Pour répondre aux nouvelles exigences des sources lumineuses multimodes de la norme TIA/EIA-568-B, AFL propose des mandrins pour les cavaliers de test de 50 et 62,5 µm avec des gaines de 3 mm. Les deux mandrins sont dotés de rainures pour garantir que les cavaliers sont enveloppés exactement cinq fois (comme spécifié par TIA/EIA-568-B) et peuvent être facilement fixés aux cavaliers de test en quelques secondes sans outils ni ruban adhésif.
3bae62a85569400cb1103acf7357eca6
1 Test & Inspection AFLglobal.com | 800.235.3423 Accessories Mandrels ©2020, AFL, all rights reserved. 5400-00-2001 Revision AD 2020-11-04 Specifications are subject to change without notice . For use with 62.5 and 50 μm Multimode Test J umpers with 3 mm J ackets Features • Allows existing 850/1300 nm LED light sources to test 50 and 62.5 μm links • Attaches to 3 mm jumpers in seconds, without tools or tape • May be reused indefinitely Applications • Required by TIA/EIA-568-B to measure attenuation on multimode fiber links • Certification of multimode links for Gigabit and 10 Gigabit Ethernet 62.5 μm 50 μm TIA/EIA-568-B specifies that attenuation (insertion loss) measurements of multimode fiber links, for all applications, must be made using an overfilled light source, such as an LED, with a mandrel-wrap mode filter on the transmit jumper. A key advantage of this specification is that it allows the use of existing overfilled LED light sources to certify both 50 and 62.5 μm fiber links for current and planned high bit rate applications including Gigabit Ethernet and 10 Gigabit Ethernet. To meet the new multimode light source requirements in TIA/EIA-568-B, we offer mandrels for 50 and 62.5 μm test jumpers with 3 mm jackets. Both mandrels have grooves to ensure that jumpers are wrapped exactly five times (as specified by TIA/EIA-568-B) and can be easily attached to test jumpers in seconds without tools or tape. Ordering Information DESCRIPTION AFL NO. Kit with two mandrels: 62.5 and 50 μm fiber 5400-00-0900 Mandrel, 62.5 μm fiber 5400-00-0201 Mandrel, 50 μm fiber 5400-00-0202
2 Test & Inspection AFLglobal.com | 800.235.3423 Accessories Mandrels Transmit jumper Mandrel wrap ST adapter cap Light Source Power Meter 0 dB Transmit jumper Mandrel wrap ST adapter cap 0 dB 0 dB Transmit jumper Mandrel 5 wraps Transmit jumper Mandrel 5 wraps 5 wraps Receive jumper ST adapter Cap ST adapter Transmit jumper Mandrel wrap 0.4 dB Receive jumper Receive jumper ST adapter Cap ST adapter Transmit jumper Mandrel wrap 0.4 dB 0.4 dB Link under test Transmit jumper Mandrel wrap Receive Jumper ST adapter cap ST ST 3.2 dB 3.2 dB 3.2 dB ©2020, AFL, all rights reserved. 5400-00-2001 Revision AD 2020-11-04 Specifications are subject to change without notice . For use with 62.5 and 50 μm Multimode Test Jumpers with 3 mm Jackets 1 Attach Mandrel Wrap the transmit jumper five times around the mandrel and attach it to the output port of the OLS 1 (LED source). Attach the ST adapter cap to the input port of the OPM 5 (optical power meter). Turn both units on and set wavelength to 850 nm. 2 Set Reference (One Jumper Method) Connect the output of the OLS 1 directly to the input (ST adapter cap) of the OPM 5. Then press and hold the Set Ref (set reference) key until the word “HELD” appears. When you release the Set Ref key the OPM 5 should display “0 dB” (+/- 0.05 dB) indicating that the power measured at output of the transmit jumper has been recorded as the reference level for your insertion loss measurements. 3 Check Jumpers Disconnect the transmit jumper from the OPM 5 (be sure NOT to remove the end of the jumper connected to the OLS 1). Attach the receive jumper to the OPM 5. Mate the free ends of the transmit and receive jumpers using the ST-ST adapter. Verify that the insertion loss of this mated connector pair is well under 0.75 dB, the maximum allowed by the TIA. Noyes recommends that the loss of your mated test jumpers be 0.4 dB. If not, clean both jumpers and repeat steps 2 and 3. 4 Test Links Connect the OLS 1 and OPM 5 to opposite ends of the first link to be tested. Store the insertion loss measured by the OPM 5 by pressing the STORE key. You can repeat Step 4 to measure the insertion loss of each multimode link at 850 nm. Then, if required, set both units to 1300 nm and repeat Steps 2 thru 4 to measure the insertion loss of your multimode links at 1300 nm. The OPM 5 can store insertion loss results at 850 and 1300 nm for up to 500 fibers. Example Procedure The following procedure illustrates how to make attenuation measurements of mul timode fiber links using an LED light source, optical power meter, and mandrels. The procedure assumes that the link under test is terminated by ST connectors at both ends. However, it can easily be adapted for links terminated by other connector types simply by using the appropriate test jumpers and adapter caps. For this procedure you will need the following: • (1) MM (LED) light source • (1) optical power meter • (1) ST adapter cap • (1) 62.5 or 50 μm mandrel • (2) test jumpers with 3 mm jackets and the same fiber type (62.5 or 50 μm) as the multimode link under test • (1) ST-ST (mating) adapter Contact Sales@AFLglobal.com to schedule a demonstration or learn how to buy. Visit www.AFLglobal.com/Test to learn more about mandrels. International Sales and Service Contact Information available at www.AFLglobal.com/Test/Contacts
Caractéristiques :
- Les mandrins sont dotés de rainures pour garantir que les cavaliers sont enroulés exactement cinq fois (conformément à la norme TIA/EIA-568-B).
