Substation tee connector is designed for limited space application as found in substations. Run and tap lengths are shorter than conventional tee connectors which saves space and minimizes birdcaging problems. Tee connector is installed with standard ACA hex dies.
196f91a90f4a47fa8d250f5f20d30ec4
454 AFLglobal.com 1 (800) 890-8878 © 2010, AFL, all rights reserved. PP-3-00168, Revision 4, 11.21.2024 Specifications are subject to change without notice. 454 230 kV Aluminum Compression Type 2800 Series Substation tee connector is designed for limited space application as found in substations. Run length is shorter than conventional tee taps which saves space and allows faster installation. Tee tap is installed with standard AFL hex dies. Ordering Information Catalog Number Conductor Range Pad Size Die Size Alternate Catalog Number Alternate Pad Size Dimensions (inches) Nominal Weight (lbs) Diameter Range (inches) AAC ACSR MCM A T 2876.1 .609 - .743 300 - 397.5 266.8(18/1) - 336.4(30/7) B 76AH 2876.1D D 8.5 0.5 0.73 2820.1 .718 - .840 397.5 - 500 336.4(26/7) - 477(18/1) B 20AH 2820.1D D 8.5 0.5 0.91 2824.1 .780 - .933 477 - 650 397.5(26/7) - 556.5(26/7) B 24AH 2824.1D D 8.5 0.5 1.2 2827.1 .932 - 1.020 700 - 750 556.5(30/7) - 666.6(24/7) D 27AH 2827.1B B 10 0.62 2.1 2830.1 1.021 - 1.196 795 - 1033.5 715.5(24/7) - 954(54/7) D 30AH 2830.1B B 10 0.62 2.6 2834.1 1.140 - 1.319 1000 - 1300 795(30/19) - 1192.5(45/7) D 34AH 2834.1E E 11.5 0.62 3.4 2836.1 1.320 - 1.417 1351.5 - 1510.5 1192.5(54/19) - 1351.5(45/7) D 36AH 2836.1E E 11.5 0.62 3.7 2838.1 1.412 - 1.500 1500 - 1590 1351.5(54/19) - 1510.5(45/7) D 38AH 2838.1E E 12 0.62 4.3 2840.1 1.496 - 1.557 1750 1510.5(54/19) - 1590(54/19) D 40AH 2840.1E E 12.5 0.62 4.8 2842.1 1.550 - 1.625 - 1780(84/19) E 42AH 2842.1D D 14 0.75 6.4 2844.1 1.626 - 1.842 2000 - 2500 2034(72/7) - 2312(76/19) E 44AH 2844.1D D 14 0.75 6.3 2848.1 1.843 - 1.996 2750 2515(76/19) E 48AH 2848.1D D 16 0.75 7.1 PAD D A 1 3 / 4 B T PAD E 3 1 3 / 4 5 / 8 5 / 8 1 3 / 4 ∅ 9 / 16 ∅ 9 / 16 4 1 / 2 4 1 1 / 8 1 3 / 4 1 3 / 4 PAD B 1 3 / 4 3 1 / 2 3 1 / 2 ∅ 9 / 16
459 AFLglobal.com 1 ( 8 00) 8 66-7385 © 2004, AFL, all rights reserved. P P - 3-00909, Revision 7 , 4.27.2026 Specications are subject to change without notice. 