Le connecteur de goujon est conçu pour être utilisé sur des goujons en aluminium. Le connecteur de câble est doté d'une rainure universelle qui permet de choisir un conducteur en cuivre pour chaque taille.
0404a973ff1249859851295871ad551c
162 Bronze Stud Connectors Bronze Stud Connectors © 2011, AFL, all rights reserved. PP-3-00376, Revision 1, 8.7.13 Specifications are subject to change without notice. www.AFLglobal.com or 800-890-8878 A HERCULON ™ variable type connector for joining a cable or a wire to a threaded stud. The stud end of the connector can also be furnished to accommodate a plain stud or pipe. Material Copper Alloy Hardware Everdur bolts, nuts and lockwashers Notes • Other sizes of studs and various threads to the inch can be promptly furnished. • For two 500 MCM cables to a .75" T16 stud order HS2C75-50-T16 • For three 500 MCM cables to a .75" T16 stud order HS3C75-50-T16 • For two 500 MCM cables to a .75" T0 stud order HS2C75-50-T0 TYPE HSC, HS2C, HS3C Copper Stud Connector for Cable or Wire. HSC connects one conductor to a stud, HS2C connects two conductors to a stud, and HS3C connects three conductors to a stud. HSC HS2C B A HS2C HSC HS3C HS3C
163 Bronze Stud Connectors Bronze Stud Connectors © 2011, AFL, all rights reserved. PP-3-00376, Revision 1, 8.7.13 Specifications are subject to change without notice. www.AFLglobal.com or 800-890-8878 TYPE HSC, HS2C, HS3C Copper Stud Connector for Cable or Wire. HSC connects one conductor to a stud, HS2C connects two conductors to a stud, and HS3C connects three conductors to a stud. Ordering Information CATALOG NUMBER STUD DIA THREADS PER INCH CABLE RANGE DIMENSIONS IN INCHES BOLT SIZE HSC HS2C HS3C MIN MAX A B HSC50-4-T13 HS2C50-4-T13 HS3C50-4-T13 1/2 13 8 Solid 4 Stranded 2 5/8 3/8 HSC50-8-T13 HS2C50-8-T13 HS3C50-8-T13 1/2 13 4 Solid 1 Stranded 2 7/8 3/8 HSC50-13-T13 HS2C50-13-T13 HS3C50-13-T13 1/2 13 1 Stranded 2/0 Stranded 2 1 3/8 HSC50-21-T13 HS2C50-21-T13 HS3C50-21-T13 1/2 13 2/0 Stranded 4/0 Stranded 2 1 1/8 3/8 HSC63-13-T18 HS2C63-13-T18 HS3C63-13-T18 5/8 18 1 Stranded 2/0 Stranded 2 1 3/8 HSC63-21-T18 HS2C63-21-T18 HS3C63-21-T18 5/8 18 2/0 Stranded 4/0 Stranded 2 1 1/8 3/8 HSC63-30-T18 HS2C63-30-T18 HS3C63-30-T18 5/8 18 4/0 Stranded 300 MCM 2 1 9/32 3/8 HSC75-13-T16 HS2C75-13-T16 HS3C75-13-T16 3/4 16 1 Stranded 2/0 Stranded 2 1 3/8 HSC75-21-T16 HS2C75-21-T16 HS3C75-21-T16 3/4 16 2/0 Stranded 4/0 Stranded 2 1 1/8 3/8 HSC75-30-T16 HS2C75-30-T16 HS3C75-30-T16 3/4 16 4/0 Stranded 300 MCM 2 1 9/32 3/8 HSC75-50-T16 HS2C75-50-T16 HS3C75-50-T16 3/4 16 300 MCM 500 MCM 2 1 1/2 3/8 HSC100-13-T14 HS2C100-13-T14 HS3C100-13-T14 1 14 1 Stranded 2/0 Stranded 2 1 3/8 HSC100-21-T14 HS2C100-21-T14 HS3C100-21-T14 1 14 2/0 Stranded 4/0 Stranded 2 1 1/8 3/8 HSC100-30-T14 HS2C100-30-T14 HS3C100-30-T14 1 14 4/0 Stranded 300 MCM 2 1 9/32 3/8 HSC100-50-T14 HS2C100-50-T14 HS3C100-50-T14 1 14 300 MCM 500 MCM 2 1 1/2 3/8 HSC100-75-T14 HS2C100-75-T14 HS3C100-75-T14 1 14 500 MCM 750 MCM 2 1 5/8 3/8 HSC125-21-T12 HS2C125-21-T12 HS3C125-21-T12 1 1/4 12 2/0 Stranded 4/0 Stranded 2 1 1/8 3/8 HSC125-30-T12 HS2C125-30-T12 HS3C125-30-T12 1 1/4 12 4/0 Stranded 300 MCM 2 1 9/32 3/8 HSC125-50-T12 HS2C125-50-T12 HS3C125-50-T12 1 1/4 12 300 MCM 500 MCM 2 1 1/2 3/8 HSC125-75-T12 HS2C125-75-T12 HS3C125-75-T12 1 1/4 12 500 MCM 750 MCM 2 1 5/8 3/8 HSC125-100-T12 HS2C125-100-T12 HS3C125-100-T12 1 1/4 12 750 MCM 1000 MCM 2 3/4 1 15/16 1/2 HSC150-30-T12 HS2C150-30-T12 HS3C150-30-T12 1 1/2 12 4/0 Stranded 300 MCM 2 1 9/32 3/8 HSC150-50-T12 HS2C150-50-T12 HS3C150-50-T12 1 1/2 12 300 MCM 500 MCM 2 1 1/2 3/8 HSC150-75-T12 HS2C150-75-T12 HS3C150-75-T12 1 1/2 12 500 MCM 750 MCM 2 1 5/8 3/8 HSC150-100-T12 HS2C150-100-T12 HS3C150-100-T12 1 1/2 12 750 MCM 1000 MCM 2 3/4 1 15/16 1/2
