Les connecteurs de robinet à coin AFL sont utilisés pour réaliser des connexions électriques complètes entre aluminium et aluminium et entre aluminium et cuivre.
6cd173dcc58345fb96ab18fa89d7a0a8
3 © 2018, AFL, all rights reserved. PP-3-00826,Revision 7, 7.2.2026 S p e c i c a t i o n s a r e s u b j e c t t o c h a n g e w i t h o u t n o t i c e . 3 TAPLINK ® Wedge Connectors AFLglobal.com/contact Sales & Support WTA Series #6 - 4/0 Series Wedge Tap Connectors Features • Material - Connector Body—Aluminum Alloy - Connector Wedge—Aluminum Alloy - Breakaway Bolt—Aluminum - Retaining Ring—Steel - Connector Interface—6101-T6 • Breakaway Bolt Torque: 10-12 ft-lbs - Bolt Head size: 5/8" AFL Wedge Tap Connectors are used to make complete aluminum-to-aluminum and aluminum-to-copper electrical connections. The bolted wedge technology makes installations quicker, easier and safer when compared with traditional tap connectors by eliminating the need for specialized tooling for the same type of connection. Once the appropriate pressure is obtained by the wedge, the breakaway bolt will shear off giving a visual indication that a correct installation has been made. The connector is rated for the full current of the conductors within its range. As the conductors expand and contract under thermal cycling, the C-shaped body operates within the elastic region of its mechanical properties, allowing the connection to maintain constant pressure, resulting in reliability of performance. This connector is reusable and can easily be removed by backing out the bolt, which will drive out the wedge. AFL recommends replacing the bolt and applying more inhibitor grease when reusing. The wedge tap connectors are comprised of high strength aluminum castings, a breakaway bolt and a highly conductive aluminum interface, providing a secure, reliable solution with an installation that is both fast and simple. continued Standard Packaging Quantity Weight 50 25 lbs CONNECTOR BODY CONNECTOR WEDGE WEDGE INTERFACE BREAKAWAY BOLT RETAINING RING * Not rated for HT Conductors Applications • For use on ACSR, AAC and AAAC conductors • For Aluminum-to-Copper connections, the copper wire should be located on the bottom in order to minimize contamination.
4 © 2018, AFL, all rights reserved. PP-3-00826,Revision 7, 7.2.2026 S p e c i c a t i o n s a r e s u b j e c t t o c h a n g e w i t h o u t n o t i c e . 4 TAPLINK ® Wedge Connectors AFLglobal.com/contact Sales & Support Contact AFL for further details. Qualifications Governing Body Standard Code ANSI C119.4 WTA Series #6 - 4/0 Series Wedge Tap Connectors (cont.) Ordering Information Line No. AFL No. Run Tap CPI No. Conductor Size Conductor Diameter Range Conductor Size Conductor Diameter Range 1 WTA-162/162 #6 0.162" - 0.232" #6, #4 SOLID 0.162" - 0.204" 640101 2 WTA-232/162 #4, #2, #1 AAC 0.232" - 0.328" #6, #4 SOLID 0.162" - 0.231" 240100 3 WTA-232/232 #4 0.232" - 0.291" 240101 4 WTA-232/292 #2, #1 AAC 0.292" - 0.328" 240102 5 WTA-354/198 #1 ACSR, 1/0, 2/0 AAC 0.354" - 0.414" #6 ACSR, #4 AAC 0.198" - 0.231" 210103 6 WTA-354/232 #4 AAC, #2, #1 AAC 0.232" - 0.353" 210105 7 WTA-354/354 #1 ACSR, 1/0, 2/0 AAC 0.354" - 0.414" 210106 8 WTA-447/198 2/0 ACSR, 3/0 0.447" - 0.502" #6 ACSR, #4 AAC 0.198" - 0.231" 230107 9 WTA-447/232 #4, #2 AAC 0.232" - 0.291" 230108 10 WTA-447/292 #2 AAC, #1 0.292" - 0.353" 230109 11 WTA-447/354 #1 ACSR, 1/0, 2/0 AAC 0.354" - 0.446" 230110 12 WTA-447/447 2/0 ACSR, 3/0 0.447" - 0.502" 230111 13 WTA-502/198 3/0 ACSR, 4/0, 250 AAC 0.502" - 0.574" #6 ACSR, #4 AAC 0.198" - 0.249" 264111 14 WTA-502/250 #4 ACSR, #2, #1 AAC 0.250" - 0.353" 264112 15 WTA-502/354 #1 ACSR, 1/0, 2/0 AAC 0.354" - 0.446" 264113 16 WTA-502/447 2/0 ACSR, 3/0 0.447" - 0.521" 264114 17 WTA-502/522 4/0, 250 AAC 0.522" - 0.574" 264115 * For Replacement Breakaway Bolts, see page 17 of the TAPLINK ® catalog for ordering information.