459 Standard C ompression – ACSR Tee Connector—5500 Series for ACSR Conductors, Open Run The 5500 Series Tee Connector is a permanent drop designed for ACSR conductors. The tee connector is fabricated from AFL seamless drawn aluminum. The run portion incorporates an improved design of interlocking extrusions, providing a permanent grip on the conductor when compressed. The branch portion of the tee connector is designed for limited tension use, maintaining a minimum of 40% of the ASTM rated strength of the conductor on which it is being used. For die size sections 30AH and above, the end tapers of the compression portions of all compression accessories are supplied with a high voltage finish. Ordering Instructions Step 1: Determine Run Catalog Number Determine the run catalog number based on the conductor being used. Step 2: Determine Branch Catalog Number Determine the branch catalog number based on the conductor being used. Step 3: Assemble Catalog Number Example: For 795 Drake Conductor in both Run and Branch, the complete catalog number is: 5530.3 – 30.116 Run Catalog Number + Notes: 1. AFL Filler Compound (AFC) requirements are on page 115. 2. Installation Instructions for Open Run Tee Connectors are on page 144. Branch Catalog Number
460 AFLglobal.com 1 ( 8 00) 8 66-7385 © 2004, AFL, all rights reserved. P P - 3-00909, Revision 7 , 4.27.2026 Specications are subject to change without notice. 460 Standard C ompression – ACSR Tee Connector—5500 Series for ACSR Conductors, Open Run (cont.) CONDUCTOR CATALOG NUMBER DIE SIZE WEIGHT DIMENSIONS CODE WORD SIZE STRANDING DIA. RUN CONDUCTOR BRANCH CONDUC - TOR ALUMINUM HEX DIE RUN BRANCH A B KCMIL AL/ST IN LBS KG LBS KG IN MM IN MM Raven 1/0 6/1 0.398 5574 74.438 74AH 0.2 0.10 0.2 0.09 7.6 192 5.5 140 Quail 2/0 6/1 0.447 5574 74.438 74AH 0.2 0.10 0.2 0.09 7.6 192 5.5 140 Pigeon 3/0 6/1 0.502 5575 75.547 75AH 0.4 0.18 0.3 0.14 8.6 217 6.0 152 Penguin 4/0 6/1 0.563 5575 75.609 75AH 0.4 0.18 0.3 0.14 8.6 217 6.0 152 Waxwing 266.8 18/1 0.609 5576 76.656 76AH 0.7 0.30 0.5 0.23 10.0 254 6.5 165 Owl 266.8 6/7 0.633 5576 76.688 76AH 0.7 0.30 0.5 0.23 10.0 254 6.5 165 Partridge 266.8 26/7 0.642 5576 76.688 76AH 0.7 0.30 0.5 0.23 10.0 254 6.5 165 Ostrich 300.0 26/7 0.680 5576 76.719 76AH 0.7 0.30 0.5 0.23 10.0 254 6.5 165 Merlin 336.4 18/1 0.684 5576 76.719 76AH 0.7 0.30 0.5 0.23 10.0 254 6.5 165 Linnet 336.4 26/7 0.720 5576 76.781 76AH 0.7 0.30 0.5 0.23 10.0 254 6.5 165 Chickadee 397.5 18/1 0.743 5576 76.781 76AH 0.7 0.30 0.5 0.23 10.0 254 6.5 165 Linnet 336.4 26/7 0.720 5520.3 20.781 20AH 1.0 0.45 0.6 0.27 14.5 368 7.6 194 Oriole 336.4 30/7 0.741 5520.3 20.781 20AH 1.0 0.45 0.6 0.27 14.5 368 7.6 194 Chickadee 397.5 18/1 0.743 5520.3 20.781 20AH 1.0 0.45 0.6 