164 Bronze Stud Connectors © 2011, AFL, all rights reserved. PP-3-00377, Revision 1, 8.5.13 Specifications are subject to change without notice. Bronze Stud Connectors www.AFLglobal.com or 800-890-8878 A H ERCULON ™ variable type connector for joining a cable or a wire to a threaded stud. The stud end of the connector can also be furnished to accommodate a plain stud or pipe. Material Cast Copper Alloy Hardware Everdur bolts, nuts and lockwashers Notes • Other sizes of studs and various threads to the inch can be promptly furnished. • For a 500 MCM cables to a .75" T16 stud at 90° order HSC75-50-90-T16 • For a 500 MCM cable to a .75" T0 stud at 90° order HSC75-50-90-T0 TYPE HSC-90 Copper Stud Connector for Cable or Wire B A HSC-90 Ordering Information CATALOG NUMBER STUD DIA THREADS PER INCH CABLE RANGE DIMENSIONS IN INCHES BOLT SIZE MIN MAX A B HSC50-4-90-T13 1/2 13 8 Solid 4 Stranded 2 5/8 3/8 HSC50-8-90-T13 1/2 13 4 Solid 1 Stranded 2 7/8 3/8 HSC50-13-90-T13 1/2 13 1 Stranded 2/0 Stranded 2 1 3/8 HSC50-21-90-T13 1/2 13 2/0 Stranded 4/0 Stranded 2 1 1/8 3/8 HSC63-13-90-T18 5/8 18 1 Stranded 2/0 Stranded 2 1 3/8 HSC63-21-90-T18 5/8 18 2/0 Stranded 4/0 Stranded 2 1 1/8 3/8 HSC63-30-90-T18 5/8 18 4/0 Stranded 300 MCM 2 1 9/32 3/8 HSC75-13-90-T16 3/4 16 1 Stranded 2/0 Stranded 2 1 3/8 HSC75-21-90-T16 3/4 16 2/0 Stranded 4/0 Stranded 2 1 1/8 3/8 HSC75-30-90-T16 3/4 16 4/0 Stranded 300 MCM 2 1 9/32 3/8 HSC75-50-90-T16 3/4 16 300 MCM 500 MCM 2 1 1/2 3/8 HSC100-13-90-T14 1 14 1 Stranded 2/0 Stranded 2 1 3/8 HSC100-21-90-T14 1 14 2/0 Stranded 4/0 Stranded 2 1 1/8 3/8 HSC100-30-90-T14 1 14 4/0 Stranded 300 MCM 2 1 9/32 3/8 HSC100-50-90-T14 1 14 300 MCM 500 MCM 2 1 1/2 3/8 HSC100-75-90-T14 1 14 500 MCM 750 MCM 2 1 5/8 3/8 HSC125-21-90-T12 1 1/4 12 2/0 Stranded 4/0 Stranded 2 1 1/8 3/8 HSC125-30-90-T12 1 1/4 12 4/0 Stranded 300 MCM 2 1 9/32 3/8 HSC125-50-90-T12 1 1/4 12 300 MCM 500 MCM 2 1 1/2 3/8 HSC125-75-90-T12 1 1/4 12 500 MCM 750 MCM 2 1 5/8 3/8 HSC125-100-90-T12 1 1/4 12 750 MCM 1000 MCM 2 3/4 1 15/16 1/2 HSC150-30-90-T12 1 1/2 12 4/0 Stranded 300 MCM 2 1 9/32 3/8 HSC150-50-90-T12 1 1/2 12 300 MCM 500 MCM 2 1 1/2 3/8 HSC150-75-90-T12 1 1/2 12 500 MCM 750 MCM 2 1 5/8 3/8 HSC150-100-90-T12 1 1/2 12 750 MCM 1000 MCM 2 3/4 1 15/16 1/2
165 Bronze Stud Connectors © 2011, AFL, all rights reserved. PP-3-00387, Revision 1, 9.2.11 Specifications are subject to change without notice. www.AFLglobal.com or 800-890-8878 Bronze Stud Connectors Contact nuts for clamping flat bus bars or terminal pads to threaded studs. For greater contact surface flange nuts, Type NF, provide additional area. Designed to conduct the full rated load of the stud. Large face areas offer a high electrical contact efficiency. All nuts are machined to a high percent full thread to effect maximum thread bearing area. Material Copper Alloy Note • Other numbers of threads per inch can be furnished for any given