5 © 2018, AFL, all rights reserved. PP-3-00827, Revision 7, 7.6.2026 S p e c i c a t i o n s a r e s u b j e c t t o c h a n g e w i t h o u t n o t i c e . 5 TAPLINK ® Wedge Connectors AFLglobal.com/contact Sales & Support continued WTA Series 350 Series Wedge Tap Connectors CONNECTOR BODY CONNECTOR WEDGE WEDGE INTERFACE BREAKAWAY BOLT RETAINING RING * Not rated for HT Conductors Features • Material - Connector Body—Aluminum Alloy - Connector Wedge—Aluminum Alloy - Breakaway Bolt—Aluminum - Retaining Ring—Steel - Connector Interface—6101-T6 • Breakaway Bolt Torque: 10-12 ft-lbs - Bolt Head size: 5/8" AFL Wedge Tap Connectors are used to make complete aluminum-to-aluminum and aluminum-to-copper electrical connections. The bolted wedge technology makes installations quicker, easier and safer when compared with traditional tap connectors by eliminating the need for specialized tooling for the same type of connection. Once the appropriate pressure is obtained by the wedge, the breakaway bolt will shear off giving a visual indication that a correct installation has been made. The connector is rated for the full current of the conductors within its range. As the conductors expand and contract under thermal cycling, the C-shaped body operates within the elastic region of its mechanical properties, allowing the connection to maintain constant pressure, resulting in reliability of performance. This connector is reusable and can easily be removed by backing out the bolt, which will drive out the wedge. AFL recommends replacing the bolt and applying more inhibitor grease when reusing. The wedge tap connectors are comprised of high strength aluminum castings, a breakaway bolt and a highly conductive aluminum interface, providing a secure, reliable solution with an installation that is both fast and simple. Standard Packaging Quantity Weight 50 25 lbs Applications • For use on ACSR, AAC and AAAC conductors • For Aluminum-to-Copper connections, the copper wire should be located on the bottom in order to minimize contamination.
6 © 2018, AFL, all rights reserved. PP-3-00827, Revision 7, 7.6.2026 S p e c i c a t i o n s a r e s u b j e c t t o c h a n g e w i t h o u t n o t i c e . 6 TAPLINK ® Wedge Connectors AFLglobal.com/contact Sales & Support Contact AFL for further details. Qualifications Governing Body Standard Code ANSI C119.4 WTA Series 350 Series Wedge Tap Connectors (cont.) Ordering Information Line No. AFL No. Run Tap CPI No. Conductor Size Conductor Diameter Range Conductor Size Conductor Diameter Range 1 WTA-609/162 266.8 ACSR, 300 MCM, 336.4 AAC, 336.4 ACSR 18/1, 350 MCM 0.609" - 0.684" #6, #4 AAC 0.162" - 0.231" 350117 2 WTA-609/232 #4 0.232" - 0.291" 350118 3 WTA-609/292 #2, #1 AAC 0.292" - 0.327" 350119 4 WTA-609/328 #1, 1/0 AAC 0.328" - 0.397" 350120 5 WTA-609/398 1/0 ACSR, 2/0 0.398" - 0.446" 350121 6 WTA-609/447 2/0 ACSR, 3/0 0.447" - 0.521" 350122 7 WTA-609/522 4/0, 250 0.522" - 0.591" 350123 8 WTA-609/592 266.8 -19 AAC, 300 AAC, 266.8 ACSR 0.592" - 0.664" 350124 9 WTA-609/665 300 ACSR 26/7, 350, 336.4 18/1 0.665" - 0.684" 350125 * For Replacement Breakaway Bolts, see page 17 of the TAPLINK ® catalog for ordering information.