0.27 14.5 368 7.6 194 Brant 397.5 24/7 0.772 5520.3 20.812 20AH 1.0 0.45 0.6 0.27 14.5 368 7.6 194 Ibis 397.5 26/7 0.783 5520.3 20.844 20AH 1.0 0.45 0.6 0.27 14.5 368 7.6 194 Lark 397.5 30/7 0.806 5520.3 20.844 20AH 1.0 0.45 0.6 0.27 14.5 368 7.6 194 Pelican 477.0 18/1 0.814 5524.3 24.875 24AH 1.7 0.77 0.8 0.36 15.5 394 8.3 210 Flicker 477.0 24/7 0.846 5524.3 24.938 24AH 1.7 0.77 0.8 0.36 15.5 394 8.3 210 Hawk 477.0 26/7 0.858 5524.3 24.938 24AH 1.7 0.77 0.8 0.36 15.5 394 8.3 210 Hen 477.0 30/7 0.883 5524.3 24.938 24AH 1.7 0.77 0.8 0.36 15.5 394 8.3 210 Osprey 556.5 18/1 0.879 5524.3 24.938 24AH 1.7 0.77 0.8 0.36 15.5 394 8.3 210 Parakeet 556.5 24/7 0.914 5524.3 24.969 24AH 1.7 0.77 0.8 0.36 15.5 394 8.3 210 Dove 556.5 26/7 0.927 5524.3 24.969 24AH 1.7 0.77 0.8 0.36 15.5 394 8.3 210 Eagle 556.5 30/7 0.953 5527.3 27.100 27AH 2.7 1.22 1.3 0.59 18.3 464 8.8 225 Peacock 605.0 24/7 0.953 5527.3 27.100 27AH 2.7 1.22 1.3 0.59 18.3 464 8.8 225 Squab 605.0 26/7 0.966 5527.3 27.100 27AH 2.7 1.22 1.3 0.59 18.3 464 8.8 225 Teal 605.0 30/19 0.994 5527.3 27.106 27AH 2.7 1.22 1.3 0.59 18.3 464 8.8 225 Swift 636.0 36/1 0.930 5527.3 27.100 27AH 2.7 1.22 1.3 0.59 18.3 464 8.8 225 Kingbird 636.0 18/1 0.940 5527.3 27.100 27AH 2.7 1.22 1.3 0.59 18.3 464 8.8 225 Rook 636.0 24/7 0.977 5527.3 27.106 27AH 2.7 1.22 1.3 0.59 18.3 464 8.8 225 Grosbeak 636.0 26/7 0.990 5527.3 27.106 27AH 2.7 1.22 1.3 0.59 18.3 464 8.8 225 Egret 636.0 30/19 1.019 5527.3 27.106 27AH 2.7 1.22 1.3 0.59 18.3 464 8.8 225 Flamingo 666.6 24/7 1.000 5527.3 27.106 27AH 2.7 1.22 1.3 0.59 18.3 464 8.8 225 Stilt 715.5 24/7 1.036 5530.3 30.109 30AH 3.3 1.50 1.7 0.77 19.1 486 9.4 240 Starling 715.5 26/7 1.051 5530.3 30.109 30AH 3.3 1.50 1.7 0.77 19.1 486 9.4 240 Redwing 715.5 30/19 1.081 5530.3 30.116 30AH 3.3 1.50 1.7 0.77 19.1 486 9.4 240 Coot 795.0 36/1 1.040 5530.3 30.109 30AH 3.3 1.50 1.7 0.77 19.1 486 9.4 240
461 AFLglobal.com 1 ( 8 00) 8 66-7385 © 2004, AFL, all rights reserved. P P - 3-00909, Revision 7 , 4.27.2026 Specications are subject to change without notice. 461 Standard C ompression – ACSR Tee Connector—5500 Series for ACSR Conductors, Open Run (cont.) CONDUCTOR CATALOG NUMBER DIE SIZE WEIGHT DIMENSIONS CODE WORD SIZE STRANDING DIA. RUN CONDUCTOR BRANCH CONDUC - TOR ALUMINUM HEX DIE RUN BRANCH A B KCMIL AL/ST IN LBS KG LBS KG IN MM IN MM Tern 795.0 45/7 1.063 5530.3 30.116 30AH 3.3 1.50 1.7 0.77 19.1 486 9.4 240 Condor 795.0 54/7 1.093 5530.3 30.116 30AH 3.3 1.50 1.7 0.77 19.1 486 9.4 240 Drake 795.0 26/7 