stud diameter upon specification. TYPE NP, NF Copper Contact Nuts Ordering Information CATALOG NUMBER STUD DIAMETER THREADS PER INCH DIMENSIONS IN INCHES NP NF F T W NP31 NF31 5/16 18 3/4 1/4 5/8 NP38 NF38 3/8 16 7/8 5/16 3/4 NP50 NF50 1/2 13 1 1/8 3/8 7/8 NP62 NF62 5/8 18 1 3/8 1/2 1 1/16 NP75 NF75 3/4 16 1 5/8 5/8 1 1/4 NP87 NF87 7/8 14 1 13/16 11/16 1 3/8 NP100 NF100 1 14 1 15/16 3/4 1 1/2 NP112 NF112 1 1/8 12 2 1/4 13/16 1 3/4 NP125 NF125 1 1/4 12 2 1/2 7/8 2 NP150 NF150 1 1/2 12 2 15/16 15/16 2 3/8 NP175 NF175 1 3/4 12 2 3/8 1 2 11/16 NP200 NF200 2 12 3 3/4 1 1/8 3 NP250 NF250 2 1/2 12 4 9/26 1 1/4 3 11/16 NP300 NF300 3 12 5 3/8 1 1/2 4 5/16 NP350 NF350 3 1/2 12 6 1/4 1 3/4 5 NP400 NF400 4 12 6 3/4 2 5 1/2 NP NF TYPE NP F W T W T TYPE NF
© 2011, AFL, all rights reserved. PP-3-00451, Revision 7, 7.7.2025 Specifications are subject to change without notice. AFLglobal.com | 800.890.8879 166 Bronze Stud Connectors Bronze Stud Connectors continued Material Copper Alloy Hardware Everdur bolts, nuts and lockwashers Note • For a 1" T14 stud, and two 1000 MCM cables order S2CX100-100-T14 TYPE SCX, S2CX Copper Stud Connector for Cable SCX S2CX SCX connects one cable to one stud and S2CX connects two cables on one stud. A variable conductor stud connector which takes a wide range of cable sizes in line or in a 90° position. The reversible cap permits optimum clamping for all cable sizes within the assigned ranges. In addition, one flat surface on SCX can be machined to accommodate flat bar conductors. SCX can be furnished upon request in type SCX-N with bolt holes to accommodate NEMA standard bar drilling. L S2CX SCX C B C
167 Bronze Stud Connectors © 2011, AFL, all rights reserved. PP-3-00451, Revision 7, 7.7.2025 Specifications are subject to change without notice. AFLglobal.com | 800.890.8879 Bronze Stud Connectors Ordering Information CATALOG NUMBERS STUD DIA. THREADS PER INCH CABLE RANGE SPS RANGE DIMENSIONS IN INCHES BOLT SIZE SMALL GROOVE LARGE GROOVE SMALL GROOVE LARGE GROOVE B C L STUD TAP SCX50-21-T13 1/2 13 6 Sol.-1 Stranded 1 Stranded-4/0 - - 2 2 4 5/8 3/8 3/8 SCX75-21-T16 3/4 16 6 Sol.-1 Stranded 1 Stranded-4/0 - - 2 2 4 5/8 3/8 3/8 SCX75-50-T16 3/4 16 6 Solid-4/0 4/0-500 MCM 3/8 1/2 2 2 1/4 4 7/8 3/8 5/8 SCX75-100-T16 3/4 16 2 Solid-350 MCM 350 MCM-1000 MCM 3/8 3/4 2 2 1/2 5 1/8 3/8 3/8 SCX100-50-T12 1 12 6 Solid-4/0 4/0-500 MCM 3/8 1/2 2 2 1/4 4 7/8 3/8 3/8 SCX100-50-T14 1 14 6 Solid-4/0 4/0-500 MCM 3/8 1/2 2 2 1/4 4 7/8 3/8 3/8 SCX100-50-T0 1 0 6 Solid-4/0 4/0-500 MCM 3/8 1/2 2 2 1/4 4 7/8 3/8 3/8 SCX100-100-T12 1 12 2 Solid-350 MCM 350 MCM-1000 MCM 3/8 3/4 2 1/2 2 7/8 6 3/8 1/2 1/2 SCX100-100-T14 1 14 2 Solid-350 MCM 350 MCM-1000 MCM 3/8 3/4 2 1/2 2 7/8 6 3/8 1/2 1/2 SCX112-50-T12 1 1/8 12 6 Solid-4/0 4/0-500 MCM 3/8 1/2 2 2 1/4 4 7/8 3/8 3/8 SCX112-100-T12 1 1/8 12 2 Solid-350 MCM 350 MCM-1000 MCM 3/8 3/4 2 3/4 2 7/8 6 3/8 1/2 1/2 SCX112-200-T12 1 1/8 12 4/0-795 MCM 795 MCM-2000 MCM 3/8 1 1/4 2 3/4 3 3/8 6 3/4 1/2 1/2 SCX118-200-T0 1 3/16 0 4/0-900 MCM 900 MCM-2000 MCM 3/8 1 1/4 2 3/4 3 3/8 6 5/8 1/2 1/2 SCX125-50-T12 1 1/4 12 6 Solid-4/0 4/0-500 MCM 3/8 1/2 2 2 1/4 4 7/8 3/8 3/8 SCX125-100-T12 1 1/4 12 2 Solid-350 MCM 350 MCM-1000 MCM 3/8 3/4 2 3/4 2 7/8 6 3/8 1/2 1/2 SCX125-200-T12 1 1/4 12 2 Solid-350 MCM 900 MCM-2000 MCM 3/8 1 1/4 2 3/4 3 3/8 6 5/8 1/2 1/2 SCX150-50-T12 