7 © 2018, AFL, all rights reserved. PP-3-00828,Revision 7, 7.6.2026 S p e c i c a t i o n s a r e s u b j e c t t o c h a n g e w i t h o u t n o t i c e . 7 TAPLINK ® Wedge Connectors AFLglobal.com/contact Sales & Support continued WTB Series 336.4 - 636 Series Wedge Tap Connectors CONNECTOR BODY WEDGE INTERFACE BREAKAWAY BOLT CONNECTOR WEDGE RETAINING RING * Not rated for HT Conductors Features • Material - Connector Body—Aluminum Alloy - Connector Wedge—Aluminum Alloy - Breakaway Bolt—Aluminum - Retaining Ring—Steel - Connector Interface—6101-T6 • Breakaway Bolt Torque: 10-12 ft-lbs - Bolt Head size: 3/4" AFL Wedge Tap Connectors are used to make complete aluminum-to-aluminum and aluminum-to-copper electrical connections. The bolted wedge technology makes installations quicker, easier and safer when compared with traditional tap connectors by eliminating the need for specialized tooling for the same type of connection. Once the appropriate pressure is obtained by the wedge, the breakaway bolt will shear off giving a visual indication that a correct installation has been made. The connector is rated for the full current of the conductors within its range. As the conductors expand and contract under thermal cycling, the C-shaped body operates within the elastic region of its mechanical properties, allowing the connection to maintain constant pressure, resulting in reliability of performance. This connector is reusable and can easily be removed by backing out the bolt, which will drive out the wedge. AFL recommends replacing the bolt and applying more inhibitor grease when reusing. The wedge tap connectors are comprised of high strength aluminum castings, a breakaway bolt and a highly conductive aluminum interface, providing a secure, reliable solution with an installation that is both fast and simple. Standard Packaging Quantity Weight 25 32 lbs Applications • For use on ACSR, AAC and AAAC • For Aluminum-to-Copper connections, the copper wire should be located on the bottom in order to minimize contamination.
8 © 2018, AFL, all rights reserved. PP-3-00828,Revision 7, 7.6.2026 S p e c i c a t i o n s a r e s u b j e c t t o c h a n g e w i t h o u t n o t i c e . 8 TAPLINK ® Wedge Connectors AFLglobal.com/contact Sales & Support * For Replacement Breakaway Bolts, see page 17 of the TAPLINK ® catalog for ordering information. Contact AFL for further details. Qualifications Governing Body Standard Code ANSI C119.4 WTB Series 336.4 - 636 Series Wedge Connectors (cont.) Ordering Information Line No. AFL No. Run Tap CPI No. Conductor Size Conductor Diameter Range Conductor Size Conductor Diameter Range 1 WTB-666/162 336.4, 350 MCM, 397 ACSR 18/1 0.666" - 0.743" #6, #4 0.162" - 0.256" 336200 2 WTB-666/257 #4 ACSR, #2, 1/0 AAC 0.257" - 0.367" 336104 3 WTB-666/368 1/0, 2/0, 3/0 0.368" - 0.521" 336012 4 WTB-666/522 4/0 ACSR, 266.8 AAC 0.522" - 0.641" 336866 5 WTB-666/642 266.8 ACSR 36/7, 336.4, 397.5 0.642" - 0.806" 336718 6 WTB-769/184 397 ACSR 24/7, 450 MCM, 477, 500 MCM, 556.5 AAC 0.769" - 0.858" #6 AAC, #4, #2 0.184" - 0.316" 477057 7 WTB-769/292 #2, 1/0 0.292" - 0.398" 477962 8 WTB-769/398 1/0 ACSR, 2/0, 3/0 AAC 0.398" - 0.501" 477853 9 WTB-769/502 3/0 ACSR, 4/0, 250, 266.8, 300 AAC 0.502" - 0.627" 477724 10 WTB-769/628 266.8 ACSR 36/7, 300 AAC, 336.4, 397.5 