1.108 5530.3 30.116 30AH 3.3 1.50 1.7 0.77 19.1 486 9.4 240 Mallard 795.0 30/19 1.140 5530.3 30.122 30AH 3.3 1.50 1.7 0.77 19.1 486 9.4 240 Cuckoo 795.0 24/7 1.092 5530.3 30.116 30AH 3.3 1.50 1.7 0.77 19.1 486 9.4 240 Ruddy 900.0 45/7 1.131 5530.3 30.122 30AH 3.3 1.50 1.7 0.77 19.1 486 9.4 240 Canary 900.0 54/7 1.162 5530.3 30.122 30AH 3.3 1.50 1.7 0.77 19.1 486 9.4 240 Catbird 954.0 36/1 1.140 5530.3 30.122 30AH 3.3 1.50 1.7 0.77 19.1 486 9.4 240 Rail 954.0 45/7 1.165 5530.3 30.122 30AH 3.3 1.50 1.7 0.77 19.1 486 9.4 240 Cardinal 954.0 54/7 1.196 5530.3 30.125 30AH 3.3 1.50 1.7 0.77 19.1 486 10.1 256 Tanager 1033.5 36/1 1.186 5530.3 30.125 30AH 3.3 1.50 1.7 0.77 19.1 486 10.1 256 0rtolan 1033.5 45/7 1.212 5534.3 34.128 34AH 4.5 2.04 2.2 1.00 20.1 511 10.1 256 Curlew 1033.5 54/7 1.244 5534.3 34.134 34AH 4.5 2.04 2.2 1.00 20.1 511 10.1 256 Bluejay 1113.0 45/7 1.259 5534.3 34.134 34AH 4.5 2.04 2.2 1.00 20.1 511 10.1 256 Bunting 1192.5 45/7 1.302 5534.3 34.138 34AH 4.5 2.04 2.2 1.00 20.1 511 10.1 256 Bittern 1272.0 45/7 1.345 5536.3 36.144 36AH 5.0 2.27 2.5 1.13 21.0 533 10.6 270 Pheasant 1272.0 54/19 1.382 5536.3 36.147 36AH 5.0 2.27 2.5 1.13 21.0 533 10.6 270 Dipper 1351.5 45/7 1.386 5536.3 36.147 36AH 5.0 2.27 2.5 1.13 21.0 533 10.6 270 Martin 1351.5 54/19 1.424 5538.3 38.150 38AH 5.9 2.68 3.0 1.36 21.9 556 11.2 284 Bobolink 1431.0 45/7 1.427 5538.3 38.150 38AH 5.9 2.68 3.0 1.36 21.9 556 11.2 284 Plover 1431.0 54/19 1.465 5538.3 38.156 38AH 5.9 2.68 3.0 1.36 21.9 556 11.2 284 Nuthatch 1510.5 45/7 1.466 5538.3 38.156 38AH 5.9 2.68 3.0 1.36 21.9 556 11.2 284 Parrot 1510.5 54/19 1.506 5540.3 40.162 40AH 6.6 2.99 3.4 1.54 22.8 578 11.8 298 Lapwing 1590.0 45/7 1.504 5540.3 40.162 40AH 6.6 2.99 3.4 1.54 22.8 578 11.8 298 Falcon 1590.0 54/19 1.545 5540.3 40.162 40AH 6.6 2.99 3.4 1.54 22.8 578 11.8 298 Chukar 1780.0 84/19 1.602 5542.3 42.178 42AH 7.7 3.49 3.9 1.77 23.6 600 12.4 314 — 2034.0 72/7 1.681 5544.3 44.175 44AH 6.8 3.08 4.0 1.81 24.5 622 12.0 305 Bluebird 2156.0 84/19 1.762 5544.3 44.184 44AH 6.8 3.08 4.0 1.81 24.5 622 12.0 305 Kiwi 2167.0 72/7 1.737 5544.3 44.181 44AH 6.8 3.08 4.0 1.81 24.5 622 12.0 305 Thrasher 2312.0 76/19 1.802 5544.3 44.188 44AH 6.8 3.08 4.0 1.81 24.5 622 12.0 305 Joree 2515.0 76/19 1.880 5548.3 48.197 48AH 9.1 4.13 5.2 2.36 24.5 622 14.0 356