1 1/2 12 6 Solid-4/0 4/0-500 MCM 3/8 1/2 2 2 1/4 4 7/8 3/8 3/8 SCX150-100-T12 1 1/2 12 2 Solid-350 MCM 350 MCM-1000 MCM 3/8 3/4 2 3/4 2 7/8 6 3/8 1/2 1/2 SCX150-200-T12 1 1/2 12 4/0-900 MCM 900 MCM-2000 MCM 3/8 1 1/4 2 3/4 3 3/8 6 3/4 1/2 1/2 SCX175-50-T12 1 3/4 12 6 Solid-4/0 4/0-500 MCM 3/8 1/2 2 2 1/4 4 5/8 3/8 3/8 SCX175-100-T12 1 3/4 12 2 Solid-350 MCM 350 MCM-1000 MCM 3/8 3/4 2 3/4 2 7/8 6 1/2 1/2 1/2 SCX175-200-T12 1 3/4 12 4/0-900 MCM 900 MCM-2000 MCM 3/8 1 1/4 2 3/4 3 3/8 6 5/8 1/2 1/2 SCX200-50-T12 2 12 6 Solid-4/0 4/0-500 MCM 3/8 1/2 2 1/4 2 1/4 5 1/4 3/8 3/8 SCX200-100-T12 2 12 2 Solid-350 MCM 350 MCM-1000 MCM 3/8 3/4 2 3/4 2 7/8 6 1/2 1/2 SCX200-200-T12 2 12 4/0-900 MCM 900 MCM-2000 MCM 3/8 1 1/4 2 3/4 3 3/8 6 5/8 1/2 1/2 SCX225-50-T12 2 1/4 12 6 Solid-4/0 4/0-500 MCM 3/8 1/2 2 2 1/4 4 5/8 3/8 3/8 SCX225-100-T12 2 1/4 12 2 Solid-350 MCM 350 MCM-1000 MCM 3/8 3/4 2 3/4 2 7/8 6 1/2 1/2 SCX225-200-T12 2 1/4 12 4/0-900 MCM 900 MCM-2000 MCM 3/8 1 1/4 2 3/4 3 3/8 6 5/8 1/2 1/2 SCX250-50-T12 2 1/2 12 6 Solid-4/0 4/0-500 MCM 3/8 1/2 2 2 1/4 4 5/8 3/8 3/8 SCX250-100-T12 2 1/2 12 2 Solid-350 MCM 350 MCM-1000 MCM 3/8 3/4 2 3/4 2 7/8 6 1/2 1/2 SCX250-200-T12 2 1/2 12 4/0-900 MCM 900 MCM-2000 MCM 3/8 1 1/4 2 3/4 3 3/8 6 5/8 1/2 1/2 SCX300-50-T12 3 12 6 Solid-4/0 4/0-500 MCM 3/8 1/2 2 2 1/4 4 5/8 5/8 3/8 SCX300-100-T12 3 12 2 Solid-350 MCM 350 MCM-1000 MCM 3/8 3/4 2 3/4 2 7/8 6 5/8 1/2 SCX300-200-T12 3 12 4/0-900 MCM 900 MCM-2000 MCM 3/8 1 1/4 2 3/4 3 3/8 6 5/8 5/8 1/2 TYPE SCX, S2CX Copper Stud Connector for Cable
168 Bronze Stud Connectors © 2011, AFL, all rights reserved. PP-3-00460, Revision 1, 1.25.18 Specifications are subject to change without notice. Bronze Stud Connectors www.AFLglobal.com or 800-890-8878 A connector for joining a tubular bus conductor to a threaded stud. The stud end can be threaded to any specified number of threads per inch or bored for an unthreaded stud. Material Copper Alloy Hardware Everdur bolts, nuts and lockwashers Notes • For Stud threads not listed, add suffix 'T' and the number of threads per inch to category number. Ex: For a 1 1/8" stud to a 1 1/4" bus, 90°, without threads order SP112-125-T0-90. • For a 1 1/8" stud to a 1 1/4" bus, straight , without threads, order SP112-125-T0. TYPE SP, SP-90 Stud Connector For Tube To Threaded Stud Ordering Information CATALOG NUMBER STUD DIAMETER THREADS PER INCH SPS DIMENSIONS IN INCHES BOLT SIZE SP SP-90 A B C SP50-50-T13 SP50-50-T13-90 1/2 13 1/2 2 1/4 2 2 3/8 SP50-75-T13 SP50-75-T13-90 1/2 13 3/4 2 7/16 2 2 3/8 SP50-10-T13 SP50-10-T13-90 1/2 13 1 2 11/16 2 1/8 2 3/8 SP75-50-T16 SP75-50-T16-90 3/4 16 1/2 2 1/4 2 2 3/8 SP75-75-T16 SP75-75-T16-90 3/4 16 3/4 2 7/16 2 2 3/8 SP75-100-T16 SP75-100-T16-90 3/4 16 1 2 11/16 2 1/8 2 3/8 SP75-125-T16 SP75-125-T16-90 3/4 16 1 1/4 3 7/16 2 1/2 2 1/4 1/2 SP75-150-T16 SP75-150-T16-90 3/4 16 1 1/2 3 5/8 2 5/8 2 1/4 1/2 SP100-50-T14 SP100-50-T14-90 1 14 1/2 2 1/4 2 2 3/8 SP100-75-T14 SP100-75-T14-90 1 14 3/4 2 7/16 2 2 3/8 SP100-100-T14 SP100-100-T14-90 1 14 1 2 11/16 2 1/8 2 3/8 SP100-125-T14 SP100-125-T14-90 1 14 1 1/4 3 7/16 2 1/2 2 1/4 1/2 SP100-150-T14 SP100-150-T14-90 1 14 1 1/2 3 5/8 2 5/8 2 1/4 1/2 SP100-200-T14 SP100-200-T14-90 1 14 2 4 1/8 2 3/4 2 1/4 1/2 SP112-50-T12 SP112-50-T12-90 1 1/8 12 1/2 2 1/4 2 2 3/8 SP112-75-T12 SP112-75-T12-90 1 1/8 12 3/4 2 7/16 2 2 3/8 SP112-100-T12 SP112-100-T12-90 1 1/8 12 1 2 11/16 2 1/8 2 3/8 SP112-125-T12 SP112-125-T12-90 1 1/8 12 1 1/4 3 7/16 2 1/2 2 1/4 1/2 SP125-200-T12 SP125-200-T12-90 1 1/4 12 2 4 1/8 2 3/4 2 3/4 1/2 SP SP-90 C SP SP-90 B A A B C
