AFL Duct Cables and Flame Retardant Duct Cables are designed with cable strength suitable for pulling into ducts and sub ducts. These designs are also lightweight with a low friction jacket suitable for blowing installations.
dc24722908d0463199b163190960fb47
www.AFLglobal.com 28 FEATURES AFL Duct Cables and Flame Retardant Duct Cables are designed with cable strength suitable for pulling into ducts and sub ducts. These designs are also lightweight with a low friction jacket suitable for blowing installations. DUCT CABLES • Fibre counts up to 288 • Fibre management of 6 to 12 tubes • Dry water-blocking • Metal-free therefore not subject to EMI or earth-bonding requirements • Low friction outer sheath for easy handling and installation • Lightweight and robust construction • Suitable for blowing or pulling installations • All Duct cables are tested to the Construction Products Regulation DESIGN FIBRE COUNT CROSS SECTION OD ( mm ) kg/km STRENGTH ( k N) TEMP RANGE (°C) DU-72CA6/Bk 2-72 10.5 88 2.0 -25 - 65 DU-96CA8/Bk 74-96 12 113 2.0 -25 - 65 DU-144CA12/Bk 98-144 14 139 2.0 -25 - 65 DU-288CA12/Bk 146-288 17 222 2.0 -25 - 65 DUCT CABLE CPR rated to class F CA
www.AFLglobal.com 29 DESIGN FIBRE COUNT CROSS SECTION OD ( mm ) kg/km STRENGTH ( k N) TEMP RANGE (°C) DU-72LSA6/Bk 2-72 10.5 118 2.0 -25 - 65 DU-96LSA8/Bk 74-96 12.5 157 2.0 -25 - 65 DU-144LSA12/Bk 98-144 14 176 2.0 -25 - 65 DESIGN FIBRE COUNT CROSS SECTION OD ( mm ) kg/km STRENGTH ( k N) TEMP RANGE (°C) DU-72LSG6/Bk 2-72 10.5 117 2.7 -25 - 65 DU-96LSG8/Bk 74-96 12.5 156 2.7 -25 - 65 DU-144LSG12/Bk 98-144 14 188 2.7 -25 - 65 DESIGN FIBRE COUNT CROSS SECTION OD ( mm ) kg/km STRENGTH (k N) TEMP RANGE (°C) DU-72CG6/Bk 2-72 10.5 91 2.7 -25 - 65 DU-96CG8/Bk 74-96 12 123 2.7 -25 - 65 DU-144CG12/Bk 98-144 14 170 2.7 -25 - 65 CPR rated to class F CA CPR rated to class E CA CPR rated to class E CA LSZH DUCT CABLE GLASS REINFORCED LSZH DUCT CABLE DUCT CABLES GLASS REINFORCED DUCT CABLE Single-mode, multi-mode and non-zero dispersion-shifted fibre types are available on request
Features
- Fibre counts up to 288
- Fibre management of 6 to 12 tubes
- Dry water-blocking
- Metal-free therefore not subject to EMI or earth-bonding requirements
- Low friction outer sheath for easy handling and installation
- Lightweight and robust construction
- Suitable for blowing or pulling installations
- All Duct cables are tested to the Construction Products Regulation
Applications
- Distribution
- Underground Duct
- Long Haul Networking
- Building Interconnections (Campus LAN)
- Trunking Lines Direct to Telecommunications Closet
- Local Loop
AFL Duct Cables and Flame Retardant Duct Cables are designed with cable strength suitable for pulling into ducts and sub ducts. These designs are also lightweight with a low friction jacket suitable for blowing installations.
Furcation Tubing Fiber Optic Cable | AFL,Simplex Cable Fiber Optic Cable – Specs & Compatibility | AFL,Zipcord DualLink and MicroDual Cable | AFL,GelFree Riser Nonarmored Loose Tube Lv Series GelFree Sj | AFL,Indooroutdoor Armored Tight Buffered Circular Premise Cable – Indoor/Outdoor Armored Tight Buffered Circular Premise Cable | AFL,Indoor/Outdoor Breakout Cable – IndoorOutdoor Breakout Cable | AFL,Indoor/Outdoor Multi Unit Plenum Tight Buffered Cable – IndoorOutdoor Multi | AFL,Indoor/Outdoor Multi Unit Riser Tight Buffered Cable – IndoorOutdoor Multi | AFL,Indoor/Outdoor Plenum Distribution Cable – IndoorOutdoor Plenum Distribution | AFL,IndoorOutdoor Riser Sub unitized MicroCore Cable | AFL,Indooroutdoor Riser Sub Unitized MicroCore Cable with SpiderWeb Ribbon Technology – Indoor/Outdoor Riser Sub Unitized MicroCore Cable with SpiderWeb Ribbon Technology | AFL,Indoor/Outdoor Riser Tight Buffered Cable – IndoorOutdoor Riser Tight | AFL,Low Smoke Zero Halogen Indooroutdoor Breakout Cable – Low Smoke Zero Halogen Indoor/Outdoor Breakout Cable – Low Smoke Zero | AFL,Lq Series Plenum Rated Indooroutdoor Loose Tube – Lq Series Plenum Rated Indoor/Outdoor Loose Tube – LQ Series Plenum rated | AFL