462 AFLglobal.com 1 ( 8 00) 8 66-7385 © 2004, AFL, all rights reserved. P P - 3-00910, Revision 6, 4.27.2026 Specications are subject to change without notice. 462 Standard C ompression – AAC Tee Connector—5500 Series for AAC Conductors, Open Run The 5500 Series Tee Connector is a permanent drop designed for AAC conductors. The tee connector is fabricated from AFL seamless drawn aluminum. The run portion incorporates an improved design of interlocking extrusions, providing a permanent grip on the conductor when compressed. The branch portion of the tee connector is designed for limited tension use, maintaining a minimum of 40% of the ASTM rated strength of the conductor on which it is being used. For die size sections 30AH and above, the end tapers of the compression portions of all compression accessories are supplied with a high voltage finish. Ordering Instructions Step 1: Determine Run Catalog Number Determine the run catalog number based on the conductor being used. Step 2: Determine Branch Catalog Number Determine the branch catalog number based on the conductor being used. Step 3: Assemble Catalog Number Example: For 795 Arbutus conductor in both the Run and Branch, the complete catalog number is: 5530.3 – 30.109 Run Catalog Number + Notes: 1. AFL Filler Compound (AFC) Requirements are on page 115. 2. Installation Instructions for Open Run Tee Connectors are on page 145. Branch Catalog Number
463 AFLglobal.com 1 ( 8 00) 8 66-7385 © 2004, AFL, all rights reserved. P P - 3-00910, Revision 6, 4.27.2026 Specications are subject to change without notice. 463 Standard C ompression – AAC Tee Connector—5500 Series for AAC Conductors, Open Run (cont.) CONDUCTOR CATALOG NUMBER DIE SIZE WEIGHT DIMENSIONS CODE WORD SIZE STRANDING DIA. RUN CONDUCTOR BRANCH CONDUCTOR RUN BRANCH A B KCMIL AL IN LBS KG LBS KG IN MM IN MM Aster 2/0 7 0.414 5574 74.438 74AH 0.2 0.10 0.2 0.09 7.6 192 5.5 140 Phlox 3/0 7 0.464 5574 74.484 74AH 0.2 0.10 0.8 0.09 7.6 192 5.5 140 Oxlip 4/0 7 0.522 5575 75.547 75AH 0.4 0.18 0.3 0.14 8.6 217 6.0 152 Laurel 266.8 19 0.593 5575 75.609 75AH 0.4 0.18 0.3 0.14 8.6 217 6.0 152 Tulip 336.4 19 0.666 5576 76.688 76AH 0.7 0.30 0.5 0.23 10.0 254 6.5 165 Canna 397.5 19 0.724 5576 76.750 76AH 0.7 0.30 0.5 0.23 10.0 254 6.5 165 Goldentuft 450.0 19 0.770 5520.3 20.812 20AH 1.0 0.45 0.6 0.27 14.5 368 7.6 164 Yarrow 450.0 37 0.772 5520.3 20.812 20AH 1.0 0.45 0.6 0.27 14.5 368 7.6 164 Cosmos 477.0 19 0.793 5520.3 20.812 20AH 1.0 0.45 0.6 0.27 14.5 368 7.6 164 Syringa 477.0 37 0.795 5520.3 20.812 20AH 1.0 0.45 0.6 0.27 14.5 368 7.6 164 Cosmos 477.0 19 0.793 5524.3 24.875 24AH 1.7 0.77 0.8 0.36 15.5 394 8.3 210 Syringa 477.0 37 0.795 5524.3 24.875 24AH 