Le Wrapping Tube Cable (WTC) de 250 µm avec SpiderWeb Ribbon® (SWR) est un câble extérieur de très haute densité conçu spécifiquement pour les marchés de la fibre optique jusqu'au domicile (FTTH) ou de l'accès.
700fa7f356564df8aa34c82971bfe193,afd032fdb57447dea95901bc8e46975d
1 AFLglobal.com 1 (800) 866-7385 © 2017, AFL, all rights reserved. P P -1-00128, Revision 21, 3.11.2025 Speci≤cations are subject to change without notice. Fiber Optic Cable 1 Wrapping Tube Cable (WTC) with SpiderWeb Ribbon ® (SWR ® ) – 250 μm Fiber/250 μm Pitch The 250 μm Fiber/250 μm Pitch Wrapping Tube Cable (WTC), with SpiderWeb Ribbon ® (SWR ® ), is an ultra-high density outside plant cable designed specifically for fiber-to-the-home (FTTH) or access markets. It is compliant with the latest issue of the outside plant cable standard, Telcordia GR-20. With an ultra-high density and a new ribbon technology called SpiderWeb Ribbon ® , WTC provides the smallest cable diameter and lowest weight, high-fiber count ribbon cable in the industry. WTC with SWR ® cables are available in fiber counts from 48 to 1,728. SWR ® is a bonded fiber ribbon design allowing for either a highly efficient ribbon splicing or an individual fiber breakout splicing process. This flexibility allows for a single cable design to cover a diverse set of applications from access networks to high-fiber count mass fusion splicing. With the ability to roll and conform, the SWR ® provides for ultra-high density packaging in the WTC. SWR Technology 12F SWR ® Armored 4-rod FRP (288F - 1,728F) Multiple 12F SWR ® Bundle Contrahelical dual binder system Rip cord Water blocking tape Armor Dielectric Strength Member (FRP) Rods SWR Inner Jacket (MDPE) Rip cord Rip cord Non-armored & Armored 2-rod FRP (48F - 144F) Non-armored 4-rod FRP (288F - 1,728F) Applications • Data Center Inter-building Connections • Access Provider Metro Rings • Service Provider FTTx • Cable TV Subscriber Networks • Metro Rail Track-side Network Links • Suitable for Aerial Lashing, Pulled-in-duct, Air-Jetted-in-Duct, and Direct Buried (armored only) • Campus LAN Features • Build America/Buy America options available • Collapsible ribbon reduces size of cable compared to other encapsulated or pliable ribbon technologies • Design optimizes the fiber packing density making WTC/SWR cables the smallest ribbon cables without compromising robustness of the cable • Small-diameter cable allows more optical fibers to be placed into crowded or limited-space pathways • Light weight for easy handling in the field compared to traditional cables • Completely Gel-free for reduced time to access fiber and prep for splicing continued
2 AFLglobal.com 1 (800) 866-7385 © 2017, AFL, all rights reserved. P P -1-00128, Revision 21, 3.11.2025 Speci≤cations are subject to change without notice. Fiber Optic Cable 2 Optical Fiber Fiber Type (Fiber Count) Fiber Designator Fiber Diameter Fiber Pitch Standard MFD Maximum Attenuation (cabled) dB/km 1310 nm 1550 nm 250 μm Single-mode (48F to 864F) 9 250 μm 250 μm ITU-T G.652.D and G.657.A1 9.2 ± 0.4 μm ≤ 0.40 ≤ 0.30 Fujikura SR15E (144F to 1728F) K 250 μm 250 μm ITU-T G.652.D and G.657.A1 8.6 ± 0.4 μm ≤ 0.40 ≤ 0.30 BABA-Compliant Single-mode (48F to 864F) BK 250 μm 250 μm ITU-T G.652.D and G.657.A1 9.2 ± 0.4 μm ≤ 0.40 ≤ 0.30 BABA-Compliant Corning