169 Bronze Stud Connectors © 2011, AFL, all rights reserved. PP-3-00465, Revision 1, 1.13.14 Specifications are subject to change without notice. www.AFLglobal.com or 800-890-8878 Bronze Stud Connectors An expansion stud connector for joining a tubular bus to a threaded or unthreaded, transformer or terminal, stud. The movements of the conductors caused by thermal expansion and contraction or settling foundations are efficiently absorbed by the flexible braided linkages. Type SX is furnished with an alignment guide for connections where axial alignment is required. Material Stud - Copper Alloy Bus - Aluminum Alloy Hardware See image Notes For a 90 degree stud connector add -90 to the Catalog Number. EX. For at 1"-T14 stud to 1in SPS connector with 90 degree stud connector order: SX100-100A-T14-90 TYPE SX-A, SX-A-90 Stud Expansion Connector for Pipe Both SX-A and SX-A-90 connect copper stud to aluminum bus. SX-A Ordering Information CATALOG NUMBER STUD DIAMETER THREADS PER INCH SPS FIG. NO. DIMENSIONS IN INCHES BOLT SIZE A B STUD PIPE SX100-200A-T14 1 14 2 1 2 3/4 3 1/4 1/2 1/2 SX112-100A-T12 1 1/8 12 1 1 2 3 1/8 3/8 1/2 SX112-200A-T12 1 1/8 12 2 1 2 3/4 3 1/4 1/2 1/2 SX150-150A-T12 1 1/2 12 1 1/2 1 2 3/4 3 1/4 1/2 1/2 SX150-200A-T12 1 1/2 12 2 1 2 3/4 3 1/4 1/2 1/2 SX150-300A-T12 2 12 3 2 2 3/4 3 1/2 1/2 5/8 SX200-350A-T12 2 12 3 1/2 2 2 3/4 3 1/2 1/2 5/8 SX200-400A-T12 2 12 4 2 2 3/4 3 1/2 1/2 5/8 SX250-300A-T12 2 1/2 12 3 2 2 3 1/2 1/2 5/8 FIG. 1 B B TINNED COPPER BRAIDS TINNED FERRULE (TYP.) BOLTS, NUTS, FLAT AND LOCK WASHERS EVERDUR FIG. 2 BOLTS, NUTS, FLAT AND LOCK WASHERS STAINLESS STEEL BOLTS, NUTS, FLAT AND LOCK WASHERS ALUM A 6 MIN SX-A BOLTS, NUTS, FLAT AND LOCK WASHERS EVERDUR SX-A-90
170 Bronze Stud Connectors © 2011, AFL, all rights reserved. P-3-00464, Revision 3, 1.25.18 Specifications are subject to change without notice. Bronze Stud Connectors www.AFLglobal.com or 800-890-8878 An expansion stud connector for joining a tubular bus to a threaded or unthreaded transformer stud. The movements of the conductors caused by thermal expansion and contraction or settling foundations are efficiently absorbed by the flexible braided linkages. Type SX is furnished with an alignment guide for connections where axial alignment is required. SXP does not have an alignment guide. Material Copper Alloy Hardware Everdur bolts, nuts and lockwashers TYPE SX, SX-90, SXP Stud Expansion Connector for Pipe SX A E D TINNED COPPER BRAIDS SX-90 Notes • For a 90 degree stud connector, add -90 to the Catalog Number. EX. For a 1"-T14 stud to 1" SPS connector with 90 degree stud connector, order: SX100-100-T14-90. • SXP has no alignment guide. EX. For a 1"-T14 stud to 1" SPS connector with no alignment guide connector, order: SXP100-100-T14. • For Tin Dipped, add -SN to the Catalog Number: SX100-100-T14-SN. • For Laminates in place of Braids, add "L" to the Catalog Number: SXL150-125-T12. • For stud threads not listed, add suffix "T" and the number of threads per inch to catalog number. EX. For a 1" stud to 1" SPS connector with no threads order: SX100-100-T0.
