SWGX Swage Cross four-tap connector cross connects four cable or rod together. SWGXH Swage Thru-Hole Cross connector has a thru-hole run and two taps. SWGXOSS Swage Offset Split Cross connector is used to connect a cable run to another cable. It features two sliding channels for ease of installation.
eecceab84d074950b1dd0abaf536634c
www.AFLglobal.com or 800-890-8878 26 Swage Grounding Accessories © 2016, AFL, all rights reserved. PP-3-00738, Revision 1, 3.16.18 Specifications are subject to change without notice. GROUNDING Material Copper Alloy Notes • For tin plating, add "-SN" to end of catalog number. EX: SWGX2025-SN. • For detailed conductor range information, please see page 33 (L11557). TYPE SWGX Swage Cross A Swage type four-tap connector cross connects four cable or rod together. AFL NO. COPPER CABLE (AWG OR KCMIL) DIMENSIONS IN INCHES DIE SIZE TAP 1 TAP 2 OD A SWGX2013 1/0-2/0 1/0-2/0 1.25 4.34 45TD20 SWGX2017 3/0 3/0 1.25 4.34 45TD20 SWGX2021 4/0 4/0 1.25 4.34 45TD20 SWGX2025-2013 250 1/0-2/0 1.25 4.34 45TD20 SWGX2025-2021 250 4/0 1.25 4.34 45TD20 SWGX2025 250 250 1.25 4.34 45TD20 SWGX2025-2035 250 350 1.25 4.34 45TD20 SWGX2413-2450 1/0-2/0 500 1.50 4.60 45TD24 SWGX2421 4/0 4/0 1.50 4.60 45TD24 SWGX2430-2425 300 250 1.50 4.60 45TD24 SWGX2450-2425 500 250 1.50 4.60 45TD24 SWGX2450 500 500 1.50 4.60 45TD24 A TAP 2 TAP 1 TAP 1 TAP 2 A Ø OD SW2TC XX SWGX Tap 1 Cable Code for Largest Conductor YYY XX Die Code ZZZ Ordering Information Part Family (Leave blank if same as Run) Tap 2 Cable Code Die Code comes from maximum connector OD from Table at right. • EX: Tin-plated cross for 500MCM Cu to 250MCM Cu is SWGX2450-2425-SN • EX: Cross for 250MCM Cu to 250MCM is SWGX2025 Die Code
Features:
- Copper Alloy
- Swage compression fitting for grounding applications
- Installs faster and more efficiently with lower installation costs over the welding process
Applications:
- Substation
- Copper Alloy Grounding Accessories
SWGX Swage Cross four-tap connector cross connects four cable or rod together. SWGXH Swage Thru-Hole Cross connector has a thru-hole run and two taps. SWGXOSS Swage Offset Split Cross connector is used to connect a cable run to another cable. It features two sliding channels for ease of installation.
230 kV Aluminum Compression Couplers,230 kV Aluminum Compression Tee Connectors,230 kV Aluminum Compression Tee Terminal Connectors,230 kV Aluminum Compression Terminal Connectors,230 kV Aluminum Welded Bus Pipe Couplers,230 kV Aluminum Welded Bus Pipe Elbows,230 kV Aluminum Welded Bus Pipe Supports,230 kV Aluminum Welded Bus Pipe Tee and Vee Connectors,230 kV Aluminum Welded Bus Pipe Terminal Connectors,230 kV Aluminum Welded Bus Pipe to Cable Couplers,230 kV Aluminum Welded Bus Pipe to Cable Tee,230 kV Aluminum Welded Cable Terminal,230 kV Aluminum Welded End Plugs,230 kV Aluminum Welded Grounding Rod,230 kV Aluminum Welded Pipe Taps
2144