The HiTemp 15 degree compression terminal is specially designed and engineered to provide improved heat dissipation, AFL's HiTemp Compression Accessories are designed to operate 25-30% cooler than the conductor, extending its life. The HiTemp product line is rated for operation up to 250°C.
1fbcd62ab59f460cb0daead450ca6727
7 15° and Straight Terminals for ACCC T PRESS TO END 10030AH S A R T AFL Catalog Number Configuration for 15 ° and Straight Terminals B11403 AFL Code Notes 1. For 345 kV and above, add suffix "EHV" to AFL No. For example, B11403-AZEHV-ACCC. 2. For more information, contact AFL at 1.800.866.7385. 3. Additional angles available upon request. 15° Blank = voltage <345 kV EHV = voltage ≥ 345 kV EHV AFL NO. ACCC CONDUCTOR DIAMETER CORE DIAMETER WEIGHT CORE RATED STRENGTH COND. RATED STRENGTH TERMINAL 15 ° STRAIGHT TERMINAL SIZE (KCMIL) (MM²) (IN) (MM) (IN) (MM) (LB/ KFT) (KG/ KM) (LBF) (KN) (LBF) (KN) B11403-K-ACCC B11938-K-ACCC HELSINKI 297 150.6 0.616 15.65 0.235 5.97 317 471 13,600 60.4 15,500 68.9 B11403-G-ACCC B11938-G-ACCC JAIPUR 309 156.7 0.650 16.50 0.305 7.75 349 519 22,900 101.7 24,900 110.8 B11403-BB-ACCC B11938-BB-ACCC ZADAR 356 180.3 0.673 17.09 0.280 7.11 386 574 19,300 85.7 21,600 96.1 B11403-BC-ACCC B11938-BC-ACCC ROVINJ 378 191.6 0.673 17.10 0.235 5.97 392 583 13,600 60.4 16,000 71.2 B11403-L-ACCC B11938-L-ACCC COPENHAGEN 434 219.9 0.720 18.29 0.235 5.97 444 661 13,600 60.4 16,400 72.8 B11403-M-ACCC B11938-M-ACCC REYKJAVIK 440 223.1 0.741 18.82 0.280 7.11 466 694 19,300 85.7 22,100 98.3 B11403-BD-ACCC B11938-BD-ACCC GDANSK 491 248.7 0.756 19.20 0.235 5.97 499 743 13,600 60.4 16,700 74.3 B11403-N-ACCC B11938-N-ACCC GLASGOW 467 236.7 0.769 19.53 0.305 7.75 492 732 22,900 101.7 25,900 115.0 B11403-P-ACCC B11938-P-ACCC CASABLANCA 540 273.6 0.807 20.50 0.280 7.11 561 834 19,300 85.7 22,700 101.1 B11403-R-ACCC B11938-R-ACCC MONTE CARLO 451 228.5 0.818 20.78 0.415 10.54 537 799 42,300 188.3 45,200 201.2 B11403-S-ACCC B11938-S-ACCC ULS MONTE CARLO 451 228.5 0.819 20.79 0.415 10.54 537 799 50,700 225.6 53,600 238.6 B11403-B-ACCC B11938-B-ACCC LISBON 623 315.5 0.858 21.79 0.280 7.11 637 948 19,300 85.7 23,300 103.5 B11403-F-ACCC B11938-F-ACCC OSLO 619 313.8 0.882 22.40 0.345 8.76 659 981 29,300 130.2 33,200 147.8 B11403-T-ACCC B11938-T-ACCC AMSTERDAM 725 367.4 0.927 23.55 0.305 7.75 740 1101 22,900 101.7 27,500 122.4 B11403-X-ACCC B11938-X-ACCC ULS 25mm 753 381.8 0.984 25.00 0.415 10.54 817 1216 50,700 225.6 55,600 247.2 B11403-W-ACCC B11938-W-ACCC BRUSSELS 832 421.4 0.990 25.15 0.320 8.13 850 1265 25,200 112.0 30,500 135.7 B11403-Y-ACCC B11938-Y-ACCC ULS LEIPZIG 802 406.4 0.990 25.15 0.375 9.53 842 1253 41,300 183.5 46,600 207.3 B11403-BE-ACCC B11938-BE-ACCC STOCKHOLM 2L 914 463.3 1.039 26.39 0.345 8.76 937 1395 29,300 130.2 35,100 156.2 B11403-BE-ACCC B11938-BE-ACCC STOCKHOLM 3L 895 453.7 1.039 26.39 0.345 8.76 919 1368 29,300 130.2 35,000 155.7 B11403-Z-ACCC B11938-Z-ACCC WARSAW 1002 507.5 1.091 27.71 0.345 8.76 1021 1520 29,300 130.2 35,700 158.7 B11403-A-ACCC B11938-A-ACCC DUBLIN 1035 524.5 1.108 28.14 0.375 9.53 1064 