- Se fixe aux cavaliers de 3 mm en quelques secondes, sans outil ni ruban adhésif.
- Permet aux sources lumineuses LED 850/1300 nm existantes de tester les liaisons de 50 et 62,5 µm.
- Peut être réutilisé indéfiniment
Les applications:
- Requis par TIA/EIA-568-B pour mesurer l'atténuation sur les liaisons en fibre multimode
- Permet de certifier les liaisons multimodes pour l'Ethernet Gigabit et 10 Gigabit.
- Permet aux sources lumineuses LED 850/1300nm existantes de tester les liaisons 50 et 62.5µm
- Peut être réutilisé indéfiniment
Mandrins à utiliser avec des cavaliers de test multimode de 50 et 62,5 µm avec des gaines de 3 mm
La norme TIA/EIA-568-B spécifie que les mesures d'atténuation (perte d'insertion) des liaisons en fibre multimode pour toutes les applications doivent être effectuées à l'aide d'une source lumineuse surchargée, telle qu'une LED, avec un filtre de mode à mandrin sur le cavalier d'émission. L'un des principaux avantages de cette spécification est qu'elle permet d'utiliser les sources lumineuses à DEL surchargées existantes pour certifier les liaisons par fibre de 50 et 62,5 µm pour les applications à haut débit actuelles et prévues, notamment Gigabit Ethernet et 10 Gigabit Ethernet.
Pour répondre aux nouvelles exigences en matière de sources lumineuses multimodes de la norme TIA/EIA-568-B, nous proposons des mandrins pour des cavaliers de test de 50 et 62,5 µm avec des gaines de 3 mm. Les deux mandrins sont dotés de rainures pour garantir que les cavaliers sont enveloppés exactement cinq fois (comme spécifié par TIA/EIA-568-B) et peuvent être facilement fixés aux cavaliers de test en quelques secondes sans outils ni ruban adhésif.
Caractéristiques
- Requis par TIA/EIA-568-B pour mesurer l'atténuation sur les liaisons en fibre multimode
- Permet la certification des liaisons multimodes pour l'Ethernet Gigabit et 10 Gigabit
- Permet aux sources lumineuses LED 850/1300nm existantes de tester les liaisons de 50 et 62,5µ
m - Se fixe aux cavaliers de 3 mm en quelques secondes, sans outil ni ruban adhésif.
Informations pour la commande
| | DESCRIPTION N° AFL | | Kit avec deux mandrins : 62,5 et 50 µm fibre | |
5400-00-0900PZ | | Mandrin, 62,5 µm fibre
| 5400-00-0201PZ | |
Mandrin, 50 µ
m fibre
5400-00-0202PZ
| 
Système d'inspection des connecteurs de fibres optiques FOCIS Flex,FOCIS Lightning®2 Multi-Fiber Optic Connector Inspection System,Conseils pour le nettoyage des connecteurs CCT,Bâtonnets de nettoyage CLETOP ACT Adapter,Nettoyant pour connecteurs de fibres optiques Cletop,Nettoyeurs de connecteurs CLETOP Original Series,Nettoyant pour connecteurs optiques CLETOP Série S,FCC2 Fluide de nettoyage et de préparation des connecteurs de fibres améliorés Boîte de 10 oz,Fluide de préparation et de nettoyage des connecteurs à formule améliorée FCC2,Stylo nettoyeur de fibres FCC3 Debris Destroyer,Kits de nettoyage de connecteurs portables de terrain FCP,Kits de nettoyage de connecteurs FCP1
614