ACSR 24/7 0.628" - 0.772" 477633 11 WTB-769/720 336.4 ACSR 26/7, 397, 477, 500 MCM, 556 AAC 0.720" - 0.858" 477434 12 WTB-856/162 477 ACSR 26/7, 556, 600 MCM, 636 ACSR 18/1, 605 ACSR 0.856" - 0.953" #6, #4, #2 0.162" - 0.316" 556956 13 WTB-856/292 #2, #1, 1/0 0.292" - 0.398" 556892 14 WTB-856/368 1/0, 2/0, 3/0, 4/0 AAC 0.368" - 0.521" 556783 15 WTB-856/522 4/0, 250, 266.8, 300 MCM, 336 AAC, 350 MCM 0.522" - 0.679" 556638 16 WTB-856/680 350 MCM, 336.4, 397.5, 477 AAC 0.680" - 0.806" 556504 17 WTB-856/795 397 ACSR 30/7, 477, 500 MCM, 556.5, 636 AAC 0.795" - 0.918" 556294 18 WTB-856/914 556.5 ACSR 24/7, 636 AAC, 636 ACSR 18/1, 605 0.914" - 0.952" 556294-1
9 © 2018, AFL, all rights reserved. PP-3-00829,Revision 7, 7.6.2026 S p e c i c a t i o n s a r e s u b j e c t t o c h a n g e w i t h o u t n o t i c e . 9 TAPLINK ® Wedge Connectors AFLglobal.com/contact Sales & Support continued WTC Series 795 - 1272 Series Wedge Tap Connectors CONNECTOR BODY WEDGE INTERFACE CONNECTOR WEDGE BREAKAWAY BOLT RETAINING RING * Not rated for HT Conductors Features • Material - Connector Body—Aluminum Alloy - Connector Wedge—Aluminum Alloy - Breakaway Bolt—Aluminum - Retaining Ring—Steel - Connector Interface—6101-T6 • Breakaway Bolt Torque: 10-12 ft-lbs - Bolt Head size: 3/4" AFL Wedge Tap Connectors are used to make complete aluminum-to-aluminum and aluminum-to-copper electrical connections. The bolted wedge technology makes installations quicker, easier and safer when compared with traditional tap connectors by eliminating the need for specialized tooling for the same type of connection. Once the appropriate pressure is obtained by the wedge, the breakaway bolt will shear off giving a visual indication that a correct installation has been made. The connector is rated for the full current of the conductors within its range. As the conductors expand and contract under thermal cycling, the C-shaped body operates within the elastic region of its mechanical properties, allowing the connection to maintain constant pressure, resulting in reliability of performance. This connector is reusable and can easily be removed by backing out the bolt, which will drive out the wedge. AFL recommends replacing the bolt and applying more inhibitor grease when reusing. The wedge tap connectors are comprised of high strength aluminum castings, a breakaway bolt and a highly conductive aluminum interface, providing a secure, reliable solution with an installation that is both fast and simple. Standard Packaging Quantity Weight 20 40 lbs Applications • For use on ACSR, AAC and AAAC • For Aluminum-to-Copper connections, the copper wire should be located on the bottom in order to minimize contamination.
10 © 2018, AFL, all rights reserved. PP-3-00829,Revision 7, 7.6.2026 S p e c i c a t i o n s a r e s u b j e c t t o c h a n g e w i t h o u t n o t i c e . 