Les sources lumineuses de la série OLS sont des unités de terrain idéales pour les techniciens qui certifient les réseaux monomodes et multimodes.
4d07f194fd8b4666a9aac10352a9ea49
AFLglobal.com 1 (800) 235-3423 © 2021-2025, AFL, all rights reserved. OLS0-00-2000 Revision AC 2022-03-27 Specifications are subject to change without notice. Test and Inspection OLS Series Light Sources 1 AFL is a trusted supplier of optical testing equipment with more than 30 years of experience and tens of thousands of units in use in the field. AFL’s full range of light sources are used for testing single-mode and/or multimode fiber networks. Sources with wave ID can transmit two or more wavelengths simultaneously – decreasing test time and reducing user errors when paired with AFL wave ID power meters. Designed for the real world: AFL’s light sources were designed to meet the demands of the outside plant environment. They withstand the one-meter drop and have splash resistant controls that are easy to use, even with gloves on. Flexible and efficient: A range of field-swappable output adapters enables access for cleaning optical ports and supports multiple connector styles. The efficient design provides long test time from globally available AA batteries. External power adapter available for extended testing or lab situations. Reduce test time and errors: Wave ID (Dual or Single) decreases test time while reducing technician errors and CW mode provides continuous output (no encoding). Supported output modes: Test Tone (2000, 1000, 330, 270 Hz) for use in fiber identification with AFL brand power meters, OTDRs (with fiber end access) or Optical Fiber Identifier (OFI) products for non-intrusive, mid-span testing. Features • Rugged, dependable, and backed by industry-best 5-year warranty • Generates up to three Wave ID wavelengths simultaneously - slashing test time • Field-swappable connector adapters for maximum flexibility • Long battery life from globally available AA batteries Applications • Certify multimode and single-mode links per TIA/EIA standards • Link loss measurements • Pair with power meters, OTDRs or OFIs for testing • Fiber identification for splicing and continuity checking OLS2 Dual Optical Laser Source
2 AFLglobal.com 1 (800) 235-3423 © 2021-2025, AFL, all rights reserved. OLS0-00-2000 Revision AC 2022-03-27 Specifications are subject to change without notice. Test and Inspection OLS Series Light Sources 2 OLS Series Models and Applications Model MM / SM Wavelengths (nm) Applications OLS1-Dual MM 850, 1300 Ethernet, Token Ring, and FDDI Fiber Links OLS2-Dual SM 1310, 1550 SM Networks, LAN/WAN Testing Specifications a,e Optical Specifications - OLS2-Dual and OLS1-Dual Models Model OLS1-Dual (Single Port b ) OLS2-Dual (Single Port) Wavelength 850 ±30 nm 1300 +30/-20 nm 1310 ±20 nm 1550 ±20 nm Spectral Width 45 nm (typ); 60 nm (max) 120 nm (typ); 170 nm (max) 5 nm (max) Emitter Type LED Laser Safety Class Class I FDA 21 CFR 1040.10 and 1040.11, IEC 60825-1: 2007-03 Output Power >-20 dBm, 62.5 μm multimode c 0 dBm, 9 μm single-mode d Output Stability ±0.1 dB over 8 hours (after 5 minutes warm-up) ±0.05 dB over 1 hour (after 15 minutes warm-up) ±0.1 dB over 8 hours (after 15 minutes warm-up) Tone Output N/A 270 Hz, 330 Hz, 1 kHz, 2 kHz General Specifications: All OLS Models Available Adapters SC FC, ST, LC Power 2 AA batteries, optional AC adapter Battery Life SM port: 72 hours typical (40 hours minimum). MM port: 30 hours typical (20 hours minimum) Operating Temperature -10 °C to 50 °C, 95 % RH (non-condensing) Storage Temperature -30 °C to 60 °C, 95 % RH (non-condensing) Size (H x W x D) 14.0 x 8.1 x 3.8 cm (5.5 x 3.2 x 1.5 in) Weight 0.29 kg (0.65 lb) Notes: a. All specifications valid at 25°C unless otherwise specified. b. May be used to test 50 or 62.5 μm fiber with supplied mandrels. c. Output power will be approximately 3 dB less if a 50 μm mandrel-wrapped jumper is used instead of a 62.5 μm mandrel-wrapped jumper. d. Adjustable 2 dB. e. All OLS products come with the UPC optical port. Ordering Information When ordering, specify connector type at the end of model number (e.g. OLS2-DUAL-SC). All OLS models include protective rubber boot, 2 AA batteries, carry case. AC adapters are available (ordered separately), see table below. Test jumpers and connector adapters are required for operation (purchased separately). Test jumpers with a variety of connector styles and fiber types and adapter caps for most common connectors may be purchased from AFL. AFL NO. Output Wavelengths (nm) Output Ports Emitter Type Wave ID Transmit Available Connectors Power 850 1300 1310 1550 OLS1-DUAL 1 LED FC, SC, ST, LC (2) AA, AC OLS2-DUAL 1 Laser FC, SC, ST, LC (2) AA, AC