171 Bronze Stud Connectors © 2011, AFL, all rights reserved. P-3-00464, Revision 3, 1.25.18 Specifications are subject to change without notice. www.AFLglobal.com or 800-890-8878 Bronze Stud Connectors TYPE SX, SX-90, SXP Stud Expansion Connector for Pipe Ordering Information CATALOG NUMBER STUD DIA THREADS PER INCH SPS DIMENSIONS IN INCHES BOLT SIZE SX SX-90 SXP A D E STUD SPS SX75-75-T16 SX75-75-T16-90 SXP75-75-T16 3/4 16 3/4 2 1/4 6 5/8 1 1/2 1/2 1/2 SX75-100-T16 SX75-100-T16-90 SXP75-100-T16 3/4 16 1 2 1/4 6 3/4 1 1/2 1/2 1/2 SX100-75-T14 SX100-75-T14-90 SXP100-75-T14 1 14 3/4 2 1/4 6 5/8 1 1/2 1/2 1/2 SX100-100-T14 SX100-100-T14-90 SXP100-100-T14 1 14 1 2 1/4 6 3/4 1 1/2 1/2 1/2 SX100-125-T14 SX100-125-T14-90 SXP100-125-T14 1 14 1 1/4 2 1/4 7 5/8 1 1/2 1/2 1/2 SX100-150-T14 SX100-150-T14-90 SXP100-150-T14 1 14 1 1/2 2 1/4 7 5/8 1 1/2 1/2 1/2 SX112-75-T12 SX112-75-T12-90 SXP112-75-T12 1 1/8 12 3/4 2 1/4 6 5/8 1 1/2 1/2 1/2 SX112-100-T12 SX112-100-T12-90 SXP112-100-T12 1 1/8 12 1 2 1/4 6 3/4 1 1/2 1/2 1/2 SX112-125-T12 SX112-125-T12-90 SXP112-125-T12 1 1/8 12 1 1/4 2 1/4 7 5/8 1 1/2 1/2 1/2 SX112-150-T12 SX112-150-T12-90 SXP-112-150-T12 1 1/8 12 1 1/2 2 1/4 7 5/8 1 1/2 1/2 1/2 SX125-75-T12 SX125-75-T12-90 SXP125-75-T12 1 1/4 12 3/4 2 3/4 6 5/8 1 1/2 1/2 1/2 SX125-100-T12 SX125-100-T12-90 SXP125-100-T12 1 1/4 12 1 2 3/4 6 3/4 1 1/2 1/2 1/2 SX125-125-T12 SX125-125-T12-90 SXP125-125-T12 1 1/4 12 1 1/4 2 3/4 7 5/8 1 1/2 1/2 1/2 SX125-150-T12 SX125-150-T12-90 SXP125-150-T12 1 1/4 12 1 1/2 2 3/4 7 5/8 1 1/2 1/2 1/2 SX125-200-T12 SX125-200-T12-90 SXP125-200-T12 1 1/4 12 2 2 3/4 8 1/4 1 1/2 1/2 1/2 SX150-75-T12 SX150-75-T12-90 SXP150-75-T12 1 1/2 12 3/4 2 3/4 6 5/8 1 1/2 1/2 1/2 SX150-100-T12 SX150-100-T12-90 SXP150-100-T12 1 1/2 12 1 2 3/4 6 3/4 1 1/2 1/2 1/2 SX150-125-T12 SX150-125-T12-90 SXP150-125-T12 1 1/2 12 1 1/4 2 3/4 7 5/8 1 1/2 1/2 1/2 SX150-150-T12 SX150-150-T12-90 SXP150-150-T12 1 1/2 12 1 1/2 2 3/4 7 5/8 1 1/2 1/2 1/2 SX150-200-T12 SX150-200-T12-90 SXP150-200-T12 1 1/2 12 2 2 3/4 8 1/4 2 1/2 1/2 1/2 SX175-75-T12 SX175-75-T12-90 SXP175-75-T12 1 3/4 12 3/4 2 3/4 6 5/8 1 1/2 1/2 1/2 SX175-100-T12 SX175-100-T12-90 SXP175-100-T12 1 3/4 12 1 2 3/4 6 3/4 1 1/2 1/2 1/2 SX175-125-T12 SX175-125-T12-90 SXP175-125-T12 1 3/4 12 1 1/4 2 3/4 7 5/8 1 1/2 1/2 1/2 SX175-150-T12 SX175-150-T12-90 SXP175-150-T12 1 3/4 12 1 1/2 2 3/4 7 5/8 2 1/2 1/2 1/2 SX175-200-T12 SX175-200-T12-90 SXP175-200-T12 1 3/4 12 2 2 3/4 8 1/4 2 1/2 1/2 1/2 SX200-100-T12 SX200-100-T12-90 SXP200-100-T12 2 12 1 2 3/4 6 3/4 1 1/2 1/2 1/2 SX200-125-T12 SX200-125-T12-90 SXP200-125-T12 2 12 1 1/4 2 3/4 7 5/8 1 1/2 1/2 1/2 SX200-150-T12 SX200-150-T12-90 SXP200-150-T12 2 12 1 1/2 2 3/4 7 5/8 1 1/2 1/2 1/2 SX200-200-T12 SX200-200-T12-90 SXP200-200-T12 2 12 2 2 3/4 8 1/4 2 1/2 1/2 1/2 SX200-250-T12 SX200-250-T12-90 SXP200-250-T12 2 12 2 1/2 2 3/4 8 3/4 2 1/2 1/2 1/2 SX225-350E-T12 SX225-350E-T12-90 SXP225-350E-T12 2 1/4 12 3 1/2 2 3/4 9 1/4 2 1/2 1/2 5/8 SX300-200-T12 SX300-200-T12-90 SXP300-200-T12 3 12 2 3 1/4 8 1/4 2 1/2 5/8 1/2 SX300-250-T12 SX300-250-T12-90 SXP300-250-T12 3 12 2 1/2 3 1/4 8 3/4 2 1/2 5/8 1/2 SX300-300-T12 SX300-300-T12-90 SXP300-300-T12 3 12 3 3 1/4 10 2 1/2 5/8 5/8 SX300-350-T12 SX300-350-T12-90 SXP300-350-T12 3 12 3 1/2 3 1/4 11 2 1/2 5/8 5/8 SX300-400-T12 SX300-400-T12-90 SXP300-400-T12 3 12 4 3 1/4 11 1/2 2 1/2 5/8 5/8