Single-mode (48F to 864F) BL 250 μm 250 μm ITU-T G.652.D and G.657.A1 9.2 ± 0.4 μm ≤ 0.40 ≤ 0.30 Wrapping Tube Cable (WTC) with SpiderWeb Ribbon ® (SWR ® ) – 250 μm Fiber/ 250 μm Pitch NOTES: For Fiber Type, replace “ X ” in the AFL No. with the character in the “Fiber Designator” field of the Optical Fiber table below. To designate length markings in AFL No., replace “ L ” in the AFL No. with “F” for Feet or “M” for Meters. * For BABA-compliant Wrapping Tube Cable, add -B to the end of the AFL No. ** Modified temperature performance – see Temperature Specifications table on page 3. Mechanical Data AFL No. Fiber Count Binder Unit Nominal Diameter Weight Short Term/Installation Long Term/Storage/Static inches (mm) lbs/1,000 ft (kg/km) Max Tensile Load lbs (N) Min Bend Radius inches (mm) Max Tensile Load lbs (N) Min Bend Radius inches (mm) Non-Armored LWSE-48- X -C-48-1-00N1D- L* 48 1 X 48F 0.43 (11.0) 61 (90) 607 (2700) 8.7 (221) 182 (810) 6.5 (165) LWSE-72- X -C-72-1-00N1D- L* 72 1 X 72F 0.43 (11.0) 61 (90) 607 (2700) 8.7 (221) 182 (810) 6.5 (165) LWSE-96- X -C-96-1-00N1D- L* 96 1 X 96F 0.43 (11.0) 64 (95) 607 (2700) 8.7 (221) 182 (810) 6.5 (165) LWSE-144- X -C-144-1-00N1D- L* 144 1 X 144F 0.43 (11.0) 61 (90) 607 (2700) 8.7 (221) 182 (810) 6.5 (165) LWSE-288- X -C-288-1-00N1D- L* 288 1 X 288F 0.47 (12.0) 71 (105) 607 (2700) 9.5 (242) 182 (810) 7.1 (181) LWSE-432- X -C-72-6-00N1D- L* 432 6 X 72F 0.53 (13.5) 91 (135) 607 (2700) 10.6 (270) 182 (810) 8.0 (203) LWSE-576- X -C-72-8-00N1D- L* 576 8 X 72F 0.59 (15.0) 111 (165) 607 (2700) 11.8 (300) 182 (810) 8.9 (226) LWSE-864- X -C-72-12-00N1D- L* 864 12 X 72F 0.69 (17.5) 145 (215) 607 (2700) 13.8 (351) 182 (810) 10.3 (262) LWSE-1152-K-C-144-8-00N1D- L* 1152 8 X 144F 0.73 (18.5) 161 (240) 607 (2700) 14.6 (371) 182 (810) 10.9 (277) LWSE-1728-K-C-144-12-00N1D- L* 1728 12 X 144F 0.91 (23.0) 242 (360) 607 (2700) 18.1 (460) 182 (810) 13.6 (346) Armored LWSE-144- X -C-144-1-10S1D- L* 144 1 X 144F 0.63 (16.0) 148 (220) 607 (2700) 12.6 (320) 182 (810) 9.5 (242) LWSE-288- X -C-288-1-10S1D- L* 288 1 X 288F 0.69 (17.5) 172 (255) 607 (2700) 13.8 (351) 182 (810) 10.3 (262) LWSE-432- X -C-72-6-10S1D- L* 432 6 X 72F 0.75 (19.0) 202 (300) 607 (2700) 15.0 (381) 182 (810) 11.2 (285) LWSE-576- X -C-72-8-10S1D- L* 576 8 X 72F 0.81 (20.5) 235 (350) 607 (2700) 16.1 (409) 182 (810) 12.1 (307) LWSE-864- X -C-72-12-10S1D- L* 864 12 X 72F 0.91 (23.0) 286 (425) 607 (2700) 18.1 (460) 182 (810) 13.6 (346) LWSE-1728-K-C-144-12-10S1D- L* 1728 ** 12 X 144F 1.14 (29.0) 410 (610) 607 (2700) 22.8 (579) 182 (810) 17.1 (435) continued Ordering Information Example: For BABA-compliant, 864F Wrapping Tube Cable with BABA-compliant Corning single-mode fiber and length markings in feet, order AFL No. LWSE-864-BL-C-72-12-10S1D-F-B Base Part Number: LWSE-864- X -C-72-12-10S1D- L* BL: BABA-Compliant Corning Single-mode Fiber F: Feet Markings -B: BABA-Complaint Wrapping Tube Cable Option