1583 34,600 153.8 41,200 183.3 B11403-AB-ACCC B11938-AB-ACCC HAMBURG 1078 546.4 1.127 28.63 0.345 8.76 1093 1627 29,300 130.2 36,200 160.9 B11403-AC-ACCC B11938-AC-ACCC KOLKATA 1073 543.5 1.127 28.63 0.375 9.53 1104 1643 34,600 153.8 41,400 184.0 B11403-AD-ACCC B11938-AD-ACCC ULS MAHAKAM 1075 544.9 1.142 29.01 0.415 10.54 1127 1677 50,700 225.6 57,600 256.3 B11403-AE-ACCC B11938-AE-ACCC MILAN 1120 567.7 1.146 29.11 0.345 8.76 1133 1686 29,300 130.2 36,400 162.1 B11403-AF-ACCC B11938-AF-ACCC ROME 1169 592.5 1.177 29.90 0.375 9.53 1192 1774 34,600 153.8 42,100 187.1 B11403-AG-ACCC B11938-AG-ACCC VIENNA 1242 629.2 1.198 30.43 0.345 8.76 1245 1853 29,300 130.2 37,200 165.5 B11403-AH-ACCC B11938-AH-ACCC BUDAPEST 1319 668.3 1.240 31.50 0.375 9.53 1333 1984 34,600 153.8 43,000 191.4 B11403-AK-ACCC B11938-AK-ACCC PRAGUE 1363 690.7 1.251 31.78 0.345 8.76 1364 2031 29,300 130.2 38,000 169.0 B11403-AL-ACCC B11938-AL-ACCC ULS PRAGUE 1363 690.7 1.251 31.78 0.345 8.76 1364 2031 34,900 155.1 43,800 194.8 B11403-AM-ACCC B11938-AM-ACCC MUMBAI 1353 685.4 1.251 31.78 0.375 9.53 1367 2035 34,600 153.8 43,200 192.0 B11403-H-ACCC B11938-H-ACCC MUNICH 1447 733.1 1.293 32.84 0.375 9.53 1458 2170 34,600 153.8 43,800 195.0 B11403-AN-ACCC B11938-AN-ACCC LONDON 1498 759.0 1.315 33.40 0.385 9.78 1511 2248 36,400 162.1 46,000 204.8 ACCC
8 15° and Straight Terminals for ACCC (cont.) AFL NO. ACCC CONDUCTOR DIAMETER CORE DIAMETER WEIGHT CORE RATED STRENGTH COND. RATED STRENGTH TERMINAL 15 ° STRAIGHT TERMINAL SIZE (KCMIL) (MM²) (IN) (MM) (IN) (MM) (LB/ KFT) (KG/ KM) (LBF) (KN) (LBF) (KN) B11403-AP-ACCC B11938-AP-ACCC PARIS 1606 813.7 1.345 34.16 0.345 8.76 1590 2366 29,300 130.2 39,600 175.9 B11403-AW-ACCC B11938-AW-ACCC BORDEAUX 1738 880.8 1.408 35.76 0.415 10.54 1859 2766 42,300 188.3 53,500 237.9 B11403-AS-ACCC B11938-AS-ACCC ANTWERP 1865 944.8 1.451 36.86 0.385 9.78 1855 2760 36,400 162.1 48,400 215.2 B11403-AT-ACCC B11938-AT-ACCC ULS ANTWERP 1865 944.8 1.451 36.86 0.385 9.78 1855 2760 43,500 193.5 55,600 247.3 B11403-E-ACCC B11938-E-ACCC BERLIN (MADRID-ICE) 1986 1006.5 1.504 38.20 0.415 10.54 1982 2949 42,300 188.3 55,100 245.0 B11403-AX-ACCC B11938-AX-ACCC MADRID 1999 1013.0 1.504 38.20 0.385 9.78 1981 2948 36,400 162.1 49,200 219.1 B11403-AZ-ACCC B11938-AZ-ACCC ATHENS 2782 1409.6 1.762 44.75 0.415 10.54 2732 4066 42,300 188.3 60,200 267.6
Specially tempered aluminum
Standard AH and SH dies
Comealongs and HiTemp Comealongs for ACSR AAC AAAC ACAR ACSS and ACSSTW Conductors,AFL Filler Compound,Alnox Electrical Joint Compound,Alnox UG Electrical Joint Compound,HiTemp® AFL Filler Compound (AFCHT™),HiTemp® AFL Universal Compound (HiTUC),No. 2 Electrical Joint Compound,HiTemp® Compression Dead Ends for ACSS Conductors,HiTemp® Compression Dead Ends for ACSS/TW Conductors,HiTemp® Compression Joints for ACSS Conductors,HiTemp® Compression Joints for ACSS/TW Conductors,HiTemp® Compression Jumper for ACSS Conductors,HiTemp® Compression Jumper for ACSS/TW Conductors,HiTemp® Compression Repair Sleeve for ACSS Conductors,HiTemp® Compression Repair Sleeve for ACSS/TW Conductors
1746