10 TAPLINK ® Wedge Connectors AFLglobal.com/contact Sales & Support * For Replacement Breakaway Bolts, see page 17 of the TAPLINK ® catalog for ordering information. Contact AFL for further details. Qualifications Governing Body Standard Code ANSI C119.4 WTC Series 795 - 1272 Series Wedge Tap Connectors (cont.) Ordering Information Line No. AFL NO. Run Tap CPI No. Conductor Size Conductor Diam - eter Range Conductor Size Conductor Diam - eter Range 1 WTC-973/162 636 ACSR, 715, 750 MCM, 795, 900 MCM 0.973" - 1.108" #6, #4, #2 AAC 0.162" - 0.315" 795454 2 WTC-973/316 #2 ACSR, #1, 1/0, 2/0 AAC 0.316" - 0.446" 795360 3 WTC-973/447 2/0 ACSR, 3/0, 4/0, 250 AAC 0.447" - 0.585" 795218 4 WTC-973/586 266.8, 300 MCM, 350 MCM, 336.4 ACSR 18/1 0.586" - 0.719" 795050 5 WTC-973/720 336.4 ACSR 26/7, 450 MCM, 500 MCM, 477, 556.5 AAC 0.720" - 0.878" 795920 6 WTC-973/879 477 ACSR 30/7, 556.5 ACSR, 600 MCM, 605 MCM, 636 ACSR 18/1, 715.5 AAC 0.879" - 0.990" 795730 7 WTC-973/991 636 ACSR 26/7, 750 MCM, 715, 795, 900 MCM 0.991" - 1.108" 795594 8 WTC-1124/162 954, 900 ACSR, 1000 MCM, 1113 AAC, 1033.5 AAC 1.124" - 1.196" #6, #4, #2 AAC 0.162" - 0.315" 954420 9 WTC-1124/316 #2 ACSR, #1, 1/0, 2/0 AAC 0.316" - 0.446" 954320 10 WTC-1124/447 2/0 ACSR, 3/0, 4/0, 250 AAC 0.447" - 0.585" 954175 11 WTC-1124/586 266.8, 300 MCM, 350 MCM, 366.4 ACSR 18/1 0.586" - 0.719" 954030 12 WTC-1124/720 366.4 ACSR 26/7, 450 MCM, 397.5, 477, 500 MCM, 556.5 AAC 0.720" - 0.857" 954870 13 WTC-1124/858 477 ACSR 26/7, 556, 605, 715 AAC, 636 ACSR 26/7 0.858" - 0.999" 954660 14 WTC-1124/1000 666.6 ACSR 24/7, 715 ACSR, 795, 900 AAC 1.000" - 1.106" 954484 15 WTC-1124/1107 795 ACSR 26/7, 954, 1113 MCM, 900 ACSR, 1000 MCM, 1033.5 AAC 1.107" - 1.196" 954390 16 WTC-1212/162 1033.5 ACSR, 1113 ACSR, 1192 AAC, 1272 AAC 1.212" - 1.300" #6, #4, #2 AAC 0.162" - 0.315" 103370 17 WTC-1212/316 #2 ACSR, #1, 1/0, 2/0 AAC 0.316" - 0.446" 103260 18 WTC-1212/447 2/0 ACSR, 3/0, 4/0 AAC 0.447" - 0.562" 103110 19 WTC-1212/563 4/0 ACSR, 250 MCM, 266.8, 300 MCM 0.563" - 0.664" 103945 20 WTC-1212/665 350 MCM, 336.4, 397.5, 450 MCM 0.665" - 0.794" 103780 21 WTC-1212/795 397.5 ACSR 30/7, 477, 500 MCM, 556 AAC, 600 MCM 0.795" - 0.913" 119793 22 WTC-1212/914 556.5 ACSR 24/7, 636, 715 ACSR 24/7, 750 MCM, 795 AAC 0.914" - 1.039" 103680 23 WTC-1212/1040 795 ACSR 36/1, 900, 954 AAC, 1000 AAC, 1113 MCM 1.040" - 1.161" 103580 24 WTC-1212/1162 900 ACSR 45/7, 1033.5, 954 ACSR, 1192.5 AAC 1.162" - 1.258" 103380 25 WTC-1212/1212 1113 ACSR, 1272 AAC 1.212" - 1.300" 119250
11 © 2019, AFL, all rights reserved. PP-3-00862,Revision 1, 7.6.2026 S p e c i c a t i o n s a r e s u b j e c t t o c h a n g e w i t h o u t n o t i c e . 11 TAPLINK ® Wedge Connectors AFLglobal.com/contact Sales & Support continued WTA Series #4 - 350 Copper Series Wedge Tap Connectors Features • Material - Connector Body—Bronze Alloy - Connector Wedge—Bronze Alloy - Breakaway Bolt—Stainless Steel - Retaining Ring—Zinc-Plated Steel - Connector Interface—Copper • Breakaway Bolt Torque: 10 ft-lbs - Replacement Bolt part number (pack of 10): D13096-1SSPK AFL's Copper Wedge Tap Connectors are used to make complete copper-to-copper electrical connections. The bolted wedge technology makes installations quicker, easier and safer when compared with traditional tap connectors by eliminating the need for specialized tooling for the same type of connection. Once the appropriate pressure is obtained by the wedge, the breakaway bolt will shear off giving a visual indication that a correct installation has been made. The connector is rated for the full current of the conductors within its range. This connector is reusable and can easily be removed by backing out the bolt, which will drive out the wedge. AFL recommends replacing the bolt and applying more inhibitor grease when reusing. The wedge tap connectors are comprised of high strength bronze castings, a breakaway bolt and a highly-conductive copper interface, providing a secure, reliable solution with an installation that is both fast and simple. Standard Packaging Quantity Weight 25 50 lbs CONNECTOR BODY CONNECTOR WEDGE WEDGE INTERFACE BREAKAWAY BOLT RETAINING RING * Not rated for HT Conductors Applications • For use on stranded and solid copper conductors