172 Bronze Stud Connectors © 2011, AFL, all rights reserved. PP-3-00513, Revision 0, 3.10.11 Specifications are subject to change without notice. Bronze Stud Connectors www.AFLglobal.com or 800-890-8878 Material Copper Alloy Hardware Everdur bolts, nuts, lockwashers, and U-bolts Notes • Can also be readily furnished for plain unthreaded studs. • For a 90 degree add -90 and for double connector change 'US' to 'U2S' • For a 1/2" stud, 2/0 Str cable, and 90 degree angle order: US50-13-T13-90 • For a 1/2" stud, two 2/0 Str cable, and 90 degree angle order: U2S50-13-T13-90 • For a 1/2" stud, two 2/0 Str cables and no thread order: U2S50-13-T0 TYPE US, U2S, US-90, U2S-90 Copper U-bolt Stud Connector For Cable US U2S US-90 U2S-90 L US-90 U2S US C U2S-90
173 Bronze Stud Connectors © 2011, AFL, all rights reserved. PP-3-00513, Revision 0, 3.10.11 Specifications are subject to change without notice. www.AFLglobal.com or 800-890-8878 Bronze Stud Connectors TYPE US, U2S, US-90, U2S-90 Copper U-bolt Stud Connector For Cable Ordering Information CATALOG NUMBER STUD DIA. THREADS PER INCH CABLE RANGE DIMENSIONS IN INCHES BOLT SIZE STAIGHT 90 DEGREES 1 CABLE 2 CABLES 1 CABLE 2 CABLES MIN MAX C L STUD CABLE US50-13-T13 U2S50-13-T13 US50-13-T13-90 U2S50-13-T13-90 1/2 13 6 STR 2/0 STR 2 4 3/4 3/8 5/16 US50-21-T13 U2S50-21-T13 US50-21-T13-90 U2S50-21-T13-90 1/2 13 1 STR 4/0 STR 2 4 7/8 3/8 3/8 US62-13-T18 U2S62-13-T18 US62-13-T18-90 U2S62-13-T18-90 5/8 18 6 STR 2/0 STR 2 4 3/4 3/8 5/16 US62-21-T18 U2S62-21-T18 US62-21-T18-90 U2S62-21-T18-90 5/8 18 1 STR 4/0 STR 2 4 7/8 3/8 3/8 US62-30-T18 U2S62-30-T18 US62-30-T18-90 U2S62-30-T18-90 5/8 18 1/0 STR 300 MCM 2 5 3/8 3/8 US75-13-T16 U2S75-13-T16 US75-13-T16-90 U2S75-13-T16-90 3/4 16 6 STR 2/0 STR 2 4 3/4 3/8 5/16 US75-21-T16 U2S75-21-T16 US75-21-T16-90 U2S75-21-T16-90 3/4 16 1 STR 4/0 STR 2 4 7/8 3/8 3/8 US75-30-T16 U2S75-30-T16 US75-30-T16-90 U2S75-30-T16-90 3/4 16 1/0 STR 300 MCM 2 5 3/8 3/8 US75-50-T16 U2S75-50-T16 US75-50-T16-90 U2S75-50-T16-90 3/4 16 300 MCM 500 MCM 2 3/4 5 1/4 3/8 3/8 US100-21-T14 U2S100-21-T14 US100-21-T14-90 U2S100-21-T14-90 1 14 1 STR 4/0 STR 2 4 7/8 3/8 3/8 US100-30-T14 U2S100-30-T14 US100-30-T14-90 U2S100-30-T14-90 1 14 1/0 STR 300 MCM 2 3/4 5 3/8 3/8 US100-50-T14 U2S100-50-T14 US100-50-T14-90 U2S100-50-T14-90 1 14 300 MCM 500 MCM 2 5 1/4 3/8 3/8 US100-80-T14 U2S100-80-T14 US100-80-T14-90 U2S100-80-T14-90 1 14 500 MCM 800 MCM 2 3/4 6 1/4 1/2 1/2 US125-30-T12 U2S125-30-T12 US125-30-T12-90 U2S125-30-T12-90 1 1/4 12 1/0 STR 300 MCM 2 5 3/8 3/8 US125-50-TI2 U2S125-50-TI2 US125-50-TI2-90 U2S125-50-TI2-90 1 1/4 12 300 MCM 500 MCM 2 5 1/4 3/8 3/8 US125-80-T12 U2S125-80-T12 US125-80-T12-90 U2S125-80-T12-90 1 1/4 12 500 MCM 800 MCM 2 3/4 6 1/4 1/2 1/2 US125-100-T12 U2S125-100-T12 US125-100-T12-90 U2S125-100-T12-90 1 1/4 12 750 MCM 1000 MCM 2 3/4 6 1/2 1/2 1/2 US150-30-T12 U2S150-30-T12 US150-30-T12-90 U2S150-30-T12-90 1 1/2 12 1/0 STR 300 MCM 2 5 3/8 3/8 US150-80-T12 U2S150-80-T12 US150-80-T12-90 U2S150-80-T12-90 1 1/2 