber holder insert kit (includes upper and lower inserts from 80 – 1750) S016098 INSERT-L-80 S016085 INSERT-L-125 S016086 INSERT-L-160 S016087 INSERT-L-250 S016088 INSERT-L-400 S016089 INSERT-L-500-750 S016090 DESCRIPTION AFL NO. Fiber Holder Inserts (continued) INSERT-L-1000-1250 S016091 INSERT-L-1500-1750 S016092 INSERT-L-2000-2250 S016093 INSERT-L-2500-3000 S016094 INSERT-U-80-400 S016079 INSERT-U-500-750 S016080 INSERT-U-1000-1250 S016081 INSERT-U-1500-1750 S016082 INSERT-U-2000-2250 S016083 INSERT-U-2500-3000 S016084 DESCRIPTION AFL NO. Height adjusting spacer (10 piece pack) SPA-CT105-30-10SET (30 μm) S016095 SPA-CT105-50-10SET (50 μm) S016096 SPA-CT105-100-10SET (100 μm) S016097 Optional Items AD-CT105-FH100 Fiber Holder Adapter S016450 TD-01 Torque Driver S016738 CT-104+, CT-105+ and CT-106+ Fiber Cleavers Angled Cleaving Angled cleaving from up to 15° is possible for fibers up to 800 μm (only for CT-106+) Automatic Clamp Function Clamp optical fiber with programmable force automatically (CT-105+ and CT-106+ only). No compressed air or torque wrenches required. clamp Backstop Improves cleave quality especially for large-diameter fibers as well as lower tension fiber cleaving and is standard on CT-105+ cleavers. backstop blade fiber backstop CT-105+ Features • 80 - 1,250 μm cladding diameter • Automatic clamping system • Up to 100 stored program modes • 200,000 cleaves per blade for 250 μm fiber • Optional adapter for use with FH-100 series fiber holders • Fiber backstop standard • Communication to a PC via USB CT-106+ Features • 80 - 1,250 μm cladding diameter • Automatic clamping system • Up to 100 stored program modes • Angled cleaving function (up to 15º on fibers up to 800 μm cladding diameter) • 200,000 cleaves per blade for 250 μm fiber • Optional adapter for use with FH-100 series fiber holders • Communication to a PC via USB CT-104+ Features • 80 - 600 μm cladding diameter • Manual clamping system • Up to 100 stored program modes • 200,000 cleaves per blade for 250 μm fiber • Optional adapter for use with FH-100 series fiber holders • Communication to a PC via USB Ordering Information DESCRIPTION AFL NO. CT-104+ Large Diameter Optical Fiber Cleaver includes: ADC-19A AC adapter, ACC-09 AC power cord, HEX-01 hex wrench, USB-01 USB Cable and M-CT104+ instruction manual S016417 CT-105+ Large Diameter Optical Fiber Cleaver includes: ADC-19A AC adapter, ACC-09 AC power cord, HEX-01 hex wrench, USB-01 USB Cable and M-CT105+ instruction manual S016076 CT-106+ Angled Large Diameter Optical Fiber Cleaver includes: ADC-19A AC adapter, ACC-09 AC power cord, HEX-01 hex wrench, USB-01 USB Cable and M-CT106+ instruction manual S016077
© 2021, AFL, all rights reserved. PP-4-00122, Revision 2, 9.21.2022 Specifications are subject to change without notice. AFLglobal.com | 800.235.3423 52 Fusion Splicing Cleavers Insert Selection Guide Upper and lower inserts can be changed up or down depending on required fiber fit into the V-groove. Inserts 500 μm and above are double-sided. Therefore, the visible label when inserted indicates the size of the insert you are using. Upper and lower inserts are necessary for both left and right side clamps. Case 1: Cleaving coating-stripped fiber Case 2: Cleaving glass rod UPPER INSERT INSERT- U-80-400 INSERT-U-500-750 1 INSERT-U-1000-1250 1 INSERT-U-1500-1750 1 INSERT-U-2000-2250 1 INSERT-U-2500-3000 1 500 750 1000 1250 1500 1750 2000 2250 2500 3000 INSERT-L-80 54-107 INSERT-L-125 84-167 INSERT-L-160 105-213 INSERT-L-250 167-333 INSERT-L-400 267-533 400-533 INSERT-L-500-750 1 500 334-667 467-667 550-667 750 634-868 717-1000 787-1000 INSERT-L-1000-1250 1 1000 884-1118 954-1188 1037-1272 1250 1120-1355 1204-1438 1287-1522 INSERT-L-1500-1750 1 1500 1370-1605 1454-1688 1537-1772 1750 1620-1855 1704-1938 1780-2015 INSERT-L-2000-2250 1 2000 1870-2105 1947-2288 2030-2265 2250 2114-2348 2197-2432 2280-2515 INSERT-L-2500-3000 1 2500 2364-2598 2447-2682 2614-2848 3000 2780-3015 2947-3182 Inserts according to both coating diameter and cladding diameter are necessary. Two insert pairs of the same size according to rod diameter are necessary. According to coating diameter According to cladding diameter L: INSERT-U-xxx-xxx R: INSERT-U-xxx-xxx L: INSERT-L-xxx-xxx R: INSERT-L-xxx-xxx L: INSERT-U-xxx-xxx R: INSERT-U-xxx-xxx L: INSERT-L-xxx-xxx According to coating diameter According to cladding diameter R: INSERT-L-xxx-xxx CT-104+, CT-105+ and CT-106+ Fiber Cleavers LOWER INSERT Note: 1. Each side of this insert is equipped with a groove that is marked with the size of the fiber diameter on the table.
Features:
- 80 - 600 μm cladding diameter
- Manual clamping system
- Up to 100 stored program modes
- 200,000 cleaves per blade for 250 μm fiber
- Optional adapter for use with FH-100 series fiber holders
- Communication to a PC via USB
ARCMaster® FSM100M and FSM100P Fusion Splicers,Fiber Processing Software FPS,AFL PowerCleave,CT105+ Fiber Cleaver,CT106+ Fiber Cleaver,CT-114 CT-115 and CT-116 Fiber Cleavers,CT52 Fiber Cleaver,CT58 Fiber Cleaver,NYFORS AutoCleaver
2107
CT104 Fiber Cleaver
Close
CT-104+ Fiber Cleaver
Features:
- 80 - 600 μm cladding diameter
- Manual clamping system
- Up to 100 stored program modes
- 200,000 cleaves per blade for 250 μm fiber
- Optional adapter for use with FH-100 series fiber holders
- Communication to a PC via USB
PRODUCT DESCRIPTION
When exceptional cleave quality is required for fibers up to 600 μm, the new large diameter CT-104+ cleaver provides a variety of options depending on your needs. The color LCD shows cleaving progress and recommended insert size depending on fiber coating and cladding diameter. Saving and storing cleaving programs to a PC or tablet is accomplished using a USB port. The LDF cleaver’s extensive programming features allow for optimal results.
Ordering Information
CT-104+ Large Diameter Optical Fiber Cleaver (AFL Part No. S016417)
Includes: ADC-19 AC adapter, ACC-09 AC power cord, HEX-01 hex wrench, USB-01 USB Cable and M-CT104+ instruction manual