3 AFLglobal.com 1 (800) 866-7385 © 2017, AFL, all rights reserved. P P -1-00128, Revision 21, 3.11.2025 Speci≤cations are subject to change without notice. Fiber Optic Cable 3 Contact AFL for further details. Qualifications Governing Body Standard Code Component Telcordia GR-20 Fiber Optic Cable Temperature Specifications Temperature Range 1728F Armored Operation -40ºF to +158ºF (-40ºC to +70ºC) -4ºF to +158ºF (-20ºC to +70ºC) Storage -40ºF to +158ºF (-40ºC to +70ºC) -4ºF to +158ºF (-20ºC to +70ºC) Installation -22ºF to +140ºF (-30ºC to +60ºC) -4ºF to +140ºF (-20ºC to +60ºC) Fiber Count Binder Unit (BU) Ring Markings 48F No Binder Unit 1-4 Ring Marking 72F No Binder Unit 1-6 Ring Marking 96F No Binder Unit 1-8 Ring Marking 144F No Binder Unit 1-12 Ring Marking 288F No Binder Unit 1-24 Ring Marking 432F 6 Binder Units 1 2 3 4 5 6 1-6 Ring Marking 576F 8 Binder Units 1 2 3 4 5 6 7 8 864F 12 Binder Units 1 2 3 4 5 6 7 8 9 10 11 12 1152F 8 Binder Units 1 2 3 4 5 6 7 8 1-12 Ring Marking 1728F 12 Binder Units 1 2 3 4 5 6 7 8 9 10 11 12 1-12 Ring Marking Stripe Ring Fiber Identification R No. Stripe Ring Marking R No. Stripe Ring Marking R No. Stripe Ring Marking R No. Stripe Ring Marking 1 7 13 19 2 8 14 20 3 9 15 21 4 10 16 22 5 11 17 23 6 12 18 24 Wrapping Tube Cable (WTC) with SpiderWeb Ribbon ® (SWR ® ) – 250 μm Fiber/ 250 μm Pitch
Caractéristiques :
- Construction prête pour l'accès (ARC)
- Technologie de fibre optique SpiderWeb Ribbon (SWR)
- Densité de fibres nettement supérieure à celle des câbles rubans traditionnels
- Diamètres et poids de câble plus petits
- Technologie de blocage de l'eau complètement sèche
- Faisceaux de rubans compacts
- Paquets blindés et non blindés
- Entièrement conforme à la norme Telcordia GR-20
Les applications:
- Connexions inter-bâtiments des centres de données
- Anneaux métropolitains du fournisseur d'accès
- Fournisseur de services FTTx
- Réseaux d'abonnés à la télévision par câble
- Liaisons réseau côté voie du métro
- Convient à l'arrimage aérien, à la traction dans le conduit et à la projection dans le conduit.
- Campus LAN
Le câble tubulaire enveloppant (WTC) 250 µm , avec ruban en toile d'araignée® (SWR®), est un câble d'installation extérieure à ultra-haute densité conçu spécifiquement pour les marchés de la fibre optique jusqu'au domicile (FTTH) ou de l'accès. Il est conforme à la dernière version de la norme sur les câbles d'installations extérieures, Telcordia GR-20. Grâce à une densité ultra-élevée et à une nouvelle technologie de ruban appelée SpiderWeb Ribbon®, WTC offre le plus petit diamètre de câble et le poids le plus faible pour un câble ruban à nombre de fibres élevé de l'industrie. Les câbles WTC avec TOS® sont disponibles dans des nombres de fibres allant de 144 à 3 456.
SWR® est une conception de ruban de fibres collées permettant une épissure de ruban très efficace ou un processus d'épissure de fibre individuelle. Cette flexibilité permet à un seul câble de couvrir un ensemble diversifié d'applications, des réseaux d'accès à l'épissurage par fusion de masse à nombre élevé de fibres. Grâce à sa capacité à rouler et à se conformer, le SWR®
permet un emballage à ultra-haute densité dans le WTC.

200 um Wrapping Tube Cable WTC avec TOS,Série LMZ OFNG LS IO MicroCore,Câble MicroCore Interconnect Premise,Câble MicroCore Interconnect Premise avec technologie SWR SpiderWeb Ribbon,Câble en fibre MicroCore durci avec technologie de ruban SpiderWeb,Câble à fibres optiques MicroCore renforcé,Câble à fibre optique MicroCore 20 pour locaux sous-unités,Locaux sous unitisés MicroCore 30,Locaux sous-unités MicroCore 30 Base 12,MicroCore 30 de Premise sous unitisé avec la technologie de ruban SpiderWeb,Ultra HD MicroCore