12 500 MCM 800 MCM 2 3/4 6 1/4 1/2 1/2 US150-100-T12 U2S150-100-T12 US150-100-T12-90 U2S150-100-T12-90 1 1/2 12 750 MCM 1000 MCM 2 3/4 6 1/2 1/2 1/2 US150-150-TI2 U2S150-150-TI2 US150-150-TI2-90 U2S150-150-TI2-90 1 1/2 12 1000 MCM 1500 MCM 2 3/4 7 1/2 1/2 US150-200-T12 U2S150-200-T12 US150-200-T12-90 U2S150-200-T12-90 1 1/2 12 1500 MCM 2000 MCM 2 3/4 7 1/2 1/2 1/2 US200-50-T12 U2S200-50-T12 US200-50-T12-90 U2S200-50-T12-90 2 12 300 MCM 500 MCM 2 5 1/4 3/8 3/8 US200-80-T12 U2S200-80-T12 US200-80-T12-90 U2S200-80-T12-90 2 12 500 MCM 800 MCM 2 3/4 6 1/4 1/2 1/2 US200-100-T12 U2S200-100-T12 US200-100-T12-90 U2S200-100-T12-90 2 12 750 MCM 1000 MCM 2 3/4 6 1/2 1/2 1/2 US200-150-T12 U2S200-150-T12 US200-150-T12-90 U2S200-150-T12-90 2 12 1000 MCM 1500 MCM 2 3/4 7 1/2 1/2 US200-200-T12 U2S200-200-T12 US200-200-T12-90 U2S200-200-T12-90 2 12 1500 MCM 2000 MCM 2 3/4 7 1/2 1/2 1/2 US250-50-T12 U2S250-50-T12 US250-50-T12-90 U2S250-50-T12-90 2 1/2 12 300 MCM 500 MCM 2 5 1/4 3/8 3/8 US250-80-TI2 U2S250-80-TI2 US250-80-TI2-90 U2S250-80-TI2-90 2 1/2 12 500 MCM 800 MCM 2 3/4 6 1/4 1/2 1/2 US250-100-T12 U2S250-100-T12 US250-100-T12-90 U2S250-100-T12-90 2 1/2 12 750 MCM 1000 MCM 2 3/4 6 1/2 1/2 1/2 US250-150-TI2 U2S250-150-TI2 US250-150-TI2-90 U2S250-150-TI2-90 2 1/2 12 1000 MCM 1500 MCM 2 3/4 7 1/2 1/2 US300-50-T12 U2S300-50-T12 US300-50-T12-90 U2S300-50-T12-90 3 12 300 MCM 500 MCM 2 5 1/4 3/8 3/8 US300-80-T12 U2S300-80-T12 US300-80-T12-90 U2S300-80-T12-90 3 12 500 MCM 800 MCM 3 6 1/2 1/2 1/2 US300-100-T12 U2S300-100-T12 US300-100-T12-90 U2S300-100-T12-90 3 12 750 MCM 1000 MCM 3 6 3/4 1/2 1/2 US300-150-T12 U2S300-150-T12 US300-150-T12-90 U2S300-150-T12-90 3 12 1000 MCM 1500 MCM 3 7 1/4 1/2 1/2 US300-200-T12 U2S300-200-T12 US300-200-T12-90 U2S300-200-T12-90 3 12 1500 MCM 2000 MCM 3 7 3/4 1/2 1/2
Caractéristiques :
- Alliage de bronze
- Quincaillerie Everdur
- Répond aux normes de la NEMA CC1
Les applications:
- Conçu pour 230 kV
- Sous-station
- Goujon en cuivre au câble
Le connecteur de goujon est conçu pour être utilisé sur des goujons en aluminium. Le connecteur de câble est doté d'une rainure universelle qui permet de choisir un conducteur en cuivre pour chaque taille.
Coupleurs de compression en aluminium 230 kV,Connecteurs en T à compression en aluminium 230 kV,Connecteurs à compression en aluminium de 230 kV,Coupleurs de tube de bus soudés en aluminium de 230 kV,Coudes de tubes bus soudés en aluminium 230 kV,Supports de tubes bus soudés en aluminium de 230 kV,Connecteurs en té et en V en aluminium soudé pour barres de 230 kV,Connecteurs de barres d'alimentation soudées en aluminium de 230 kV,Coupleurs soudés en aluminium pour bus de 230 kV entre tuyaux et câbles,Té soudé en aluminium pour tube de bus de 230 kV vers câble,Terminal de câble soudé en aluminium 230 kV,Bouchons d'extrémité soudés en aluminium de 230 kV,Tige de mise à la terre soudée en aluminium de 230 kV,Robinets à tube soudé en aluminium de 230 kV
370
Close
Connecteurs de câbles à goujons en bronze 230 kV
Caractéristiques :
- Alliage de bronze
- Quincaillerie Everdur
- Répond aux normes de la NEMA CC1
Les applications:
- Conçu pour 230 kV
- Sous-station
- Goujon en cuivre au câble