AFLglobal.com 1 (800) 235-3423 © 2021-2025, AFL, all rights reserved. OLS0-00-2000 Revision AC 2022-03-27 Specifications are subject to change without notice. Test and Inspection OLS Series Light Sources 3 OLS Connector Adapters and AC Adapter AFL NO. Description 2900-50-0002MR FC connector adapter 2900-50-0003MR SC connector adapter 2900-50-0004MR ST connector adapter 2900-50-0006MR LC connector adapter 8800-00-0072PR Universal flip-top dust cap for UCI outputs 4050-00-0119PR 100-240 VAC to 9 VDC, AC adapter Qualificati ons Category Regulation/Standard Qualification CE Marking EU Compliant to relevant EU Directives on health, safety, and environmental protection, and certified with CE marking Safety/EMC/EMI IEC Compliant to IEC 61010-1 for safety requirements for electrical equipment EN Compliant to EN 61010-1 for safety requirements for electrical equipment IEC Compliant to IEC 61326-1 for EMC requirements for electrical equipment EN Compliant to EN 61326-1 for EMC requirements for electrical equipment EN Compliant to EN 55011 for EMC requirements for industrial, scientific and medical equipment FDA Compliant to code of federal regulations FDA 21 CFR 1040.10 and 1040.11 on laser products IEC Compliant to IEC 60825-1 for safety of laser products RoHS EU Compliant to EU regulations Directive 2011/65/EU (RoHS 2) and Directive 2015/863 (RoHS 3) Test Method TIA Compliant to TIA-568.3-D for test and measurement requirements for premises optical fiber cabling and components* IEC Compliant to IEC 11801 for test and measurement requirements for optical fiber cabling for use within premises* EN Compliant to EN 50173 for test and measurement requirements for optical fiber cabling for use within premises* AS/NZS Compliant to AS/NZS 3080 for test and measurement requirements for optical fiber cabling for use within premises* TIA Compliant to TIA-526-7 for test procedures for installed optical fiber cable plant TIA Compliant to TIA-526-14 for test procedures for installed optical fiber cable plant* IEC Compliant to IEC 14763-3 for systems and methods for the inspection and testing of installed optical fiber cabling* AS/NZS Compliant to AS/NZS 14763.3 for systems and methods for the inspection and testing of installed optical fiber cabling* IEC Compliant to IEC 61280-4-1 for test procedures for installed optical fiber cable plant* IEC Compliant to IEC 61280-4-2 for test procedures for installed optical fiber cable plant * A complementary encircled flux mode conditioner may be needed to comply with encircled flux launch conditions for testing multimode optical fiber cabling and components Contact Sales@AFLglobal.com to schedule a demonstration or learn how to buy. Visit www.AFLglobal.com/Test to learn more about OLS series light sources. International Sales and Service Contact Information available at www.AFLglobal.com/Test/Contacts Recommended Products One-Click ® Cleaners • Patented single-action • Variety of sizes and types • Low cost per clean OFI-BIPM Optical Fiber Identifier • World class signal sensitivity • Trigger lock, positive stop for optimum detection • Integrated optical power meter option
Caractéristiques :
- Robuste, fiable et couvert par une garantie de 5 ans, la meilleure du secteur.
- Génère jusqu'à trois longueurs d'onde Wave ID simultanément, ce qui réduit le temps de test.
- Adaptateurs de connecteurs interchangeables sur le terrain pour une flexibilité maximale.
- Longue durée de vie des piles AA disponibles dans le monde entier
Les applications:
- Certifier des liens multimodes et monomodes selon les normes TIA/EIA
- Mesures de la perte de liaison
- Appariement avec des wattmètres, des OTDR ou des OFI pour les tests.
- Identification des fibres pour l'épissurage et le contrôle de continuité
L'AFL est un fournisseur de confiance d'équipements de test optique, avec plus de 30 ans d'expérience et des dizaines de milliers d'unités utilisées sur le terrain. La gamme complète de sources lumineuses d'AFL’est utilisée pour tester les réseaux de fibres monomodes et/ou multimodes. Les sources avec identification d'onde peuvent transmettre deux ou plusieurs longueurs d'onde simultanément – diminuant le temps de test et réduisant les erreurs de l'utilisateur lorsqu'elles sont associées aux wattmètres AFL wave ID.
Conçu pour le monde réel : Les sources lumineuses d'AFL’ont été conçues pour répondre aux exigences de l'environnement extérieur des usines. Ils résistent à une chute d'un mètre et sont dotés de commandes résistantes aux éclaboussures qui sont faciles à utiliser, même avec des gants.
Flexible et efficace : Une gamme d'adaptateurs de sortie interchangeables sur le terrain permet d'accéder aux ports optiques de nettoyage et prend en charge plusieurs styles de connecteurs. La conception efficace permet une longue durée de test avec des piles AA disponibles dans le monde entier. Un adaptateur électrique externe est disponible pour les tests prolongés ou les situations de laboratoire.
Réduire la durée des tests et les erreurs : L'identification des ondes (triple, double ou simple) diminue le temps de test tout en réduisant les erreurs des techniciens et le mode CW fournit une sortie continue (sans codage).
Modes de sortie pris en charge : Tonalité de test (2000, 1000, 330, 270 Hz) à utiliser pour l'identification des fibres avec les wattmètres de marque AFL, les OTDR (avec accès à l'extrémité de la fibre) ou les produits Optical Fiber Identifier (OFI) pour des tests non intrusifs à mi-portée.
Voir la fiche technique pour la liste complète des modèles et des accessoires en option.

Sources lumineuses et compteurs de puissance de la série Contractor,Sources lumineuses et compteurs de puissance de la série Contractor,Mesureurs de puissance optique OPM5 et OPM4,Adaptateurs de port de test
197