Fuentes de luz óptica y medidores de potencia de la serie Contractor: herramientas del tamaño de la palma de la mano diseñadas para probar enlaces de red de fibra monomodo y multimodo. Con un peso de sólo 0,4 libras, las unidades de la serie Contractor son ideales para su uso en el campo.
da86d2f7a1b8412082179962debd95bf,2d6219b67b3b4ccfbd4cb3226f97b3ea
1 Test & Inspection AFLglobal.com | 800.235.3423 Optical Loss Testing FlowScout ® Through-Mode PON Optical Power Meter ©2021-2024, AFL, all rights reserved. TPPM-00-2000 Revision AC 2024-01-18 Specifications are subject to change without notice . AFL is a trusted supplier of optical testing equipment with more than 30 years of experience and tens of thousands of units in the field. AFL’s full range of N.I.S.T. traceable power meters are used for testing single-mode and/or multimode fiber networks. Designed for all: AFL’s power meters are designed to meet the demands in an outside plant environment. The FlowScout Through-Mode PON Power Meter (TPPM) easily withstands a one-meter drop and has splash resistant controls that are easy to use, even with gloves on. Flexible and efficient: A range of field-swappable output adapters support multiple connector styles and enables access for easy cleaning. The efficient design ensures a long run time from its rechargeable Li-Polymer battery and includes an auto-off feature to save power. Stores test results: The built-in File Management system allows technicians to organize test results into multiple files and transfer them via USB to a PC for analyzing, generating reports, and printing. The FlowScout’s QR code feature can easily collect and transfer test data via any smart devices. Features • Detect multiple wavelengths automatically - NO setup required! • Detects GPON, XGS-PON, and Video signals all at once • Rugged and water resistant, IP54 rating • Field-swappable connector adapters • Large color touchscreen display daylight viewable • Rechargeable Li-Polymer battery Applications • Detects and measures PON upstream and downstream signals • PON network activation • BPON, EPON, GPON, 10G-EPON, XG-PON, XGS-PON, Video network verification and troubleshooting • Evaluate PON power level Pass/Fail based on limits US Patent 9,602,200 and US Patent 10,771,153
2 3 Test & Inspection Test & Inspection AFLglobal.com | 800.235.3423 AFLglobal.com | 800.235.3423 Optical Loss Testing Optical Loss Testing FlowScout ® Through-Mode PON Optical Power Meter FlowScout ® Through-Mode PON Optical Power Meter ©2021-2024, AFL, all rights reserved. TPPM-00-2000 Revision AC 2024-01-18 Specifications are subject to change without notice . © 2021-2024, AFL, all rights reserved. TPPM-00-2000 Revision AC 2024-01-18 Specifications are subject to change without notice . GENERAL Power Rechargeable Li-Polymer battery Adapter Caps SC APC standard, LC APC available Battery Life >8 hours Recharge time ~4 hours Operating Temperature -10 °C to 50 °C, 95 % RH (non-condensing) Storage Temperature -20 °C to 60 °C, 95 % RH (non-condensing) Size (H x W x D) 17.1 x 10.4 x 4.6 cm (6.75 x 4.1 x 1.8 in) Weight 0.59 kg (1.3 lb) Notes: a. All specifications valid at 25°C unless otherwise specified. b. Accuracy was measured at 25 ºC and -10 dBm per N.I.S.T. standards. Ordering Information All models include PON optical power meter, rechargeable batteries, SC/APC adapter cap, two SC/APC-SC/APC jumpers, USB-A to USB-C cable for charging and data transfer, AC plug, and carry case. Quick reference quide is available at www.AFLglobal.com. DESCRIPTION AFL NO. FlowScout PON optical power meter XGPON/XGSPON TPPM-XG INCLUDED ACCESSORIES (2) SC/APC to SC/APC Test Jumpers, 2 m 8700-00-0090MR USB-A to USB-C Charge and Data Transfer Cable 6000-00-0036MR AC Adapter 4050-00-0034MR One-Click ® Cleaner Mini-500 SC, ST, FC (500+ cleans) 8500-05-0009MZ AFL ships one power plug (of customer choice) along with the order. Please select one out of the four plugs listed below. EU Power Plug for AC charger 4050-00-0034EUMR US power plug for AC charger 4050-00-0034USMR CN/AUS power plug for AC charger 4050-00-0034SAAMR UK power plug for AC charger 4050-00-0034UKMR Specifications a OPTICAL MODEL TPPM-XG Upstream Wavelength 1270 nm 1310 nm Measurement Range -28 to +13 dBm -28 to +13 dBm Downstream Wavelength 1490 nm 1550 nm 1577 nm Measurement Range -50 to +13 dBm -35 to +26 dBm -50 to +17 dBm Accuracy b ±0.50 dB @0 dBm Resolution 0.01 dB Insertion Loss 1.7 dB Typical Inline ORL 55 dB typical Measurement Units dBm, μW Recommended Products Optical Light Sources • Encircled Flux Compliant • 5-Year Product Warranty • Integrated LED and Laser light sources One-Click ® Cleaners • Patented single-action • Variety of sizes and types • Low cost per clean VFI4 Visual Fault Identifier • Eye-safe Class 3R visible red laser source, 650 nm • Output power of <= 5.0 mW with 10 km range • Universal connector interface for quick connection Qualifications CATEGORY REGULATION/STANDARD QUALIFICATION CE Marking EU Compliant to relevant EU Directives on health, safety, and environmental protection, and certified with CE marking UKCA Marking UK Compliant to relevant UK Directives on health, safety, and environmental protection, and certified with the UKCA marking Safety/EMC/EMI IEC Compliant to IEC 61010-1 for safety requirements for electrical equipment EN Compliant to EN 61010-1 for safety requirements for electrical equipment IEC Compliant to IEC 61326-1 for EMC requirements for electrical equipment EN Compliant to EN 61326-1 for EMC requirements for electrical equipment EN Compliant to EN 55011 for EMC requirements for industrial, scientific and medical equipment RoHS EU Compliant to EU regulations Directive 2011/65/EU (RoHS 2) and Directive 2015/863 (RoHS 3) Test Method TIA Compliant to TIA-568.3-D for test and measurement requirements for premises optical fiber cabling and components IEC Compliant to IEC 11801 for test and measurement requirements for optical fiber cabling for use within premises EN Compliant to EN 50173 for test and measurement requirements for optical fiber cabling for use within premises AS/NZS Compliant to AS/NZS 3080 for test and measurement requirements for optical fiber cabling for use within premises TIA Compliant to TIA-526-7 for test procedures for installed optical fiber cable plant TIA Compliant to TIA-526-14 for test procedures for installed optical fiber cable plant IEC Compliant to IEC 14763-3 for systems and methods for the inspection and testing of installed optical fiber cabling AS/NZS Compliant to AS/NZS 14763.3 for systems and methods for the inspection and testing of installed optical fiber cabling IEC Compliant to IEC 61280-4-1 for test procedures for installed optical fiber cable plant IEC Compliant to IEC 61280-4-2 for test procedures for installed optical fiber cable plant Generic Requirement IEC Compliant to IEC 61315 for requirements on calibration of fibre-optic power meters Contact Sales@AFLglobal.com to schedule a demonstration or learn how to buy. Visit www.AFLglobal.com/Test to learn more about FlowScout PON optical power meters. International Sales and Service Contact Information available at www.AFLglobal.com/Test/Contacts
Características:
- Herramientas robustas y fiables del tamaño de la palma de la mano
- Garantía de 5 años líder en el sector
- Rentable y fácil de usar
- Apagado automático para maximizar la duración de la batería del medidor de potencia
Aplicaciones:
- Mediciones de pérdida de enlaces
- Certificar los enlaces SM &
MM según las normas del sector - Comprobación de la continuidad e identificación de la fibra antes del empalme por fusión
Las fuentes de luz y los medidores de potencia de la serie Contractor son instrumentos de prueba robustos diseñados con una interfaz de usuario sencilla y respaldados por una garantía de 5 años líder en el sector. Las opciones de kits monomodo y multimodo ofrecen herramientas para medir la pérdida de inserción de la red, comprobar la continuidad e identificar la fibra.
Medidor de potencia CSM1
- Cuatro modelos proporcionan amplios rangos de longitudes de onda y niveles de potencia
- Almacena referencias ópticas para cada longitud de onda calibrada
- Detecta automáticamente los tonos de prueba para su uso en la identificación de fibras
El puerto de entrada óptica acepta una variedad de tapas adaptadoras de rosca
Fuente láser CSS1-SM
- Salida de láser de 1310 nm y 1550 nm desde un único puerto de prueba
- El puerto de salida acepta adaptadores roscados UCI (FC, SC, ST, LC) para mayor flexibilidad y acceso a la fibra de lanzamiento para su limpieza e inspección
Fuente LED CSS1-MM
- Salida de LED de 850 nm y 1300 nm desde un único puerto de prueba
- Mandriles de 50 μm y 62,5 μm incluidos
- Tonos de prueba (2000, 1000, 330, 270 Hz) para la identificación de la fibra
- Utilice medidores de potencia cuando el técnico tenga acceso al extremo de la fibra
Transmisión de fuentes CSS1:
- Salida de onda continua CW (DC)
- Tonos de prueba (2000, 1000, 330, 270 Hz) para la identificación de la fibra
- Utilice medidores de potencia cuando el técnico tenga acceso al extremo de la fibra
- Utilice OFI (identificador de fibra óptica) para las pruebas en la mitad del tramo
Consulte la hoja de especificaciones para ver la lista completa de modelos y accesorios opcionales. 
Sistema de inspección de conectores de fibra óptica FOCIS Flex,VFI4 Identificador visual de fallos,Limpiadores One-Click
1100