The long limiter link has a dual function of serving as a connecting coupler as well as a fuse. The fusible section determines the time-current characteristics of each size.
52a8df1c09764d8682f3d27d16f0da42
1 AFLglobal.com 1 (800) 890-8878 © 2011, AFL, all rights reserved. PP-3-00116, Revision 3, 11.12.2025 Specifications are subject to change without notice. 1 Network Underground The long limiter link has a dual function of serving as a connecting coupler as well as a fuse. The fusible section determines the time-current characteristics of each size. This is made to close tolerances to insure consistent conformity with the fusing time-current curves. The limiter will not clear the circuit on system overloads but will clear the circuit on faults severe enough to cause cable insulation damage. Type NRLA-PL3 Long Limiter Link for Paper Insulated Cable* L B B A Ordering Information Catalog Number Cable Size Indents in Cable Cocket Dimensions in inches A** B L NRLA21-PL3 4/0 STR 1 11/16 3 8 7/8 NRLA25-PL3 250 MCM 1 3/4 3 1/8 8 7/8 NRLA30-PL3 300 MCM 2 13/16 3 1/2 9 5/8 NRLA35-PL3 350 MCM 2 7/8 3 1/2 9 5/8 NRLA40-PL3 400 MCM 2 31/32 3 1/2 9 5/8 NRLA50-PL3 500 MCM 2 1 1/16 4 1/4 11 1/2 NRLA75-PL3 750 MCM 2 1 5/16 4 1/4 11 3/4 * Closed end of sockets are sealed to make sockets oil tight. ** Diameter AFL’s Dossert ® product line offers a wide range of substation accessories in low voltage up to 765 kV applications in bronze or aluminum materials.
Features:
- Tin-plated copper alloy
Applications:
- Network Underground
- Copper cable
The long limiter link has a dual function of serving as a connecting coupler as well as a fuse. The fusible section determines the time-current characteristics of each size. This is made to close tolerances to insure consistent conformity with the fusing time-current curves. The limiter will not clear the circuit on system overloads but will clear the circuit on faults severe enough to cause cable insulation damage.
C Tapered Compression Sleeve | AFL,CKS Compression Receptacle for MICON Outlets | AFL,LLA 2P1 Limiter Terminal Insulating Sleeve | AFL,CBR Insulated Crab Connector | AFL,LLA 2P2 Limiter Terminal Shell | AFL,LLA 2PL123 Long Limiter Terminal Assembly | AFL,LLA-2PL3 Long Limiter Terminal for Underground Copper Networks | AFL,LLA-2R123 and LLA-2P123 Limiter Terminal Assembly | AFL,LLA-2R3 and LLA-2P3 Limiter Terminal for Underground Networks | AFL,High-Strength MA Cable Receptacle for MICON Outlets | AFL,MICON Coupling MIC Conductor Accessories | AFL,MICON Outlet Plugs P Conductor Accessories | AFL
908