12 © 2019, AFL, all rights reserved. PP-3-00862,Revision 1, 7.6.2026 S p e c i c a t i o n s a r e s u b j e c t t o c h a n g e w i t h o u t n o t i c e . 12 TAPLINK ® Wedge Connectors AFLglobal.com/contact Sales & Support WTA Series #4 - 350 Copper Series Wedge Tap Connectors (cont.) Ordering Information Line No. AFL No. Run Tap CPI No. Copper Conductor Size Conductor Diameter Range Copper Conductor Size Conductor Diameter Range 1 WTA-232/162CU #4 STR #2 (STR & SOL) #1 STR 0.232" - 0.328" #6 SOL - #4 SOL 0.162" - 0.231" 240100C 2 WTA-232/232CU #4 STR - #2 SOL 0.232" - 0.260" 240101C 3 WTA-232/292CU #1 SOL - #2 STR 0.281" - 0.328" 240102C 4 WTA-354/198CU 1/0 STR 2/0 STR 0.354" - 0.419" #6 SOL - #4 SOL 0.162" - 0.231" 210103C 5 WTA-354/232CU #4 STR - #2 STR 0.232" - 0.353" 210104C, 210105C 6 WTA-354/354CU 1/0 STR - 2/0 STR 0.354" - 0.419" 210106C 7 WTA-447/198CU 3/0 STR 0.447" - 0.502" #6 SOL - #4 SOL 0.162" - 0.231" 230107C 8 WTA-447/232CU #4 STR - #2 SOL 0.232" - 0.260" 230108C 9 WTA-447/292CU #1 SOL - #2 STR 0.281" - 0.353" 230109C 10 WTA-447/354CU 1/0 STR - 2/0 STR 0.354" - 0.446" 230110C 11 WTA-447/447CU 3/0 STR 0.447" - 0.502" 230111C 12 WTA-502/198CU 4/0 STR 0.500" - 0.530" #6 SOL - #2 SOL 0.162" - 0.260" 264110C, 264111C 13 WTA-502/250CU #1 SOL - #2 STR 0.250" - 0.353" 264112C 14 WTA-502/354CU 1/0 STR - 2/0 STR 0.354" - 0.446" 264113C 15 WTA-502/447CU 3/0 STR 0.440" - 0.521" 264114C 16 WTA-502/522CU 4/0 STR 0.500" - 0.530" 264115C 17 WTA-609/162CU 300 MCM 350 MCM 0.609" - 0.684" #8 STR- #4 SOL 0.132" - 0.231" 350117C 18 WTA-609/232CU #4 STR - #1 SOL 0.232" - 0.291" 350118C 19 WTA-609/292CU #2 STR 0.292" - 0.327" 350119C 20 WTA-609/328CU #1 - 1/0 STR 0.328" - 0.397" 350120C 21 WTA-609/398CU 2/0 STR 0.395" - 0.446" 350121C 22 WTA-609/447CU 3/0 STR 0.447" - 0.521" 350122C 23 WTA-609/522CU 4/0 STR, 250 MCM 0.522" - 0.591" 350123C 24 WTA-609/592CU 300 MCM 0.592" - 0.664" 350124C 25 WTA-609/665CU 350 MCM 0.665" - 0.684" 350125C Contact AFL for further details. Qualifications Governing Body Standard Code ANSI C119.4
Caractéristiques :
- Avantages
- Pas d'outils d'installation spéciaux par rapport aux connecteurs cunéiformes "Fired-on".
- Le corps spécial en "C" assure une pression constante lors des cycles thermiques.
- Le boulon à tête de cisaillement assure un couple constant à chaque installation.
- Pré-rempli d'un composé inhibiteur
- Testé selon la norme C119.4
- Approuvé pour une utilisation sur ACSR, AAC et AAAC.
- Non approuvé pour une utilisation sur les conducteurs à haute température
- Pour les connexions aluminium-cuivre
Colliers de serrage rainure parallle PG | AFL Global Canada,Connecteurs de ligne directe TAPLINK | AFL Global Canada,Connecteurs pour robinets TAPLINK Wedge Pad | AFL Global Canada,Connecteurs d'triers cale TAPLINK. | AFL Global Canada
2623