1.7 0.77 0.8 0.36 15.5 394 8.3 210 Zinnia 500.0 19 0.811 5524.3 24.875 24AH 1.7 0.77 0.8 0.36 15.5 394 8.3 210 Hyacinth 500.0 37 0.813 5524.3 24.875 24AH 1.7 0.77 0.8 0.36 15.5 394 8.3 210 Dahlia 556.5 19 0.856 5524.3 24.938 24AH 1.7 0.77 0.8 0.36 15.5 394 8.3 210 Mistletoe 556.5 37 0.858 5524.3 24.938 24AH 1.7 0.77 0.8 0.36 15.5 394 8.3 210 Meadowsweet 600.0 37 0.891 5524.3 24.938 24AH 1.7 0.77 0.8 0.36 15.5 394 8.3 210 Orchid 636.0 37 0.918 5524.3 24.969 24AH 1.7 0.77 0.8 0.36 15.5 394 8.3 210 Heuchera 650.0 37 0.928 5524.3 24.969 24AH 1.7 0.77 0.8 0.36 15.5 394 8.3 210 Flag 700.0 61 0.964 5527.3 27.100 27AH 2.7 1.22 1.3 0.59 18.3 464 8.8 225 Violet 715.5 37 0.974 5527.3 27.106 27AH 2.7 1.22 1.3 0.59 18.3 464 8.8 225 Nasturtium 715.5 61 0.975 5527.3 27.106 27AH 2.7 1.22 1.3 0.59 18.3 464 8.8 225 Petunia 750.0 37 0.997 5527.3 27.106 27AH 2.7 1.22 1.3 0.59 18.3 464 8.8 225 Cattail 750.0 61 0.998 5527.3 27.106 27AH 2.7 1.22 1.3 0.59 18.3 464 8.8 225 Arbutus 795.0 37 1.026 5530.3 30.109 30AH 3.3 1.50 1.7 0.77 19.1 486 9.4 240 Lilac 795.0 61 1.028 5530.3 30.109 30AH 3.3 1.50 1.7 0.77 19.1 486 9.4 240 — 800.0 37 1.031 5530.3 30.109 30AH 3.3 1.50 1.7 0.77 19.1 486 9.4 240 Heliotrope 800.0 61 1.031 5530.3 30.109 30AH 3.3 1.50 1.7 0.77 19.1 486 9.4 240 Snapdragon 900.0 61 1.094 5530.3 30.116 30AH 3.3 1.50 1.7 0.77 19.1 486 9.4 240 Magnolia 954.0 37 1.124 5530.3 30.122 30AH 3.3 1.50 1.7 0.77 19.1 486 9.4 240 Goldenrod 954.0 61 1.126 5530.3 30.122 30AH 3.3 1.50 1.7 0.77 19.1 486 9.4 240 Camellia 1000.0 61 1.152 5530.3 30.122 30AH 3.3 1.50 1.7 0.77 19.1 486 9.4 240 Bluebell 1033.5 37 1.170 5530.3 30.122 30AH 3.3 1.50 1.7 0.77 19.1 486 9.4 240 Larkspur 1033.5 61 1.172 5530.3 30.122 30AH 3.3 1.50 1.7 0.77 19.1 486 9.4 240 Marigold 1113.0 61 1.216 5534.3 34.128 34AH 4.5 2.04 2.2 1.00 20.1 511 10.1 256 Hawthorn 1192.5 61 1.258 5534.3 34.134 34AH 4.5 2.04 2.2 1.00 20.1 511 10.1 256
464 AFLglobal.com 1 ( 8 00) 8 66-7385 © 2004, AFL, all rights reserved. P P - 3-00910, Revision 6, 4.27.2026 Specications are subject to change without notice. 464 Standard C ompression – AAC CONDUCTOR CATALOG NUMBER DIE SIZE WEIGHT DIMENSIONS CODE WORD SIZE STRANDING DIA. RUN CONDUCTOR BRANCH CONDUCTOR RUN BRANCH A B KCMIL AL IN LBS KG LBS KG IN MM IN MM Narcissus 1272.0 61 1.300 5534.3 34.134 34AH 4.5 2.04 2.2 1.00 20.1 511 10.1 256 Columbine 1351.0 61 1.340 5536.3 36.144 36AH 5.0 2.27 2.5 1.13 21.0 533 10.6 270 Carnation 1431.0 61 1.379 5536.3 36.144 36AH 5.0 2.27 2.5 1.13 21.0 533 10.6 270 — 1500.0 91 1.412 5536.3 36.147 36AH 5.0 2.27 2.5 1.13 21.0 533 10.6 270 Gladiolus 1510.5 61 1.187 5536.3 36.147 36AH 5.0 2.27 2.5 1.13 21.0 533 10.6 270 Coreopsis 1590.0 61 1.250 5538.3 38.156 38AH 5.9 2.68 3.0 1.36 21.9 556 11.2 284 Dogwood 1590.0 91 1.454 5538.3 38.156 38AH 5.9 2.68 3.0 1.36 21.9 556 11.2 284 Jessamine 1750.0 61 1.525 5540.3 40.162 40AH 6.6 2.99 3.4 1.54 22.8 578 11.8 298 Cowslip 2000.0 91 1.630 5542.3 42.178 42AH 7.7 3.49 3.9 1.77 23.6 600 12.4 314 Sagebrush 2250.0 91 1.729 5544.3 44.181 44AH 6.8 3.08 4.0 1.81 24.5 622 12.0 305 — 2300.0 61 1.750 5544.3 44.181 44AH 6.8 3.08 4.0 1.81 24.5 622 12.0 305 — 2300.0 91 1.750 5544.3 44.181 44AH 6.8 3.08 4.0 1.81 24.5 622 12.0 305 Lupine 2500.0 91 1.823 5544.3 44.188 44AH 6.8 3.08 4.0 1.81 24.5 622 12.0 305 Bitterroot 2750.0 91 1.912 5548.3 48.197 48AH 9.1 4.13 5.2 2.36 24.5 622 14.0 358 Tee Connector—5500 Series for AAC Conductors, Open Run (cont.)
Features:
- Aluminum alloy
- Compression connectors
- Meets the standards of NEMA CC1
Applications:
- Rated for 230 kV
- Substation
- Aluminum cable
Substation tee connector is designed for limited space application as found in substations. Run and tap lengths are shorter than conventional tee connectors which saves space and minimizes birdcaging problems. Tee connector is installed with standard ACA hex dies.
230 kV Aluminum Compression Couplers,230 kV Aluminum Compression Terminal Connectors,230 kV Aluminum Welded Bus Pipe Couplers,230 kV Aluminum Welded Bus Pipe Elbows,230 kV Aluminum Welded Bus Pipe Supports,230 kV Aluminum Welded Bus Pipe Tee and Vee Connectors,230 kV Aluminum Welded Bus Pipe Terminal Connectors,230 kV Aluminum Welded Bus Pipe to Cable Couplers,230 kV Aluminum Welded Bus Pipe to Cable Tee,230 kV Aluminum Welded Cable Terminal,230 kV Aluminum Welded End Plugs,230 kV Aluminum Welded Grounding Rod,230 kV Aluminum Welded Pipe Taps,230 kV Aluminum Welded Stud to Bus Pipe Couplers
250
Close
230 kV Aluminum Compression Tee Connectors
Features:
- Aluminum alloy
- Compression connectors
- Meets the standards of NEMA CC1
Applications:
- Rated for 230 kV
- Substation
- Aluminum cable
PRODUCT DESCRIPTION
Substation tee connector is designed for limited space application as found in substations. Run and tap lengths are shorter than conventional tee connectors which saves space and minimizes birdcaging problems. Tee connector is installed with standard ACA hex dies.
Documents & Downloads
Close
Specification Sheet
- Download Specification Sheet